Numerical Simulation of Single-Point Mount PZT-Interface for Admittance-Based Anchor Force Monitoring

This study investigates the dynamic characteristics of a smart PZT interface mounted on a prestressed anchorage to verify the numerical feasibility of the admittance-based anchor force monitoring technique. Firstly, the admittance-based anchor force monitoring technique through a single-mount PZT interface is outlined. The admittance response of the PZT interface-anchorage system is theoretically derived to show the proof-of-concept of the technique for anchor force monitoring. Secondly, a finite element model corresponding to a well-established experimental model in the literature is constructed. The effect of anchor force is equivalently treated by the contact stiffness and damping parameters at the bottom surface of the anchorage. Thirdly, the admittance and the impedance responses are numerically analyzed and compared with the experimental data to evaluate the accuracy of the numerical modelling technique. Fourthly, the local dynamics of the PZT interface are analyzed by modal analysis to determine vibration modes that are sensitive to the change in the contact stiffness (i.e., representing the anchor force). Finally, the admittance responses corresponding to the sensitive vibration modes are numerically analyzed under the change in the contact stiffness. The frequency shift and the admittance change are quantified by statistical damage indices to verify the numerical feasibility of the anchor force monitoring technique via the smart PZT interface. The study is expected to provide a reference numerical model for the design of the single-point mount PZT interface.

[1]  Thi Tuong Vy Phan,et al.  A Low-Cost Prestress Monitoring Method for Post-Tensioned RC Beam Using Piezoelectric-Based Smart Strand , 2021, Buildings.

[2]  T. Huynh,et al.  Anchor Force Monitoring Using Impedance Technique with Single-Point Mount Lead-Zirconate-Titanate Interface: A Feasibility Study , 2021, Buildings.

[3]  Thanh-Canh Huynh,et al.  Understanding Impedance Response Characteristics of a Piezoelectric-Based Smart Interface Subjected to Functional Degradations , 2021, Complex..

[4]  Duc-Duy Ho,et al.  Deep learning-based functional assessment of piezoelectric-based smart interface under various degradations , 2021 .

[5]  T. Chakraborty,et al.  Viability of electro-mechanical impedance technique for monitoring damage in rocks under cyclic loading , 2021, Acta Geotechnica.

[6]  Thanh-Canh Huynh,et al.  Structural parameter identification of a bolted connection embedded with a piezoelectric interface , 2020 .

[7]  Xia Yang,et al.  Monitoring of Interfacial Debonding of Concrete Filled Pultrusion-GFRP Tubular Column Based on Piezoelectric Smart Aggregate and Wavelet Analysis , 2020, Sensors.

[8]  Jeong‐Tae Kim,et al.  Damage‐sensitive impedance sensor placement on multi‐strand anchorage based on local stress variation analysis , 2020, Structural Control and Health Monitoring.

[9]  Jeong-Tae Kim,et al.  Sensitivity of Piezoelectric-Based Smart Interfaces to Structural Damage in Bolted Connections , 2019, Sensors.

[10]  Ting-Hua Yi,et al.  PZT based smart corrosion coupon using electromechanical impedance , 2019, Mechanical Systems and Signal Processing.

[11]  Jeong-Tae Kim,et al.  Sensing Region Characteristics of Smart Piezoelectric Interface for Damage Monitoring in Plate-Like Structures , 2019, Sensors.

[12]  Jeong-Tae Kim,et al.  Local Strand-Breakage Detection in Multi-Strand Anchorage System Using an Impedance-Based Stress Monitoring Method—Feasibility Study , 2019, Sensors.

[13]  Jeong-Tae Kim,et al.  Tension Force Estimation in Axially Loaded Members Using Wearable Piezoelectric Interface Technique , 2018, Sensors.

[14]  Michael F. Zaeh Damping , 2019, CIRP Encyclopedia of Production Engineering.

[15]  Jeong-Tae Kim,et al.  Preload Monitoring in Bolted Connection Using Piezoelectric-Based Smart Interface , 2018, Sensors.

[16]  Jeong-Tae Kim,et al.  RBFN‐based temperature compensation method for impedance monitoring in prestressed tendon anchorage , 2018 .

[17]  Jongdae Baek,et al.  A Review of the Piezoelectric Electromechanical Impedance Based Structural Health Monitoring Technique for Engineering Structures , 2018, Sensors.

[18]  Ricardo Perera,et al.  Active Wireless System for Structural Health Monitoring Applications , 2017, Sensors.

[19]  P. Woias,et al.  Design, Characterization and Sensitivity Analysis of a Piezoelectric Ceramic/Metal Composite Transducer , 2017, Micromachines.

[20]  Thanh-Canh Huynh,et al.  Feasibility Verification of Mountable PZT-Interface for Impedance Monitoring in Tendon-Anchorage , 2015 .

[21]  Jeong-Tae Kim,et al.  Impedance-Based Cable Force Monitoring in Tendon-Anchorage Using Portable PZT-Interface Technique , 2014 .

[22]  Michael A. Sutton,et al.  Predictive modeling of electromechanical impedance spectroscopy for composite materials , 2012 .

[23]  Jeong-Tae Kim,et al.  Smart PZT-interface for wireless impedance-based prestress-loss monitoring in tendon-anchorage connection , 2012 .

[24]  Khac-Duy Nguyen,et al.  Wireless Impedance Sensor Node and Interface Washer for Damage Monitoring in Structural Connections , 2012 .

[25]  Chung Bang Yun,et al.  Impedance-based structural health monitoring using neural networks for autonomous frequency range selection , 2010 .

[26]  Jerome P. Lynch,et al.  Autonomous smart sensor nodes for global and local damage detection of prestressed concrete bridges based on accelerations and impedance measurements , 2010 .

[27]  Dong-Soo Hong,et al.  Hybrid health monitoring of prestressed concrete girder bridges by sequential vibration-impedance approaches , 2010 .

[28]  Seunghee Park,et al.  Wireless impedance sensor nodes for functions of structural damage identification and sensor self-diagnosis , 2009 .

[29]  Gangbing Song,et al.  Health monitoring of reinforced concrete shear walls using smart aggregates , 2009 .

[30]  Gangbing Song,et al.  Smart aggregates: multi-functional sensors for concrete structures—a tutorial and a review , 2008 .

[31]  Hui Liu,et al.  Monitoring damage propagation using PZT impedance transducers , 2008, SPIE Smart Structures and Materials + Nondestructive Evaluation and Health Monitoring.

[32]  Yaowen Yang,et al.  Sensitivity of PZT Impedance Sensors for Damage Detection of Concrete Structures , 2008, Sensors.

[33]  Daniel J. Inman,et al.  Impedance‐Based Structural Health Monitoring , 2005 .

[34]  Yozo Fujino,et al.  Quantitative health monitoring of bolted joints using a piezoceramic actuator-sensor , 2004 .

[35]  Gui-Rong Liu,et al.  A Modified Electro-Mechanical Impedance Model of Piezoelectric Actuator-Sensors for Debonding Detection of Composite Patches , 2002 .

[36]  Victor Giurgiutiu,et al.  Electro-Mechanical Impedance Method for Crack Detection in Thin Plates , 2001 .