Invasive and noninvasive monitoring for early recognition and treatment of shock in high-risk trauma and surgical patients.

The proposed noninvasive monitoring systems provide the essential hemodynamic and oxygen transport information previously available only by invasive thermodilution catheters. More importantly, the noninvasive systems provide continuous on-line real-time displays of data which allow immediate recognition of circulatory abnormalities and provide a means to titrate therapy to appropriate therapeutic goals. The noninvasive systems are easy to apply, safe, inexpensive, and more cost-effective than invasive monitoring.

[1]  W. Shoemaker,et al.  Relationship between supranormal circulatory values, time delays, and outcome in severely traumatized patients , 1993, Critical care medicine.

[2]  H. Engel,et al.  Evaluation of prognostic indices based on hemodynamic and oxygen transport variables in shock patients with adult respiratory distress syndrome , 1987, Critical care medicine.

[3]  Hun H. Sun,et al.  Hemodynamic monitoring by impedance cardiography with an improved signal processing technique , 1993, Proceedings of the 15th Annual International Conference of the IEEE Engineering in Medicine and Biology Societ.

[4]  C. Furberg,et al.  Propranolol-induced lipid changes and their prognostic significance after a myocardial infarction: the Beta-Blocker Heart Attack Trial experience. , 1990, The American journal of cardiology.

[5]  K. Tremper,et al.  Effects of hypoxia and shock on transcutaneous Po2 values in dogs , 1979, Critical care medicine.

[6]  W. Shoemaker,et al.  Noninvasive estimations of cardiac output and circulatory dynamics in critically ill patients , 1995 .

[7]  William C. Shoemaker,et al.  Multicenter trial of a new thoracic electrical bioimpedance device for cardiac output estimation , 1994, Critical care medicine.

[8]  E. Moore,et al.  Incommensurate oxygen consumption in response to maximal oxygen availability predicts postinjury multiple organ failure. , 1991, Journal of Trauma.

[9]  R. P. Noble,et al.  Studies of the circulation in clinical shock , 1943 .

[10]  K. Tremper,et al.  Dermal Heat Transport Analysis for Transcutaneous O2 Measurement , 1978, Acta anaesthesiologica Scandinavica. Supplementum.

[11]  E. Faragher,et al.  Use of survivors' cardiorespiratory values as therapeutic goals in septic shock. , 1989, Critical care medicine.

[12]  W. Shoemaker,et al.  Hemodynamic and oxygen transport patterns for outcome prediction, therapeutic goals, and clinical algorithms to improve outcome. Feasibility of artificial intelligence to customize algorithms. , 1992, Chest.

[13]  X. Wang,et al.  Time-frequency distribution technique in biological signal processing. , 1995, Biomedical instrumentation & technology.

[14]  J. Edwards,et al.  Hemodynamic and oxygen transport variables in cardiogenic shock secondary to acute myocardial infarction, and response to treatment. , 1990, The American journal of cardiology.

[15]  T. Scalea,et al.  Geriatric blunt multiple trauma: improved survival with early invasive monitoring. , 1988, The Journal of trauma.

[16]  E. Rackow,et al.  Elevation of cardiac output and oxygen delivery improves outcome in septic shock. , 1992, Chest.

[17]  E. Bennett,et al.  A randomized clinical trial of the effect of deliberate perioperative increase of oxygen delivery on mortality in high-risk surgical patients. , 1993, JAMA.

[18]  K. Tremper,et al.  TRANSCUTANEOUS OXYGEN MONITORING DURING RESPIRATORY FAILURE, CARDIAC DECOMPENSATION, CARDIAC ARREST, AND CPR , 1980 .

[19]  F. Cerra,et al.  Preoperative optimization of cardiovascular hemodynamics improves outcome in peripheral vascular surgery. A prospective, randomized clinical trial. , 1991, Annals of surgery.

[20]  Philip Smith,et al.  Effect of maximizing oxygen delivery on morbidity and mortality rates in critically ill patients: A prospective, randomized, controlled study , 1993, Critical care medicine.

[21]  W. Shoemaker,et al.  Prospective, randomized trial of survivor values of cardiac index, oxygen delivery, and oxygen consumption as resuscitation endpoints in severe trauma. , 1995, The Journal of trauma.

[22]  K. Tremper,et al.  Continuous transcutaneous oxygen monitoring during respiratory failure, cardiac decompensation, cardiac arrest, and CPR: Transcutaneous oxygen monitoring during arrest and CPR , 1980, Critical care medicine.

[23]  W. Shoemaker,et al.  Prospective trial of supranormal values of survivors as therapeutic goals in high-risk surgical patients. , 1988, Chest.