Simulating Arbitrary Electrode Reversals in Standard 12-Lead ECG

Electrode reversal errors in standard 12-lead electrocardiograms (ECG) can produce significant ECG changes and, in turn, misleading diagnoses. Their detection is important but mostly limited to the design of criteria using ECG databases with simulated reversals, without Wilson’s central terminal (WCT) potential change. This is, to the best of our knowledge, the first study that presents an algebraic transformation for simulation of all possible ECG cable reversals, including those with displaced WCT, where most of the leads appear with distorted morphology. The simulation model of ECG electrode swaps and the resultant WCT potential change is derived in the standard 12-lead ECG setup. The transformation formulas are theoretically compared to known limb lead reversals and experimentally proven for unknown limb–chest electrode swaps using a 12-lead ECG database from 25 healthy volunteers (recordings without electrode swaps and with 5 unicolor pairs swaps, including red (right arm—C1), yellow (left arm—C2), green (left leg (LL) —C3), black (right leg (RL)—C5), all unicolor pairs). Two applications of the transformation are shown to be feasible: ‘Forward’ (simulation of reordered leads from correct leads) and ‘Inverse’ (reconstruction of correct leads from an ECG recorded with known electrode reversals). Deficiencies are found only when the ground RL electrode is swapped as this case requires guessing the unknown RL electrode potential. We suggest assuming that potential to be equal to that of the LL electrode. The ‘Forward’ transformation is important for comprehensive training platforms of humans and machines to reliably recognize simulated electrode swaps using the available resources of correctly recorded ECG databases. The ‘Inverse’ transformation can save time and costs for repeated ECG recordings by reconstructing the correct lead set if a lead swap is detected after the end of the recording. In cases when the electrode reversal is unknown but a prior correct ECG recording of the same patient is available, the ‘Inverse’ transformation is tested to detect the exact swapping of the electrodes with an accuracy of (96% to 100%).

[1]  J A Kors,et al.  Accurate automatic detection of electrode interchange in the electrocardiogram. , 2001, The American journal of cardiology.

[2]  M. Hensey,et al.  Accuracy in precordial ECG lead placement: Improving performance through a peer-led educational intervention. , 2017, Journal of electrocardiology.

[3]  Maneesha V. Ramesh,et al.  QRS axis based classification of electrode interchange in wearable ECG devices , 2015, EAI Endorsed Trans. Future Intell. Educ. Environ..

[4]  Irena Jekova,et al.  Detection of Unicolor ECG Electrode Reversals in Standard 12-Lead ECG , 2018, 2018 Computing in Cardiology Conference (CinC).

[5]  Richard Lynch,et al.  ECG lead misplacement: A brief review of limb lead misplacement , 2014 .

[6]  Saeed Babaeizadeh,et al.  Automatic detection of ECG lead-wire interchange for conventional and Mason-Likar lead systems , 2014, Computing in Cardiology 2014.

[7]  E. W. Hancock,et al.  Recommendations for the standardization and interpretation of the electrocardiogram. Part I: The electrocardiogram and its technology. A scientific statement from the American Heart Association Electrocardiography and Arrhythmias Committee, Council on Clinical Cardiology; the American College of Car , 2007, Heart rhythm.

[8]  Monish S Raut,et al.  Know the errors in ECG recording , 2015 .

[9]  Adrian Baranchuk,et al.  Common ECG Lead Placement Errors. Part II: Precordial Misplacements , 2014 .

[10]  Christian Müller,et al.  Inter-lead correlation analysis for automated detection of cable reversals in 12/16-lead ECG , 2016, Comput. Methods Programs Biomed..

[11]  L. Littmann,et al.  The electrocardiogram of chest and limb lead reversal. , 2014, The American journal of medicine.

[12]  I. Hoffman,et al.  A flatline electrocardiogram in lead II is a marker for right arm/right leg electrode switch. , 2007, Journal of electrocardiology.

[13]  K. C. Ho,et al.  Use of the sinus P wave in diagnosing electrocardiographic limb lead misplacement not involving the right leg (ground) lead. , 2001, Journal of electrocardiology.

[14]  Saeed Babaeizadeh,et al.  Automatic detection of ECG cable interchange by analyzing both morphology and interlead relations. , 2014, Journal of electrocardiology.

[15]  A. Rudiger,et al.  The frequency of electrocardiographic errors due to electrode cable switches: a before and after study. , 2010, Journal of electrocardiology.

[16]  Snehal Kothari,et al.  Limb Lead Interchange in Thorough QT/QTc Studies , 2011, Journal of clinical pharmacology.

[17]  Adrian Baranchuk,et al.  Electrocardiography pitfalls and artifacts: the 10 commandments. , 2009, Critical care nurse.

