Low temperature treatment of domestic sewage in upflow anaerobic sludge blanket and anaerobic hybrid reactors

The treatment of sewage at a temperature of 13°C was investigated in three reactors (each 3.84 litre) a UASB and two anaerobic hybrid (AH) reactors with small sludge granules with an average diameter of 0.73 mm. The media used in the AH reactors were vertical polyurethane foam sheets. The reactors were operated at a HRT of 8 h. The use of small sludge granules and operating the reactors at low upflow velocity (1.8 m/d) improved suspended COD removal efficiencies for the UASB reactor. Moreover, the use of sheets in the AH reactors significantly increased suspended COD removal efficiencies as compared to the UASB and reached to 87% for pre-settled sewage treatment. The treatment of pre-settled sewage instead of raw sewage in AH reactors significantly increased colloidal and dissolved COD removal efficiencies with 13% and 12% respectively and colloidal COD removal efficiency for the UASB reactor with 13%. At ‘steady state’ for pre-settled sewage treatment, the AH reactors removed 64% of the total COD which is significantly higher by 4% than the UASB reactor. Therefore, the anaerobic treatment of domestic sewage at low temperature can be improved by treating pre-settled sewage in shallow AH reactors containing small sludge granules.

[1]  Sonia Maria Manso Vieira,et al.  Discussion Report on Reactor Design of Anaerobic Filters and Sludge Bed Reactors , 1991 .

[2]  A. Stams,et al.  Role of substrate concentration in particle size distribution of methanogenic granular sludge in UASB reactors , 1991 .

[3]  G Lettinga,et al.  Anaerobic treatment of raw domestic sewage at ambient temperatures using a granular bed UASB reactor , 1983, Biotechnology and bioengineering.

[4]  W. M. Wiegant,et al.  Anaerobic Treatment of Domestic Sewage and Wastewater , 1993 .

[5]  M. Stenstrom,et al.  Treatment of low strength domestic wastewater using the anaerobic filter , 1983 .

[6]  Gatze Lettinga,et al.  Anaerobic treatment of domestic sewage under moderate climatic (Dutch) conditions using upflow reactors at increased superficial velocities. , 1992 .

[7]  Gatze Lettinga,et al.  Sustainable integrated biological wastewater treatment , 1996 .

[8]  Marcos Eduardo de Souza,et al.  Development of Technology for the Use of the UASB Reactor in Domestic Sewage Treatment , 1986 .

[9]  M. J. Carter,et al.  Micro semi-automated analysis of surface and wastewaters for chemical oxygen demand. , 1975, Analytical chemistry.

[10]  Fernando Fdz-Polanco,et al.  Low temperature treatment of municipal sewage in anaerobic fluidized bed reactors , 1990 .

[11]  Gatze Lettinga,et al.  Anaerobic treatment of raw sewage at lower temperatures , 1983 .

[12]  Jules B. van Lier,et al.  High-rate anaerobic treatment of malting waste water in a pilot-scale EGSB system under psychrophilic conditions. , 1997 .