A comparison of the Invos 3100 and the Critikon 2020 near‐infrared spectrophotometers as monitors of cerebral oxygenation

Assessment of cerebral oxygenation using near‐infrared spectroscopy in intensive care is increasing. We compared the ability of the Invos 3100 and the Critikon 2020 monitors to produce stable and consistent readings of regional cerebral oxygen saturation in resting volunteers. Failure to obtain any stable reading with the Critikon occurred in eight out of 18 subjects (44.4%) and with the Invos in three out of 15 subjects (20%). The Critikon showed a significantly higher failure rate in male subjects (p = 0.0011). Differences in recorded values of cerebral oxygen saturation (Critikon − Invos) ranged from −4.7% to 12.6% and were significantly related to the average saturation level (p < 0.0001). The within‐monitor variability was significantly higher for the Invos (p = 0.0124). Neither monitor is able to give stable and consistent readings over time, particularly in male subjects. The unacceptably high failure rate of the recently introduced Critikon 2020 will limit or prevent its clinical use.

[1]  M. Copet,et al.  A Monte Carlo investigation of optical pathlength in inhomogeneous tissue and its application to near-infrared spectroscopy , 1993 .

[2]  F. Jöbsis Noninvasive, infrared monitoring of cerebral and myocardial oxygen sufficiency and circulatory parameters. , 1977, Science.

[3]  S. M. Bailey,et al.  Near infrared spectroscopy in adults , 1993, Anaesthesia.

[4]  Somanetics INVOS 3100 cerebral oximeter. , 1994 .

[5]  D T Delpy,et al.  Cerebral monitoring in newborn infants by magnetic resonance and near infrared spectroscopy. , 1987, Scandinavian journal of clinical and laboratory investigation. Supplementum.

[6]  J. Brazy,et al.  Noninvasive monitoring of cerebral oxygenation in preterm infants: preliminary observations. by brazy je, lewis dv, mitnick mh, and joubsis vander vliet ff. pediatrics 1985; 75:217–225 , 1985, Pediatrics.

[7]  B. Oeseburg,et al.  A comparative study of two near infrared spectrophotometers for the assessment of cerebral haemodynamics , 1995, Acta anaesthesiologica Scandinavica. Supplementum.

[8]  Susan Wray,et al.  QUANTIFICATION OF CEREBRAL OXYGENATION AND HAEMODYNAMICS IN SICK NEWBORN INFANTS BY NEAR INFRARED SPECTROPHOTOMETRY , 1986, The Lancet.

[9]  A. Mortimer,et al.  Cerebral hypoxia detected by near infrared spectroscopy , 1994, Anaesthesia.

[10]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[11]  S. Zeger,et al.  Longitudinal data analysis using generalized linear models , 1986 .

[12]  J. Keen,et al.  A study of the differences between male and female skulls. , 1950, American journal of physical anthropology.

[13]  G. Mead,et al.  Cerebral oximetry: a useful monitor during carotid artery surgery , 1996, Anaesthesia.

[14]  K. Slavin,et al.  Somanetics INVOS 3100 cerebral oximeter. , 1995, Neurosurgery.

[15]  J D Pickard,et al.  Near-infrared spectroscopy use in patients with head injury. , 1995, Journal of neurosurgery.

[16]  Near infrared spectroscopy , 1994 .