Quality control procedures for dynamic treatment delivery techniques involving couch motion.

In this study, the authors introduce and demonstrate quality control procedures for evaluating the geometric and dosimetric fidelity of dynamic treatment delivery techniques involving treatment couch motion synchronous with gantry and multileaf collimator (MLC). Tests were designed to evaluate positional accuracy, velocity constancy and accuracy for dynamic couch motion under a realistic weight load. A test evaluating the geometric accuracy of the system in delivering treatments over complex dynamic trajectories was also devised. Custom XML scripts that control the Varian TrueBeam™ STx (Serial #3) axes in Developer Mode were written to implement the delivery sequences for the tests. Delivered dose patterns were captured with radiographic film or the electronic portal imaging device. The couch translational accuracy in dynamic treatment mode was 0.01 cm. Rotational accuracy was within 0.3°, with 0.04 cm displacement of the rotational axis. Dose intensity profiles capturing the velocity constancy and accuracy for translations and rotation exhibited standard deviation and maximum deviations below 3%. For complex delivery involving MLC and couch motions, the overall translational accuracy for reproducing programmed patterns was within 0.06 cm. The authors conclude that in Developer Mode, TrueBeam™ is capable of delivering dynamic treatment delivery techniques involving couch motion with good geometric and dosimetric fidelity.

[1]  James L Bedford,et al.  Helical volumetric modulated arc therapy for treatment of craniospinal axis. , 2012, International journal of radiation oncology, biology, physics.

[2]  Margie Hunt,et al.  Choreographing couch and collimator in volumetric modulated arc therapy. , 2011, International journal of radiation oncology, biology, physics.

[3]  J. Bedford,et al.  Commissioning of volumetric modulated arc therapy (VMAT). , 2009, International journal of radiation oncology, biology, physics.

[4]  Lei Xing,et al.  Prone Partial Breast Coronal Arc Irradiation: Combining Intensity Modulated Delivery With Dynamic Motion of the Couch , 2012 .

[5]  Maria T. Vlachaki,et al.  Simultaneous couch and gantry dynamic arc rotation (CG‐Darc) in the treatment of breast cancer with accelerated partial breast irradiation (APBI): a feasibility study , 2013, Journal of applied clinical medical physics.

[6]  K M Ayyangar,et al.  Commissioning and quality assurance for MLC-based IMRT. , 2001, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[7]  David Sjostrom,et al.  Implementing RapidArc into clinical routine: a comprehensive program from machine QA to TPS validation and patient QA. , 2011, Medical physics.

[8]  Lei Xing,et al.  Trajectory modulated prone breast irradiation: a LINAC-based technique combining intensity modulated delivery and motion of the couch. , 2013, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[9]  Piotr Zygmanski,et al.  An oscillating sweeping gap test for VMAT quality assurance , 2010, Physics in medicine and biology.

[10]  M Saiful Huq,et al.  A dosimetric comparison of various multileaf collimators. , 2002, Physics in medicine and biology.

[11]  Di Yan,et al.  Continuous arc rotation of the couch therapy for the delivery of accelerated partial breast irradiation: a treatment planning analysis. , 2011, International journal of radiation oncology, biology, physics.

[12]  Mauro Iori,et al.  Acceptance tests and quality control (QC) procedures for the clinical implementation of intensity modulated radiotherapy (IMRT) using inverse planning and the sliding window technique: experience from five radiotherapy departments. , 2002, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[13]  C. Ling,et al.  Commissioning and quality assurance of RapidArc radiotherapy delivery system. , 2008, International journal of radiation oncology, biology, physics.

[14]  Ke Sheng,et al.  4π non-coplanar liver SBRT: a novel delivery technique. , 2013, International Journal of Radiation Oncology, Biology, Physics.

[15]  S. Morrill,et al.  MLC quality assurance techniques for IMRT applications. , 2003, Medical physics.

[16]  Karl Otto,et al.  Volumetric modulated arc therapy: IMRT in a single gantry arc. , 2007, Medical physics.