[18]  V. Figueredo,et al.  Wandering acute myocardial infarction. , 2014, The American journal of medicine.

[19]  Reginald T Ho,et al.  Simple Diagnosis of Limb‐Lead Reversals by Predictable Changes in QRS Axis , 2006, Pacing and clinical electrophysiology : PACE.

[20]  D. Francis,et al.  Accuracy in ECG lead placement among technicians, nurses, general physicians and cardiologists , 2007, International journal of clinical practice.

[21]  C. Cooper,et al.  Enhanced detection of electrode placement/connection errors , 2008, 2008 Computers in Cardiology.

[22]  Saeed Babaeizadeh,et al.  Detecting ECG limb lead-wire interchanges involving the right leg lead-wire , 2017, 2017 Computing in Cardiology (CinC).

[23]  Adrian Baranchuk,et al.  Common ECG Lead Placement Errors. Part I: Limb Lead Reversals , 2014 .

[24]  Paolo Bifulco,et al.  On the “Zero of Potential of the Electric Field Produced by the Heart Beat”. A Machine Capable of Estimating this Underlying Persistent Error in Electrocardiography , 2016 .

[25]  Daniel Guldenring,et al.  A simulation tool for visualizing and studying the effects of electrode misplacement on the 12-lead electrocardiogram. , 2011, Journal of electrocardiology.

[26]  I. Jekova,et al.  Perspectives of human verification via binary QRS template matching of single-lead and 12-lead electrocardiogram , 2018, PloS one.

[27]  Marek Malik,et al.  Incorrect electrode cable connection during electrocardiographic recording. , 2007, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[28]  G. Balázs,et al.  Electrode reversal detection in ECG remote monitoring , 2005 .

[29]  A. Mattu,et al.  Prominent R wave in lead V1: electrocardiographic differential diagnosis. , 2001, The American journal of emergency medicine.

[30]  Xiaopeng Zhao,et al.  Automatic detection of ECG electrode misplacement: a tale of two algorithms , 2012, Physiological measurement.

[31]  H. Mond,et al.  Twisted Leads: The Footprints of Malpositioned Electrocardiographic Leads. , 2016, Heart, lung & circulation.

[32]  D. Benditt,et al.  ECG electrode reversals: An opportunity to learn from mistakes , 2018, Journal of cardiovascular electrophysiology.

[33]  E. W. Hancock,et al.  AHA/ACCF/HRS recommendations for the standardization and interpretation of the electrocardiogram: part III: intraventricular conduction disturbances: a scientific statement from the American Heart Association Electrocardiography and Arrhythmias Committee, Council on Clinical Cardiology; the American , 2009, Journal of the American College of Cardiology.

[34]  J. García-Niebla,et al.  An unusual case of electrode misplacement: left arm and V(2) electrode reversal. , 2008, Journal of electrocardiology.

[35]  O. Pahlm,et al.  Detection of frequently overlooked electrocardiographic lead reversals using artificial neural networks. , 1996, The American journal of cardiology.

[36]  O Pahlm,et al.  Recognition of electrocardiographic electrode misplacements involving the ground (right leg) electrode. , 1993, The American journal of cardiology.

[37]  Ferenc Follath,et al.  Electrocardiographic artifacts due to electrode misplacement and their frequency in different clinical settings. , 2007, The American journal of emergency medicine.

[38]  K. Islam,et al.  Lead-Reversal ECG Simulating Myocardial Infarction – A Case Report and Literature Review , 2017 .

[39]  E. W. Hancock,et al.  Recommendations for the standardization and interpretation of the electrocardiogram: part I: the electrocardiogram and its technology a scientific statement from the American Heart Association Electrocardiography and Arrhythmias Committee, Council on Clinical Cardiology; the American College of Card , 2007, Journal of the American College of Cardiology.

[40]  Gaetano D. Gargiulo,et al.  True Unipolar ECG Machine for Wilson Central Terminal Measurements , 2015, BioMed research international.

[41]  Fabio Badilini,et al.  Comparison of automated interval measurements by widely used algorithms in digital electrocardiographs , 2018, American heart journal.

[42]  D. Mortara,et al.  The development and validation of an early warning system to prevent the acquisition of 12-lead resting ECGs with interchanged electrode positions. , 2014, Journal of electrocardiology.

[43]  Sari U. M. Vanninen,et al.  Electrocardiogram Acquisition Errors or Myocardial Infarct , 2011, Case reports in cardiology.

[44]  J A Milliken,et al.  Recognition of electrocardiographic left arm/left leg lead reversal. , 1997, The American journal of cardiology.

[45]  D Guldenring,et al.  The effects of electrode misplacement on clinicians' interpretation of the standard 12-lead electrocardiogram. , 2012, European journal of internal medicine.