Motion correction for phase-resolved dynamic optical coherence tomography imaging of rodent cerebral cortex

Cardiac and respiratory motions in animals are the primary source of image quality degradation in dynamic imaging studies, especially when using phase-resolved imaging modalities such as spectral-domain optical coherence tomography (SD-OCT), whose phase signal is very sensitive to movements of the sample. This study demonstrates a method with which to compensate for motion artifacts in dynamic SD-OCT imaging of the rodent cerebral cortex. We observed that respiratory and cardiac motions mainly caused, respectively, bulk image shifts (BISs) and global phase fluctuations (GPFs). A cross-correlation maximization-based shift correction algorithm was effective in suppressing BISs, while GPFs were significantly reduced by removing axial and lateral global phase variations. In addition, a non-origin-centered GPF correction algorithm was examined. Several combinations of these algorithms were tested to find an optimized approach that improved image stability from 0.5 to 0.8 in terms of the cross-correlation over 4 s of dynamic imaging, and reduced phase noise by two orders of magnitude in ~8% voxels.

[1]  Oliver Speck,et al.  Magnetic resonance imaging of freely moving objects: prospective real-time motion correction using an external optical motion tracking system , 2006, NeuroImage.

[2]  M. Pierce,et al.  Simultaneous intensity, birefringence, and flow measurements with high-speed fiber-based optical coherence tomography. , 2002, Optics letters.

[3]  Tayyaba Hasan,et al.  Diffusive and directional intracellular dynamics measured by field-based dynamic light scattering , 2010, Optics express.

[4]  David A Boas,et al.  Rapid volumetric angiography of cortical microvasculature with optical coherence tomography. , 2010, Optics letters.

[5]  B. E. Bouma,et al.  Compensation of motion artifacts in catheter-based optical frequency domain imaging , 2010, Optics express.

[6]  Harald Sattmann,et al.  In vivo investigation of human cone photoreceptors with SLO/OCT in combination with 3D motion correction on a cellular level. , 2010, Optics express.

[7]  Taner Akkin,et al.  Depth-resolved measurement of transient structural changes during action potential propagation. , 2007, Biophysical journal.

[8]  Benoit M. Dawant,et al.  Correction of motion artifact in cardiac optical mapping using image registration , 2005, IEEE Transactions on Biomedical Engineering.

[9]  Sylvain Gioux,et al.  Motion-gated acquisition for in vivo optical imaging. , 2009, Journal of biomedical optics.

[10]  A. Fercher,et al.  Performance of fourier domain vs. time domain optical coherence tomography. , 2003, Optics express.

[11]  P. Georges,et al.  Motion artifact suppression in full-field optical coherence tomography. , 2010, Applied optics.

[12]  J. Izatt,et al.  High resolution imaging of in vivo cardiac dynamics using color Doppler optical coherence tomography. , 1997, Optics express.

[13]  Roger Fulton,et al.  An Event-Driven Motion Correction Method for Neurological PET Studies of Awake Laboratory Animals , 2008, Molecular Imaging and Biology.

[14]  A Z Kyme,et al.  Real-time 3D motion tracking for small animal brain PET , 2008, Physics in medicine and biology.

[15]  Anna Devor,et al.  Optical coherence tomography (OCT) reveals depth-resolved dynamics during functional brain activation , 2009, Journal of Neuroscience Methods.

[16]  J. Fujimoto,et al.  In vivo endoscopic optical biopsy with optical coherence tomography. , 1997, Science.

[17]  Margaret E. Daube-Witherspoon,et al.  A head motion measurement system suitable for emission computed tomography , 1997, IEEE Transactions on Medical Imaging.

[18]  O. Speck,et al.  Prospective Real-Time Slice-by-Slice Motion Correction for fMRI in Freely Moving Subjects , 2006, Magnetic Resonance Materials in Physics, Biology and Medicine.

[19]  B. Bouma,et al.  Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography. , 2003, Optics letters.