Drop-in energy performance evaluation of R1234yf and R1234ze(E) in a vapor compression system as R134a replacements

This paper presents an energy performance evaluation of two low-GWP refrigerants, R1234yf and R1234ze(E), as drop-in replacements for R134a. Tests are carried out in a monitored vapor compression system combining different values of evaporation and condensation temperature, and without/with the adoption of an internal heat exchanger. The parameters analyzed are volumetric efficiency, cooling capacity and COP and they are presented taking R134a as baseline. Results show that without IHX the average volumetric efficiency for R1234yf and R1234ze is 4% and 5% lower compared with R134a. The cooling capacity obtained with R1234yf and R1234ze is reduced, with an average difference of 9% and 30% without IHX. Also, COP values are about 7% lower for R1234yf and 6% lower for R1234ze than those obtained using R134a. Finally, the use of an internal heat exchanger reduces the COP differences for both replacements.

[1]  Kim Choon Ng,et al.  Study on activated carbon/HFO-1234ze(E) based adsorption cooling cycle , 2013 .

[2]  Benedick Montreal Protocol on Substances that Deplete the Ozone Layer , 1996 .

[3]  Omar Abdelaziz,et al.  Experimental Performance of R-1234yf and R-1234ze as Drop-in Replacements for R-134a in Domestic Refrigerators , 2012 .

[4]  Chi-Chuan Wang An overview for the heat transfer performance of HFO-1234yf , 2013 .

[5]  R. Akasaka Thermodynamic property models for the difluoromethane (R-32) + trans-1,3,3,3-tetrafluoropropene (R-1234ze(E)) and difluoromethane + 2,3,3,3-tetrafluoropropene (R-1234yf) mixtures , 2013 .

[6]  Mark W. Spatz,et al.  Analysis of low-GWP alternatives for small refrigeration (plugin) applications. , 2010 .

[7]  Kenji Takizawa,et al.  Effect of high humidity on flammability property of a few non-flammable refrigerants , 2014 .

[8]  Joaquín Navarro-Esbrí,et al.  Experimental analysis of the internal heat exchanger influence on a vapour compression system performance working with R1234yf as a drop-in replacement for R134a , 2013 .

[9]  S. Kondo,et al.  Effects of temperature and humidity on the flammability limits of several 2L refrigerants , 2012 .

[10]  A. Haines Climate change 2001: the scientific basis. Contribution of Working Group 1 to the Third Assessment report of the Intergovernmental Panel on Climate Change [Book review] , 2003 .

[11]  Chaobin Dang,et al.  Vapor-liquid equilibrium measurements for binary mixtures of R1234yf with R32, R125, and R134a , 2013 .

[12]  Jadran Vrabec,et al.  Description of HFO-1234yf with BACKONE equation of state , 2011 .

[13]  Reinhard Radermacher,et al.  Potential benefits of saturation cycle with two-phase refrigerant injection , 2013 .

[14]  Claudio Zilio,et al.  The refrigerant R1234yf in air conditioning systems , 2011 .

[15]  Sad Jarall,et al.  Study of refrigeration system with HFO-1234yf as a working fluid , 2012 .

[16]  James M. Calm THE NEXT GENERATION OF REFRIGERANTS , 2007 .

[17]  Shigeru Koyama,et al.  Drop-in Experiments on Heat Pump Cycle Using HFO-1234ze(E) and Its Mixtures with HFC-32 , 2010 .

[18]  Omar Abdelaziz,et al.  Experimental Performance of R-1234yf as a Drop-in Replacement for R-134a in Domestic Refrigerators , 2012 .

[19]  S. Koyama,et al.  Low GWP refrigerants R1234ze(E) and R1234ze(Z) for high temperature heat pumps , 2014 .

[20]  J. Navarro-Esbrí,et al.  Experimental analysis of R1234yf as a drop-in replacement for R134a in a vapor compression system , 2013 .

[21]  Piotr A. Domanski,et al.  A thermodynamic analysis of refrigerants: Possibilities and tradeoffs for Low-GWP refrigerants ☆ , 2014 .

[22]  Honghyun Cho,et al.  Performance characteristics of an automobile air conditioning system with internal heat exchanger using refrigerant R1234yf , 2013 .

[23]  Vincent Lemort,et al.  Thermo-economic optimization of waste heat recovery Organic Rankine Cycles , 2011 .

[24]  Ryo Akasaka,et al.  Measurements of saturated densities and critical parameters for the binary mixture of 2,3,3,3-tetrafluoropropene (R-1234yf) + difluoromethane (R-32) , 2013 .

[25]  Bipin Kumar Yadav,et al.  Theoretical Exergy Analysis of HFO-1234 yf and HFO-1234 ze as an Alternative Replacement of HFC-134 a in Simple Vapour Compression Refrigeration System , 2013 .

[26]  Z. Qi Experimental study on evaporator performance in mobile air conditioning system using HFO-1234yf as working fluid , 2013 .

[27]  John R. Thome,et al.  Flow pattern map, heat transfer and pressure drops during evaporation of R-1234ze(E) and R134a in a horizontal, circular smooth tube: Experiments and assessment of predictive methods , 2013 .

[28]  Dongsoo Jung,et al.  A brief performance comparison of R1234yf and R134a in a bench tester for automobile applications , 2012 .

[29]  J. Navarro-Esbrí,et al.  Shell-and-tube evaporator model performance with different two-phase flow heat transfer correlations. Experimental analysis using R134a and R1234yf , 2014 .

[30]  S. Koyama,et al.  Flow boiling of non-azeotropic mixture R32/R1234ze(E) in horizontal microfin tubes , 2013 .

[31]  N. Lai,et al.  Equations of state for HFO-1234ze(E) and their application in the study on refrigeration cycle , 2014 .

[32]  Kim Choon Ng,et al.  A corresponding states treatment of the liquid–vapor saturation line , 2012 .

[33]  Omar Abdelaziz,et al.  Advances in household appliances- A review , 2011 .

[34]  S. Kondo,et al.  Flammability limits of binary mixtures of ammonia with HFO-1234yf, HFO-1234ze, HFC-134a, and HFC-125 , 2013 .

[35]  Ilmutdin M. Abdulagatov,et al.  Viscosity measurements for 2,3,3,3-tetrafluoroprop-1-ene (R1234yf) and trans-1,3,3,3-tetrafluoropropene (R1234ze(E)) , 2013 .

[36]  Aleksandra Borsukiewicz-Gozdur,et al.  Pumping work in the organic Rankine cycle , 2013 .

[37]  A. Cavallini,et al.  Thermodynamic properties of eight fluorinated olefins , 2010 .