Event-related functional MR imaging of visual cortex stimulation at high temporal resolution using a standard 1.5 T imager.

The authors report the technical feasibility of measuring event-related changes in blood oxygenation for studying brain function in humans at high temporal resolution. Measurements were performed on a conventional whole-body 1.5 T clinical scanner with a nonactive-shielded standard gradient system of 1 ms rise time for a maximum gradient strength of 10 mT/m. The radiofrequency (RF) transmitting and receiving MR unit consists of a commercially available circular polarized head coil. Magnet shimming with all first-order coils was performed to the volunteer's head resulting in a magnetic field homogeneity of about 0.1-0.2 ppm. The measuring sequence used was a modified 3D, first-order flow rephased, FLASH sequence with reduced bandwidth = 40 Hz/pixel, TR = 80 ms, TE = 56 ms, flip angle = 40-50 degrees, matrix = 64 x 128, field-of-view = 200-250 mm2, slice thickness = 4 mm, NEX = 1,128 partitions, and a total single scan time of about 10 min. In this sequence the 3D gradient table was removed and the 3D partition-loop acts as a time-loop for sequential measurement of 128 or 32 consecutive images at the same slice position. This means that event-related functional MRI could be performed with an interscan delay of 80 ms for a series of 128 sequential images or with an interscan delay of 320 ms for a simultaneous measurement of four slices with a series of 32 sequential images for each slice. We used a TTL signal given by the gradient board at the beginning of every line-loop in the measuring sequence and a self-made "TTL-Divider-Box" for the event triggering. This box was used to count and scale down the TTL signals by a factor of 128 and to trigger after every 128th TTL signal a single white flash-light, which was seen by the volunteer in the dark room of the scanner with a period of 10.24 s. As a consequence, the resulting event-related scan data coincide at each line of the series of 128 sequential images, which were repeated in 128 x 80 ms or 32 x 320 ms for the single- or four-slice experiment, respectively. Visual cortex response magnitude measured was about 5-7% with an approximate Gaussian shape and a rise time from stimulus onset to maximum of about 3-4 s, and a fall time to the baseline of about 5-6 s after end of stimulus. The reported data demonstrate the feasibility of functional MRI studies at high temporal resolution (up to 80 ms) using conventional MR equipment and measuring sequence.

[1]  L R Schad,et al.  Functional magnetic resonance imaging at 1.5 T: activation pattern in schizophrenic patients receiving neuroleptic medication. , 1994, Magnetic resonance imaging.

[2]  J C Gore,et al.  Functional brain imaging at 1.5 T using conventional gradient echo MR imaging techniques. , 1993, Magnetic resonance imaging.

[3]  R. S. Hinks,et al.  Time course EPI of human brain function during task activation , 1992, Magnetic resonance in medicine.

[4]  J. Frahm,et al.  Functional MRI of human brain activation at high spatial resolution , 1993, Magnetic resonance in medicine.

[5]  R. Turner,et al.  Functional mapping of the human visual cortex at 4 and 1.5 tesla using deoxygenation contrast EPI , 1993, Magnetic resonance in medicine.

[6]  P. Mansfield Multi-planar image formation using NMR spin echoes , 1977 .

[7]  S. Ogawa,et al.  Oxygenation‐sensitive contrast in magnetic resonance image of rodent brain at high magnetic fields , 1990, Magnetic resonance in medicine.

[8]  R. Turner,et al.  Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation. , 1992, Proceedings of the National Academy of Sciences of the United States of America.

[9]  L R Schad,et al.  Motor cortex stimulation measured by magnetic resonance imaging on a standard 1.5 T clinical scanner. , 1993, Magnetic resonance imaging.

[10]  Ravi S. Menon,et al.  Intrinsic signal changes accompanying sensory stimulation: functional brain mapping with magnetic resonance imaging. , 1992, Proceedings of the National Academy of Sciences of the United States of America.

[11]  L R Schad,et al.  Functional 2D and 3D magnetic resonance imaging of motor cortex stimulation at high spatial resolution using standard 1.5 T imager. , 1994, Magnetic resonance imaging.