Improved synthetic aperture focusing technique with applications in high-frequency ultrasound imaging

Synthetic aperture focusing using a virtual source was used previously to increase the penetration and to extend the depth of focus in high-frequency ultrasonic imaging. However, the performance of synthetic aperture focusing is limited by its high sidelobes. In this paper, an adaptive weighting technique based on a focusing-quality index is introduced to suppress the sidelobes. The focusing-quality index is derived from the spatial spectrum of the scan-line data along the mechanical scan direction (i.e., the synthetic aperture direction) after focusing delays relative to the virtual source have been applied. The proposed technique is of particular value in high-frequency ultrasound in which dynamic focusing using array transducers is not yet possible. Experimental ultrasound data from a 50-MHz imaging system with a single-crystal transducer (f-number=2) are used to demonstrate the efficacy of the proposed technique on both wire targets and speckle-generating objects. An in vivo experiment also is performed on a mouse to further demonstrate the effectiveness. Both 50-MHz fundamental imaging and 50-MHz tissue harmonic imaging are tested. The results clearly demonstrate the effectiveness in sidelobe reduction and background-noise suppression for both imaging modes. The principles, experimental results, and implementation issues of the new technique are described in this paper.

[1]  F. Foster,et al.  A 100-200 MHz ultrasound biomicroscope , 2000, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[2]  Pai-Chi Li,et al.  A new adaptive imaging technique using generalized coherence factor , 2002, 2002 IEEE Ultrasonics Symposium, 2002. Proceedings..

[3]  Pai-Chi Li,et al.  Adaptive imaging using the generalized coherence factor. , 2003, IEEE transactions on ultrasonics, ferroelectrics, and frequency control.

[4]  F Patat,et al.  High-resolution real-time ultrasonic scanner. , 1992, Ultrasound in medicine & biology.

[5]  K. W. Rigby,et al.  Efficient parallel adaptive aberration correction , 1998, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[6]  W.D. O'Brien,et al.  Synthetic aperture techniques with a virtual source element , 1998, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[7]  T. Christopher Finite amplitude distortion-based inhomogeneous pulse echo ultrasonic imaging , 1997, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[8]  Pai-Chi Li,et al.  Harmonic leakage and image quality degradation in tissue harmonic imaging. , 2001, IEEE transactions on ultrasonics, ferroelectrics, and frequency control.

[9]  Katherine W. Ferrara,et al.  A hand-held, high frequency ultrasound scanner , 2001, 2001 IEEE Ultrasonics Symposium. Proceedings. An International Symposium (Cat. No.01CH37263).

[10]  H. Ermert,et al.  A 100-MHz ultrasound imaging system for dermatologic and ophthalmologic diagnostics , 1996, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[12]  M. Bae,et al.  A study of synthetic-aperture imaging with virtual source elements in B-mode ultrasound imaging systems. , 2000, IEEE transactions on ultrasonics, ferroelectrics, and frequency control.

[13]  M. O'Donnell,et al.  Synthetic aperture imaging for small scale systems , 1995, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[14]  M. O'Donnell,et al.  Coherence factor of speckle from a multi-row probe , 1999, 1999 IEEE Ultrasonics Symposium. Proceedings. International Symposium (Cat. No.99CH37027).

[15]  K. K. Shung,et al.  Development of sector scanning ultrasonic backscatter microscope , 2000, 2000 IEEE Ultrasonics Symposium. Proceedings. An International Symposium (Cat. No.00CH37121).

[16]  C. Chin,et al.  Pulse inversion Doppler: a new method for detecting nonlinear echoes from microbubble contrast agents , 1999, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[17]  E. Cherin,et al.  Comparison of nonlinear and linear imaging techniques at high frequency , 2000, 2000 IEEE Ultrasonics Symposium. Proceedings. An International Symposium (Cat. No.00CH37121).

[18]  F. S. Foster,et al.  Beyond 30 MHz [applications of high-frequency ultrasound imaging] , 1996 .

[19]  D. A. Christopher,et al.  Advances in ultrasound biomicroscopy. , 2000, Ultrasound in medicine & biology.

[20]  M. O'Donnell Efficient parallel receive beam forming for phased array imaging using phase rotation (medical US application) , 1990, IEEE Symposium on Ultrasonics.

[21]  E. Feleppa,et al.  Three-dimensional biometric images of ocular structures using very-high-frequency ultrasound , 1999, 1999 IEEE Ultrasonics Symposium. Proceedings. International Symposium (Cat. No.99CH37027).

[22]  Helmut Ermert,et al.  In vivo imaging of the skin in the 100 MHz region using the synthetic aperture concept , 1995, 1995 IEEE Ultrasonics Symposium. Proceedings. An International Symposium.