Design and validation of a computer-based sleep-scoring algorithm

A computer-based sleep scoring algorithm was devised for the real time scoring of sleep-wake state in Wistar rats. Electroencephalogram (EEG) amplitude (microV(rms)) was measured in the following frequency bands: delta (delta; 1.5-6 Hz), theta (Theta; 6-10 Hz), alpha (alpha; 10.5-15 Hz), beta (beta; 22-30 Hz), and gamma (gamma; 35-45 Hz). Electromyographic (EMG) signals (microV(rms)) were recorded from the levator auris longus (neck) muscle, as this yielded a significantly higher algorithm accuracy than the spinodeltoid (shoulder) or temporalis (head) muscle EMGs (ANOVA; P=0.009). Data were obtained using either tethers (n=10) or telemetry (n=4). We developed a simple three-step algorithm that categorizes behavioural state as wake, non-rapid eye movement (NREM) sleep, rapid eye movement (REM) sleep, based on thresholds set during a manually-scored 90-min preliminary recording. Behavioural state was assigned in 5-s epochs. EMG amplitude and ratios of EEG frequency band amplitudes were measured, and compared with empirical thresholds in each animal.STEP 1: EMG amplitude greater than threshold? Yes: "active" wake, no: sleep or "quiet" wake. STEP 2: EEG amplitude ratio (delta x alpha)/(beta x gamma) greater than threshold? Yes: NREM, no: REM or "quiet" wake. STEP 3: EEG amplitude ratio Theta(2)/(delta x alpha) greater than threshold? Yes: REM, no: "quiet" wake. The algorithm was validated with one, two and three steps. The overall accuracy in discriminating wake and sleep (NREM and REM combined) using step one alone was found to be 90.1%. Overall accuracy using the first two steps was found to be 87.5% in scoring wake, NREM and REM sleep. When all three steps were used, overall accuracy in scoring wake, NREM and REM sleep was determined to be 87.9%. All accuracies were derived from comparisons with unequivocally-scored epochs from four 90-min recordings as defined by an experienced human rater. The algorithms were as reliable as the agreement between three human scorers (88%).

[1]  M. Radulovački,et al.  An inexpensive sleep-wake state analyzer for the rat , 1988, Physiology & Behavior.

[2]  E. Jurkowlaniec,et al.  Differential effect of the damage to the lateral hypothalamic area on hippocampal theta rhythm during waking and paradoxical sleep. , 1989, Acta neurobiologiae experimentalis.

[3]  G. Lacoste,et al.  Automatic analysis of the sleep-waking cycle in the rat recorded by miniature telemetry , 1977, Brain Research.

[4]  R. Horner,et al.  On-line detection of sleep-wake states and application to produce intermittent hypoxia only in sleep in rats. , 2001, Journal of applied physiology.

[5]  E. Pérez-Garci,et al.  EEG bands during wakefulness, slow-wave, and paradoxical sleep as a result of principal component analysis in the rat. , 2000, Sleep.

[6]  A. Coenen,et al.  An EEG averaging technique for automated sleep-wake stage identification in the rat , 1984, Physiology & Behavior.

[7]  J. Winson,et al.  A simple sleep stage detector for the rat. , 1976, Electroencephalography and clinical neurophysiology.

[8]  A. Rechtschaffen,et al.  NREM sleep with low-voltage EEG in the rat. , 1987, Sleep.

[9]  R. Huber,et al.  Topography of EEG dynamics after sleep deprivation in mice. , 2000, Journal of neurophysiology.

[10]  G Gandolfo,et al.  Automatic sleep-wake scoring in the rat on microcomputer APPLE II. , 1988, International journal of bio-medical computing.

[11]  T. Penzel,et al.  Computer based sleep recording and analysis. , 2000, Sleep medicine reviews.

[12]  W C Dement,et al.  Real-time automated sleep scoring: validation of a microcomputer-based system for mice. , 1991, Sleep.

[13]  D. Neckelmann,et al.  The reliability and functional validity of visual and semiautomatic sleep/wake scoring in the Møll-Wistar rat. , 1994, Sleep.

[14]  E. Phillipson,et al.  Immediate effects of arousal from sleep on cardiac autonomic outflow in the absence of breathing in dogs. , 1995, Journal of applied physiology.

[15]  C. Robert,et al.  Adult rat vigilance states discrimination by artificial neural networks using a single EEG channel , 1996, Physiology & Behavior.

[16]  H. Heller,et al.  Scoring transitions to REM sleep in rats based on the EEG phenomena of pre-REM sleep: an improved analysis of sleep structure. , 1994, Sleep.

[17]  A Limoge,et al.  Real-time sleep-wake scoring in the rat using a single EEG channel. , 1994, Sleep.

[18]  Chao Li,et al.  An automated pontine-wave detection system. , 2003, Sleep.

[19]  C J Goeller,et al.  A microcomputer-based sleep stage analyzer. , 1989, Computer methods and programs in biomedicine.

[20]  A. Borbély Effects of light on sleep and activity rhythms , 1978, Progress in Neurobiology.

[21]  G. Ruigt,et al.  A large scale, high resolution, automated system for rat sleep staging. II. Validation and application. , 1989, Electroencephalography and clinical neurophysiology.

[22]  P. Achermann,et al.  Regional differences in the dynamics of the cortical EEG in the rat after sleep deprivation , 1999, Clinical Neurophysiology.