Improvement in Arteral Oxygen Control Using Multiple-Model Adaptive Control Procedures

A computer-based proportional-integral (PI) controller has been developed to control arterial oxygen levels in mechanically ventilated animals. Arterial oxygen saturation is monitored using a noninvasive oximeter and control is effected by adjusting the inspired oxygen fraction. The performance of the feedback system is sensitive to the open-loop gain so that the desired transient specifications can be achieved only by empirical adjustments of the PI controller. Because the open-loop gain includes the animal's response, it may vary with time and with the administration of positive end-expiratory pressure. Multiple-model adaptive control procedures were therefore used to desensitize the system to these variable gains. Computer simulations demonstrated the effectiveness of the algorithm over a wide variation of plant parameters. A comparison to a fixed, well-tuned proportional-integral controller showed an improvement in the regulatory response to a step disturbance. Animal experiments confirmed the feasibility of using multiple-model adaptive control to regulate arterial oxygen saturation.

[1]  E. I. Jury,et al.  Theory and application of the z-transform method , 1965 .

[2]  Howard Kaufman,et al.  Adaptive Control of Multiple Drug Infusions , 1983 .

[3]  Mark Yelderman,et al.  Evaluation of pulse oximetry. , 1983, Anesthesiology.

[4]  J. Severinghaus Simple, accurate equations for human blood O2 dissociation computations. , 1979, Journal of applied physiology: respiratory, environmental and exercise physiology.

[5]  Howard Kaufman,et al.  Model reference adaptive control of drug infusion rate , 1984, Autom..

[6]  Charles M. Close,et al.  Modeling and Analysis of Dynamic Systems , 1978 .

[7]  W. G. He,et al.  Multiple Model Adaptive Control Procedure for Blood Pressure Control , 1986, IEEE Transactions on Biomedical Engineering.

[8]  Karl Johan Åström,et al.  Computer-Controlled Systems: Theory and Design , 1984 .

[9]  M Yelderman,et al.  Evaluation of pulse oximetry. , 1983, Anesthesiology.

[10]  N. Saunders,et al.  Ear oximetry: accuracy and practicability in the assessment of arterial oxygenation. , 1976, The American review of respiratory disease.

[11]  C Yoshimoto,et al.  An optimally controlled respirator. , 1971, IEEE transactions on bio-medical engineering.

[12]  Davio R. Hebrank Noninvasive Transcutaneous Oxygen Monitoring, A Review , 1981 .

[13]  A. Guyton,et al.  Textbook of Medical Physiology , 1961 .

[14]  Pradeep B. Deshpande,et al.  Elements of computer process control with advanced control applications , 1981 .

[15]  L. R. Gieszl,et al.  Hint for squint: a computer reliant diagnostic aid for strabismus , 1983 .

[16]  Julius T. Tou,et al.  Digital and sampled-data control systems , 1963 .