Abstract A passive direct methanol fuel cell (DMFC) stack that consists of six unit cells was designed, fabricated, and tested. The stack was tested with different methanol concentrations under ambient conditions. It was found that the stack performance increased when the methanol concentration inside the fuel tank was increased from 2.0 to 6.0 M. The improved performance is primarily due to the increased cell temperature as a result of the exothermic reaction between the permeated methanol and oxygen on the cathode. Moreover, the increased cell temperature enhanced the water evaporation rate on the air-breathing cathode, which significantly reduced water flooding on the cathode and further improved the stack performance. This passive DMFC stack, providing 350 mW at 1.8 V, was successfully applied to power a seagull display kit. The seagull display kit can continuously run for about 4 h on a single charge of 25 cm 3 4.0-M methanol solution.

[1]  M. Aulice Scibioh,et al.  On the consequences of methanol crossover in passive air-breathing direct methanol fuel cells , 2005 .

[2]  Eugene S. Smotkin,et al.  Methanol crossover in direct methanol fuel cells: a link between power and energy density , 2002 .

[3]  Rong Chen,et al.  Effect of cell orientation on the performance of passive direct methanol fuel cells , 2006 .

[4]  Zhigang Qi,et al.  Open circuit voltage and methanol crossover in DMFCs , 2002 .

[5]  Electrochemical Reactions in a DMFC under Open-Circuit Conditions , 2005 .

[6]  W. Vielstich,et al.  Investigation of methanol crossover and single electrode performance during PEMDMFC operation: A study using a solid polymer electrolyte membrane fuel cell system , 1998 .

[7]  Rong Chen,et al.  A novel electrode architecture for passive direct methanol fuel cells , 2007 .

[8]  Christopher K. Dyer Fuel cells for portable applications , 2002 .

[9]  Rong Chen,et al.  Porous current collectors for passive direct methanol fuel cells , 2007 .

[10]  C. Chen,et al.  Performance of an air-breathing direct methanol fuel cell , 2003 .

[11]  Hyuk Chang,et al.  Membrane electrode assembly for passive direct methanol fuel cells , 2006 .

[12]  Rong Chen,et al.  Effect of membrane thickness on the performance and efficiency of passive direct methanol fuel cells , 2006 .

[13]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[14]  D. Chu,et al.  Comparative Studies of Methanol Crossover and Cell Performance for a DMFC , 2004 .

[15]  H. Ha,et al.  Behavioral pattern of a monopolar passive direct methanol fuel cell stack , 2006 .

[16]  Addition of non-reacting gases to the anode flow field of DMFCs leading to improved performance , 2004 .

[17]  Jaesung Han,et al.  Direct methanol fuel-cell combined with a small back-up battery , 2002 .

[18]  Rong Chen,et al.  The effect of methanol concentration on the performance of a passive DMFC , 2005 .

[19]  Rong Chen,et al.  Mathematical modeling of a passive-feed DMFC with heat transfer effect , 2005 .

[20]  T. Zhao,et al.  Synthesis and physical/electrochemical characterization of Pt/C nanocatalyst for polymer electrolyte fuel cells , 2004 .

[21]  Jiujun Zhang,et al.  Design and testing of a passive planar three-cell DMFC , 2007 .

[22]  Shimshon Gottesfeld,et al.  Methanol transport through Nafion membranes : Electro-osmotic drag effects on potential step measurements , 2000 .

[23]  Hong Chang,et al.  Materials and processes for small fuel cells , 2002 .

[24]  Toshiyuki Momma,et al.  Design and fabrication of pumpless small direct methanol fuel cells for portable applications , 2004 .