Pilot-Scale Evaluation of an Incinerability Ranking System for Hazardous Organic Compounds

The U.S. Environmental Protection Agency’s (EPA) hazardous waste incinerator performance standards specify a minimum destruction and removal efficiency (DRE) for principal organic hazardous constituents (POHCs) designated in the incinerator waste feed. In the past, selection of appropriate POHCs for incinerator trial burns has been based largely on their heats of combustion. Attempting to improve upon this approach, the University of Dayton Research Institute (UDRI), under contract to the EPA Risk Reduction Engineering Laboratory, has developed a thermal stability-based ranking of compound "incinerability". The subject study was conducted to evaluate the laboratory-developed ranking system in a pilot-scale incinerator. Mixtures of POHCs, spanning the ranking scale from most- to least-difficult to destroy (Class 1 to Class 7, respectively), were prepared and combined with a clay-based sorbent matrix. These mixtures were then fed into the rotary kiln incineration system at the U.S. EPA Incineration Research...