Effects of Regeneration Heat Exchanger on Entropy, Electricity Cost, and Environmental Pollution Produced by Micro Gas Turbine System

A new method has been employed in this research that optimizes a power generation system by maximizing the first and second law efficiencies and minimizing the entropy generation. Mass flow rates of pollutants and related external social cost of air pollution have been considered in estimating the electricity production cost. The effects of regenerative and CHP heat exchangers on power production, efficiencies, and production cost have been evaluated. The results show that a single regenerative heat exchanger lowers NOx, CO, and CO2 emissions by 15%, 40%, and 0.4%, respectively, and decreases the electricity production cost by nearly 18%. A single CHP heat exchanger has little influence on concentrations of NOx, CO, and CO2 but lowers the electricity production cost by about 36%. It has also been concluded that the values of entropy generation and power output are not much affected by the CHP heat exchanger but the regenerative heat exchanger lowers the values of power output by nearly 8%. A combination of regenerative and CHP heat exchangers decreases the electricity production cost by more than 50%.

[1]  Ibrahim Dincer,et al.  Thermodynamic analysis of reheat cycle steam power plants , 2001 .

[2]  Q. L. Chen,et al.  A new exergoeconomic approach for analysis and optimization of energy systems , 1997 .

[3]  Electo Eduardo Silva Lora,et al.  Biodiesel fuel in diesel micro-turbine engines: Modelling and experimental evaluation , 2008 .

[4]  J. Hawkins Cost Accounting: A Managerial Emphasis , 2006 .

[5]  M. A. Ehyaei,et al.  Energy, economic and environmental (3E) analysis of a micro gas turbine employed for on-site combined heat and power production , 2010 .

[6]  Hongguang Jin,et al.  A novel gas turbine cycle with hydrogen-fueled chemical-looping combustion , 2000 .

[7]  Henry Cohen,et al.  Gas turbine theory , 1973 .

[8]  Osman A. Hamed,et al.  Thermoeconomic analysis of a power/water cogeneration plant , 2006 .

[9]  Mohammad Ameri,et al.  Thermodynamic analysis of a tri-generation system based on micro-gas turbine with a steam ejector refrigeration system , 2010 .

[10]  Miguel A. Lozano,et al.  Theory of the exergetic cost , 1993 .

[11]  F. J. Wang,et al.  Integration of steam injection and inlet air cooling for a gas turbine generation system , 2004 .

[12]  George Tsatsaronis,et al.  Exergy Costing in Exergoeconomics , 1993 .

[13]  Christos A. Frangopoulos,et al.  Thermo-economic functional analysis and optimization , 1987 .

[14]  Kousuke Nishida,et al.  Regenerative steam-injection gas-turbine systems , 2005 .

[15]  Ibrahim Dincer,et al.  Exergy analysis of a thermal power plant with measured boiler and turbine losses , 2010 .

[16]  P. Lettieri,et al.  An introduction to heat transfer , 2007 .

[17]  Ibrahim Dincer,et al.  Efficiency analysis of a cogeneration and district energy system , 2005 .

[18]  George Tsatsaronis,et al.  Exergoeconomic evaluation and optimization of energy systems — application to the CGAM problem , 1994 .

[19]  N. K. Rizk,et al.  Semianalytical Correlations for NOx, CO, and UHC Emissions , 1993 .

[20]  Paolo Iora,et al.  Bottoming micro-Rankine cycles for micro-gas turbines , 2007 .

[21]  José Luz Silveira,et al.  Thermoeconomic analysis method for optimization of combined heat and power systems , 2000 .

[22]  Mohammad Ameri,et al.  Exergy analysis of a 420 MW combined cycle power plant , 2008 .

[23]  Chia-Chin Chuang,et al.  Engineering design and exergy analyses for combustion gas turbine based power generation system , 2004 .

[24]  Andrea Toffolo,et al.  Energy, economy and environment as objectives in multi-criterion optimization of thermal systems design , 2004 .

[25]  I Potts,et al.  Integrated distributed energy evaluation software (IDEAS) simulation of a micro-turbine based CHP system , 2007 .

[26]  B. Field Environmental Economics: An Introduction , 1979 .

[27]  H. Auracher Thermal design and optimization , 1996 .

[28]  Ho-Young Kwak,et al.  Exergoeconomic analysis of gas turbine cogeneration systems , 2001 .

[29]  Ho-Young Kwak,et al.  Exergoeconomic analysis of thermal systems , 1998 .

[30]  R. Kehlhofer,et al.  Combined-cycle gas and steam turbine power plants. 2. edition , 1991 .

[31]  Silvia A. Nebra,et al.  Basic chemically recuperated gas turbines—power plant optimization and thermodynamics second law analysis , 2004 .

[32]  Sanjay,et al.  Comparative performance analysis of cogeneration gas turbine cycle for different blade cooling means , 2009 .

[33]  Sergio A. A. G. Cerqueira,et al.  Thermoeconomic Evaluation of a Gas Turbine Cogeneration System , 1998, Advanced Energy Systems.

[34]  Mohammad Ameri,et al.  Energy, exergy and exergoeconomic analysis of a steam power plant: A case study , 2009 .

[35]  Sergio A. A. G. Cerqueira,et al.  Cost attribution methodologies in cogeneration systems , 1999 .

[36]  Abdul Khaliq,et al.  Exergy analysis of gas turbine trigeneration system for combined production of power heat and refrigeration , 2009 .

[37]  M. Ehyaei,et al.  Optimisation of micro gas turbine by exergy, economic and environmental (3E) analysis , 2010 .

[38]  Ibrahim Dincer,et al.  Potential use of cold thermal energy storage systems for better efficiency and cost effectiveness , 2010 .

[39]  N. Rizk,et al.  Semianalytical Correlations for NOx, CO, and UHC Emissions , 1992 .

[40]  Antonio Valero,et al.  Application of the exergetic cost theory to the CGAM problem , 1994 .

[41]  R. Ganguly,et al.  Energy and exergy analyses of an externally fired gas turbine (EFGT) cycle integrated with biomass gasifier for distributed power generation , 2010 .