Biotribometer for Assessment of Cell and Tissue Toxicity of Orthopedic Metal Implant Debris.

[1]  Y. Berthier,et al.  Tribocorrosion of Polyethylene/Cobalt Contact Combined with Real-Time Fluorescence Assays on Living Macrophages: Development of A Multidisciplinary Biotribocorrosion Device , 2019, Biotribology.

[2]  M. Laurent,et al.  Investigation of CoCrMo material loss in a novel bio-tribometer designed to study direct cell reaction to wear and corrosion products. , 2019, Biotribology.

[3]  Michael J Wiegand,et al.  Electrochemical potential zone of viability on CoCrMo surfaces is affected by cell type: Macrophages under cathodic bias are more resistant to killing. , 2018, Journal of biomedical materials research. Part A.

[4]  S. Mischler,et al.  Assessment of a recent tribocorrosion model for wear of metal-on-metal hip joints: Comparison between model predictions and simulator results , 2016 .

[5]  R. Heuberger,et al.  Development of a Synthetic Synovial Fluid for Tribological Testing , 2015 .

[6]  A. I. Muñoz,et al.  Electrochemical Quartz Crystal Microbalance and X-Ray Photoelectron Spectroscopy study of cathodic reactions in Bovine Serum Albumin containing solutions on a Physical Vapour Deposition-CoCrMo biomedical alloy , 2015 .

[7]  S. Mischler,et al.  Tribocorrosion of passive metals in the mixed lubrication regime: theoretical model and application to metal-on-metal artificial hip joints , 2015 .

[8]  H. Matusiewicz Potential release of in vivo trace metals from metallic medical implants in the human body: from ions to nanoparticles--a systematic analytical review. , 2014, Acta biomaterialia.

[9]  A. I. Muñoz,et al.  Wear of CoCrMo alloys used in metal-on-metal hip joints: A tribocorrosion appraisal , 2013 .

[10]  J. Powell,et al.  Cobalt from metal-on-metal hip replacements may be the clinically relevant active agent responsible for periprosthetic tissue reactions. , 2012, Acta biomaterialia.

[11]  M. Wimmer,et al.  Wear-Corrosion Synergism in a CoCrMo Hip Bearing Alloy Is Influenced by Proteins , 2012, Clinical orthopaedics and related research.

[12]  M. Wimmer,et al.  Construction of a tribocorrosion test apparatus for the hip joint: Validation, test methodology and analysis , 2011 .

[13]  J. Powell,et al.  The chemical form of metallic debris in tissues surrounding metal-on-metal hips with unexplained failure. , 2010, Acta biomaterialia.

[14]  L. Filgueira,et al.  Metal is not inert: role of metal ions released by biocorrosion in aseptic loosening--current concepts. , 2009, Journal of biomedical materials research. Part A.

[15]  Stefano Mischler,et al.  Passive and transpassive behaviour of CoCrMo in simulated biological solutions , 2004 .

[16]  D. Zukor,et al.  Size, shape, and composition of wear particles from metal-metal hip simulator testing: effects of alloy and number of loading cycles. , 2003, Journal of biomedical materials research. Part A.

[17]  J. Jacobs,et al.  Metal sensitivity in patients with orthopaedic implants. , 2001, The Journal of bone and joint surgery. American volume.

[18]  Stanley A. Brown,et al.  Distribution of cobalt chromium wear and corrosion products and biologic reactions. , 1996, Clinical orthopaedics and related research.

[19]  S. Brown,et al.  Cellular uptake of titanium and vanadium from addition of salts or fretting corrosion in vitro. , 1994, Journal of biomedical materials research.

[20]  Stanley A. Brown,et al.  Cell association of fretting corrosion products generated in a cell culture , 1991, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[21]  P. Srinivasa Pai,et al.  Significance of Tribocorrosion in Biomedical Applications: Overview and Current Status , 2009 .

[22]  A. P. Serro,et al.  Friction and wear mechanisms in hip prosthesis: Comparison of joint materials behaviour in several lubricants , 2006 .