Towards time-of-flight PET with a semiconductor detector

The feasibility of using Cerenkov light, generated by energetic electrons following 511 keV photon interactions in the semiconductor TlBr, to obtain fast timing information for positron emission tomography (PET) was evaluated. Due to its high refractive index, TlBr is a relatively good Cerenkov radiator and with its wide bandgap, has good optical transparency across most of the visible spectrum. Coupling an SiPM photodetector to a slab of TlBr (TlBr-SiPM) yielded a coincidence timing resolution of 620 ps FWHM between the TlBr-SiPM detector and a LFS reference detector. This value improved to 430 ps FWHM by applying a high pulse amplitude cut based on the TlBr-SiPM and reference detector signal amplitudes. These results are the best ever achieved with a semiconductor PET detector and already approach the performance required for time-of-flight. As TlBr has higher stopping power and better energy resolution than the conventional scintillation detectors currently used in PET scanners, a hybrid TlBr-SiPM detector with fast timing capability becomes an interesting option for further development.

[1]  G. Bizarri,et al.  Bright and ultra-fast scintillation from a semiconductor? , 2016, Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment.

[2]  Alberto Gola,et al.  Bismuth germanate coupled to near ultraviolet silicon photomultipliers for time-of-flight PET , 2016, Physics in medicine and biology.

[3]  Simon R. Cherry,et al.  In vivo Cerenkov luminescence imaging: a new tool for molecular imaging , 2011, Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences.

[4]  Simon R. Cherry,et al.  chapter 7 – Radiation Detectors , 2012 .

[5]  Goro Sato,et al.  CdTe and CdZnTe detectors for timing measurements , 2001 .

[6]  A. Dell'Acqua,et al.  Geant4 - A simulation toolkit , 2003 .

[7]  M. Kolstein,et al.  Energy and coincidence time resolution measurements of CdTe detectors for PET. , 2013, Journal of instrumentation : an IOP and SISSA journal.

[8]  Suleman Surti,et al.  Update on Time-of-Flight PET Imaging , 2015, The Journal of Nuclear Medicine.

[9]  M. Moszynski,et al.  MPPC arrays in PET detectors with LSO and BGO scintillators , 2011, 2011 IEEE Nuclear Science Symposium Conference Record.

[10]  M. A. Cortés-Giraldo,et al.  Progress in Geant4 Electromagnetic Physics Modelling and Validation , 2015 .

[11]  Kanai S. Shah,et al.  Purification, crystal growth and detector performance of TlBr , 2008, Optical Engineering + Applications.

[12]  F. Beekman,et al.  LaBr3:Ce and SiPMs for time-of-flight PET: achieving 100 ps coincidence resolving time , 2010, Physics in medicine and biology.

[13]  I. Somlai-Schweiger,et al.  CHERENCUBE: concept definition and implementation challenges of a Cherenkov-based detector block for PET. , 2015, Medical physics.

[14]  J. C. Zhang,et al.  Hybrid Pixel-Waveform (HPWF) Enabled CdTe Detectors for Small Animal Gamma-Ray Imaging Applications , 2017, IEEE Transactions on Radiation and Plasma Medical Sciences.

[15]  Suleman Surti,et al.  Parallax error in long-axial field-of-view PET scanners—a simulation study , 2016, Physics in medicine and biology.

[16]  Thomas K Lewellen,et al.  The challenge of detector designs for PET. , 2010, AJR. American journal of roentgenology.

[17]  Irving H. Malitson,et al.  Refraction and Dispersion of Thallium Bromide Iodide , 1956 .

[19]  S. Sinha,et al.  CdTe Strip Detector Characterization for High Resolution Small Animal PET , 2008, IEEE Transactions on Nuclear Science.

[20]  F. Olschner,et al.  Developing Larger TlBr Detectors—Detector Performance , 2009, IEEE Transactions on Nuclear Science.

[21]  Shiva Abbaszadeh,et al.  New-generation small animal positron emission tomography system for molecular imaging , 2017, Journal of medical imaging.