Superconducting Transition Edge Sensor for Gamma-Ray Spectroscopy

Superconducting Transition edge sensor (TES) coupled with a heavy metal absorber is a promising microcalorimeter for Gammaray (γ-ray) spectroscopy with ultra-high energy resolution and high detection efficiency. It is very useful for the non-destructed inspection of the nuclide materials. High resolving power of γ-ray peaks can precisely identify multiple nuclides such as Plutonium (Pu) and Actinides with high efficiency and safety. For this purpose, we have developed the TES coupled with a tin absorber. We suggest the new device structure using the gold bump post which connects a tin absorber to the thermometer of the superconducting Ir/Au bilayer. High thermal conductivity of the gold bump post realized strong thermal coupling between the thermometer and the γ-ray absorber, and it brought the benefit of large pulse height and fast decay time. Our TES achieved the good energy resolution of 84 eV FWHM at 59.5 keV. Using this TES device, we also succeeded to demonstrate the nuclear material measurements. In the measurement of a Pu sample, we detected the sharp γ-ray peaks from 239Pu and 240Pu, and of a Fission Products (FP) sample, we observed fluorescence X-ray peaks emitted by the elements contained in FP. The TES could resolve the fine structures of each fluorescence X-ray line like Kα1 and Kα2. In addition to that, we developed the TES coupled with tantalum absorber, which is expected to have higher absorption efficiency for γ-rays. This device reported the best energy resolution of 465 eV at 662 keV. key words: transition edge sensor, gamma-ray, nuclide analysis

[1]  C. Otani,et al.  High Energy Gamma-Ray Spectroscopy Using Transition-Edge Sensor With a Superconducting Bulk Tantalum Absorber , 2015, IEEE Transactions on Applied Superconductivity.

[2]  Joel N. Ullom,et al.  Identification and elimination of anomalous thermal decay in gamma-ray microcalorimeters , 2013 .

[3]  C. Otani,et al.  Development of Hard X-ray and Gamma-ray Detector With Transition Edge Sensor for Nuclear Materials Analysis , 2015, IEEE Transactions on Applied Superconductivity.

[4]  Andrew S. Hoover,et al.  Superconducting absorbers for use in ultra-high resolution gamma-ray spectrometers based on low temperature microcalorimeter arrays , 2007 .

[5]  C. Otani,et al.  Development of Hard X-Ray and Gamma-Ray Spectrometer Using Superconducting Transition Edge Sensor , 2013, IEEE Transactions on Applied Superconductivity.

[6]  C. Otani,et al.  Development of Bulk Superconducting-Absorber Coupled Transition-Edge Sensor Detectors for Positron Annihilation Spectroscopy , 2013, IEEE Transactions on Applied Superconductivity.

[7]  Chiko Otani,et al.  Gamma-Ray Spectrometer based on a Transition Edge Sensor for Nuclear Materials Analysis , 2014 .

[8]  G. Hilton,et al.  X‐ray detection using a superconducting transition‐edge sensor microcalorimeter with electrothermal feedback , 1996 .

[9]  H. Takahashi,et al.  Development of a Gamma-Ray Detector With Iridium Transition Edge Sensor Coupled to a Pb Absorber , 2009, IEEE Transactions on Applied Superconductivity.

[10]  Hiroyuki Takahashi,et al.  X-ray Microcalorimeter Based on Superconducting Transition Edge Sensors , 2008, Analytical sciences : the international journal of the Japan Society for Analytical Chemistry.

[11]  Hiroyuki Takahashi,et al.  Development of Transition Edge Sensor Gamma-Ray Detectors for Positron-Annihilation-Spectroscopy , 2008 .

[12]  D. T. Vo,et al.  Determination of Plutonium Isotopic Content by Microcalorimeter Gamma-Ray Spectroscopy , 2013, IEEE Transactions on Nuclear Science.

[13]  Lynn,et al.  Increased Elemental Specificity of Positron Annihilation Spectra. , 1996, Physical review letters.