Rapid protein identification using monolithic enzymatic microreactor and LC‐ESI‐MS/MS

A monolithic enzymatic microreactor was prepared in a fused‐silica capillary by in situ polymerization of acrylamide, glycidyl methacrylate (GMA) and ethylene dimethacrylate (EDMA) in the presence of a binary porogenic mixture of dodecanol and cyclohexanol, followed by ammonia solution treatment, glutaraldehyde activation and trypsin modification. The choice of acrylamide as co‐monomer was found useful to improve the efficiency of trypsin modification, thus, to increase the enzyme activity. The optimized microreactor offered very low back pressure, enabling the fast digestion of proteins flowing through the reactor. The performance of the monolithic microreactor was demonstrated with the digestion of cytochrome c at high flow rate. The digests were then characterized by CE and HPLC‐MS/MS with the sequence coverage of 57.7%. The digestion efficiency was found over 230 times as high as that of the conventional method. In addition, for the first time, protein digestion carried out in a mixture of water and ACN was compared with the conventional aqueous reaction using MS/MS detection, and the former solution was found more compatible and more efficient for protein digestion.

[1]  S. Ekström,et al.  Improved performance in silicon enzyme microreactors obtained by homogeneous porous silicon carrier matrix. , 2002, Talanta.

[2]  L. Locascio,et al.  Integrated microfluidic system enabling protein digestion, peptide separation, and protein identification. , 2001, Analytical chemistry.

[3]  R. Zeng,et al.  Identification of differentially expressed proteins between human hepatoma and normal liver cell lines by two‐dimensional electrophoresis and liquidchromatography‐ion trap mass spectrometry , 2000 .

[4]  Regine M. Schoenherr,et al.  On‐line protein digestion and peptide mapping by capillary electrophoresis with post‐column labeling for laser‐induced fluorescence detection , 2004, Electrophoresis.

[5]  J. Ramsey,et al.  On-chip proteolytic digestion and analysis using "wrong-way-round" electrospray time-of-flight mass spectrometry. , 2001, Analytical chemistry.

[6]  Frantisek Svec,et al.  Dual-function microanalytical device by in situ photolithographic grafting of porous polymer monolith: integrating solid-phase extraction and enzymatic digestion for peptide mass mapping. , 2003, Analytical chemistry.

[7]  Kazunori Yamada,et al.  Retention and reusability of trypsin activity by covalent immobilization onto grafted polyethylene plates , 2003 .

[8]  H. Zou,et al.  Protein A immobilized monolithic capillary column for affinity chromatography , 2002 .

[9]  F. Regnier,et al.  Protein proteolysis and the multi-dimensional electrochromatographic separation of histidine-containing peptide fragments on a chip. , 2003, Journal of chromatography. A.

[10]  D. Kiehl,et al.  Separation and characterization of the tryptic peptide mapping of recombinant bovine growth hormone by reversed-phase high-performance liquid chromatography electrospray mass spectrometry. , 1997, Rapid communications in mass spectrometry : RCM.

[11]  D. Josić,et al.  Monoliths as stationary phases for separation of proteins and polynucleotides and enzymatic conversion. , 2001, Journal of chromatography. B, Biomedical sciences and applications.

[12]  J. Fréchet,et al.  Design of reactive porous polymer supports for high throughput bioreactors: poly(2-vinyl-4,4-dimethylazlactone-co-acrylamide- co-ethylene dimethacrylate) monoliths. , 1999, Biotechnology and bioengineering.

[13]  J. Yates Mass spectrometry and the age of the proteome. , 1998, Journal of mass spectrometry : JMS.

[14]  T. Rohr,et al.  High-throughput peptide mass mapping using a microdevice containing trypsin immobilized on a porous polymer monolith coupled to MALDI TOF and ESI TOF mass spectrometers. , 2002, Journal of proteome research.

[15]  Frank Wedekind,et al.  Immobilized Enzymes: Methods and Applications , 1999 .

[16]  Masaru Kato,et al.  Creation of an on-chip enzyme reactor by encapsulating trypsin in sol-gel on a plastic microchip. , 2003, Analytical chemistry.

[17]  T. Toyo’oka,et al.  On-line trypsin-encapsulated enzyme reactor by the sol-gel method integrated into capillary electrophoresis. , 2002, Analytical chemistry.

[18]  G. Massolini,et al.  Development of a bioreactor based on trypsin immobilized on monolithic support for the on-line digestion and identification of proteins. , 2004, Journal of chromatography. A.

[19]  Dynamic changes of [Ca2+]i in cerebellar granule cells exposed to pulsed electric fields , 2000, Science in China Series C: Life Sciences.

[20]  G. Schwert,et al.  A spectrophotometric determination of trypsin and chymotrypsin. , 1955, Biochimica et biophysica acta.

[21]  K. Waldron,et al.  Reproducibility of a solid-phase trypsin microreactor for peptide mapping by capillary electrophoresis , 2000 .

[22]  D. Schriemer,et al.  On-column digestion of proteins in aqueous-organic solvents. , 2003, Rapid communications in mass spectrometry : RCM.

[23]  M Petro,et al.  Immobilization of trypsin onto “molded” macroporous poly(glycidyl methacrylate‐co‐ethylene dimethacrylate) rods and use of the conjugates as bioreactors and for affinity chromatography , 2000, Biotechnology and bioengineering.

[24]  Frantisek Svec,et al.  Enzymatic microreactor-on-a-chip: protein mapping using trypsin immobilized on porous polymer monoliths molded in channels of microfluidic devices. , 2002, Analytical chemistry.

[25]  Cheng S. Lee,et al.  Membrane-based nanoscale proteolytic reactor enabling protein digestion, peptide separation, and protein identification using mass spectrometry. , 2003, Analytical chemistry.

[26]  M. Novotny,et al.  Analytical characterization of a facile porous polymer monolithic trypsin microreactor enabling peptide mass mapping using mass spectrometry. , 2004, Rapid communications in mass spectrometry : RCM.

[27]  James P Landers,et al.  A microchip-based proteolytic digestion system driven by electroosmotic pumping. , 2003, Lab on a chip.

[28]  Pengyuan Yang,et al.  On-line preconcentration of in-gel digest by ion-exchange chromatography for protein identification using high-performance liquid chromatography-electrospray ionization tandem mass spectrometry. , 2003, Analytical biochemistry.

[29]  S. Patterson,et al.  Automated LC-LC-MS-MS platform using binary ion-exchange and gradient reversed-phase chromatography for improved proteomic analyses. , 2001, Journal of Chromatography B: Biomedical Sciences and Applications.

[30]  Jean M. J. Fréchet,et al.  New Designs of Macroporous Polymers and Supports: From Separation to Biocatalysis , 1996, Science.

[31]  H. Zou,et al.  High-performance affinity chromatography with immobilization of protein A and L-histidine on molded monolith. , 2002, Biotechnology and bioengineering.