Harmonic Current Distribution in Grounding Systems of Cabled Medium Voltage Grids during Single-Pole Ground Fault

The design of every power supply system must guarantee the safety for human life even in the event of a fault. Due to the system change in the electrical power supply, the fault current contains more and more unknown shares of current harmonics. Especially in medium voltage grids, which are operated with resonant grounding, these are determining for the level of the single-pole ground fault current for determination of permissible touch voltages and compliance with the normative requirements of the European standard EN 50522 must therefore be re-evaluated. In its first part, this concept paper presents the frequency dependent principles of earth loops formed by the grounding system. The focus here is on cabled grids and the influence of connected structures of the low voltage grid. The second part deals with the superposition of these loop currents and the resulting earth currents in case of a line to ground fault. The authors address explicitly the frequency dependence of the current distribution and describe the expected behaviour for current harmonics. The proposed approaches result from processing the state of knowledge, research work and the evaluation of several measurements. The aim is to develop an understanding of the influence of the components connected to a grounding system and to derive generally applicable principles. Therefore, the authors present the results of recent measurements in the last part of the handed paper and point out the possibilities and limits of modeling. It is shown that a dedicated treatment of harmonic currents in the case of a single-pole fault is possible with the methods described. This allows these to be neglected in the estimation of touch voltages under specified circumstances, saving costs for the assessment of grounding systems.

[1]  Ernst Schmautzer,et al.  The role of global earthing systems to ensure the reliability of electrical networks , 2016, 2016 51st International Universities Power Engineering Conference (UPEC).

[2]  P. Toman,et al.  Experimental measuring of the touch voltages in large compensated networks , 2012, 2012 Electric Power Quality and Supply Reliability.

[3]  Gaetano Zizzo,et al.  Electrical Safety of Resonant Grounding , 2019, 2019 IEEE/IAS 55th Industrial and Commercial Power Systems Technical Conference (I&CPS).

[4]  L. Fickert,et al.  Earth fault current distribution and proof method of global earthing systems , 2018, 2018 19th International Scientific Conference on Electric Power Engineering (EPE).

[5]  Enrico Pons,et al.  The identification of global earthing systems: A review and comparison of methodologies , 2016, 2016 IEEE 16th International Conference on Environment and Electrical Engineering (EEEIC).

[6]  Peter Schegner,et al.  New method for calculation of the harmonics in the residual earth fault current in isolated and compensated networks , 2016, 2016 Electric Power Quality and Supply Reliability (PQ).

[7]  Jörg Franke,et al.  A novel method to reduce the harmonic currents in the residual earth fault current during a single phase to ground fault in compensated grids , 2019, 2019 IEEE PES Innovative Smart Grid Technologies Europe (ISGT-Europe).

[8]  R. Probst,et al.  An improved algorithm for determination of cable parameters based on frequency-dependent conductor segmentation , 2012, PES T&D 2012.

[9]  Ljubivoje M. Popovic,et al.  Ground Fault Current Distribution When a Ground Fault Occurs in HV Substations Located in an Urban Area , 2014 .

[10]  Massimo Mitolo,et al.  Electrical Safety Analysis in the Presence of Resonant Grounding Neutral , 2019, IEEE Transactions on Industry Applications.

[11]  I. Sarajcev,et al.  Current reduction factor of compensation conductors laid alongside three single-core cables in flat formation , 2003, 2003 IEEE International Symposium on Electromagnetic Compatibility, 2003. EMC '03..

[12]  Matislav Majstrović,et al.  Calculation of earthing and screening effects of compensation conductor laid alongside underground multi-cable power lines , 2004 .

[13]  Ljubivoje M. Popović Reduction of the fault current passing through the grounding system of an HV substation supplied by cable line , 2018 .

[14]  Kun Yu,et al.  A novel full compensation method for the ground fault current of resonant grounded systems , 2021 .

[15]  Peter Schegner,et al.  Model for the calculation of harmonics in the residual earth fault current of medium voltage systems , 2017 .

[16]  Ljubivoje M Popović,et al.  DETERMINATION OF ACTUAL REDUCTION FACTOR OF HV AND MV CABLE LINES PASSING THROUGH URBAN AND SUBURBAN AREAS , 2014 .

[17]  Enrico Pons,et al.  MV ground fault current distribution: An analytical formulation of the reduction factor , 2017, 2017 IEEE International Conference on Environment and Electrical Engineering and 2017 IEEE Industrial and Commercial Power Systems Europe (EEEIC / I&CPS Europe).

[18]  Luigi Martirano,et al.  Identification of Global Grounding Systems: The Global Zone of Influence , 2015, IEEE Transactions on Industry Applications.