A customized bioimpedance meter for monitoring insulin bioavailability

In this work, an instrument to measure the bioimpedance is presented for monitoring insulin bioavailability. The instrument is non-invasive, it is built with off-the-shelf components, and it exploits electrodes with a gel film. This hardware, already successfully used in biomedical applications, is now proposed for identification of a personalized insulin model by evaluating in real-time the impedance variation in injection site. A preliminary experimental campaign was conducted on eggplants, in order to evaluate the instrument employability. The final purpose is to integrate the instrument in modern artificial pancreas and to achieve a customized drug therapy.

[1]  Andrea Facchinetti,et al.  Continuous Glucose Monitoring Sensors: Past, Present and Future Algorithmic Challenges , 2016, Sensors.

[2]  Domenico Grimaldi,et al.  Instrumentation and measurement in medical, biomedical, and healthcare systems , 2016, IEEE Instrum. Meas. Mag..

[3]  B. Riccò,et al.  Electrical impedance spectroscopy (EIS) for biological analysis and food characterization: a review , 2017 .

[5]  Yukiharu Ogawa,et al.  Electrical impedance spectroscopy analysis of eggplant pulp and effects of drying and freezing–thawing treatments on its impedance characteristics , 2008 .

[6]  P. Scherer,et al.  Selective enhancement of insulin sensitivity in the mature adipocyte is sufficient for systemic metabolic improvements , 2015, Nature Communications.

[7]  Pasquale Arpaia,et al.  An instrument for prosthesis osseointegration assessment by electrochemical impedance spectrum measurement , 2008 .

[8]  Pasquale Arpaia,et al.  Measuring the drug absorbed by biological tissues in laboratory emulation of dermatological topical treatments , 2016, 2016 IEEE International Symposium on Medical Measurements and Applications (MeMeA).

[9]  Antonino S. Fiorillo,et al.  Low-Frequency Ultrasound in Medicine: An In Vivo Evaluation , 2012, IEEE Transactions on Instrumentation and Measurement.

[10]  Tim Nolan,et al.  International Diabetes Federation. , 2013, Diabetes research and clinical practice.

[11]  B Shashaj,et al.  Benefits of a bolus calculator in pre‐ and postprandial glycaemic control and meal flexibility of paediatric patients using continuous subcutaneous insulin infusion (CSII) , 2008, Diabetic medicine : a journal of the British Diabetic Association.

[12]  R. Young,et al.  Diabetic Lipohypertrophy Delays Insulin Absorption , 1984, Diabetes Care.

[13]  Pasquale Arpaia,et al.  Noninvasive measurement of transdermal drug delivery by impedance spectroscopy , 2017, Scientific Reports.

[14]  C. Denecke The bionic pancreas: novel perspectives on insulin replacement therapies. , 2015, Transplantation.

[15]  Marco Parvis,et al.  Low-Cost Impedance Spectroscopy System Based on a Logarithmic Amplifier , 2015, IEEE Transactions on Instrumentation and Measurement.

[16]  E. Mosekilde,et al.  Bioavailability and variability of biphasic insulin mixtures. , 2012, European journal of pharmaceutical sciences : official journal of the European Federation for Pharmaceutical Sciences.

[17]  Feng Dong,et al.  A Wideband Electrical Impedance Tomography System Based on Sensitive Bioimpedance Spectrum Bandwidth , 2020, IEEE Transactions on Instrumentation and Measurement.

[18]  R. Hovorka,et al.  Artificial pancreas treatment for outpatients with type 1 diabetes: systematic review and meta-analysis , 2018, British Medical Journal.

[19]  C. Cobelli,et al.  Time Lag of Glucose From Intravascular to Interstitial Compartment in Humans , 2013, Diabetes.

[20]  Christina G. Siontorou,et al.  Carbohydrate Detection Failure Analysis via Biosensoring , 2008, 2006 IEEE Instrumentation and Measurement Technology Conference Proceedings.

[21]  E. Topsakal,et al.  Design of a Dual-Band Implantable Antenna and Development of Skin Mimicking Gels for Continuous Glucose Monitoring , 2008, IEEE Transactions on Microwave Theory and Techniques.

[22]  Richard D. Beach,et al.  Subminiature implantable potentiostat and modified commercial telemetry device for remote glucose monitoring , 1999, IEEE Trans. Instrum. Meas..

[23]  Anshu M. Gupta,et al.  Current Diabetes Technology: Striving for the Artificial Pancreas , 2019, Diagnostics.

[24]  Jaime Velasco-Medina,et al.  Structured Approach and Impedance Spectroscopy Microsystem for Fractional-Order Electrical Characterization of Vegetable Tissues , 2020, IEEE Transactions on Instrumentation and Measurement.

[25]  Howard C. Zisser,et al.  Feasibility of Outpatient Fully Integrated Closed-Loop Control , 2013, Diabetes Care.

[26]  M. Afsar,et al.  Millimeter and Submillimeter Wave Dielectric Measurements of Household Powders Using Fourier Transform Spectroscopy , 2006, 2006 IEEE Instrumentation and Measurement Technology Conference Proceedings.

[27]  Y. Bao,et al.  Fibroblast growth factor 21 increases insulin sensitivity through specific expansion of subcutaneous fat , 2018, Nature Communications.

[28]  Sachin Kumar,et al.  Realization of Four-Terminal-Pair Capacitors as Reference Standards of Impedance at High Frequency Using Impedance-Matrix Method , 2017, IEEE Transactions on Instrumentation and Measurement.

[29]  Marco Parvis,et al.  Inertial measurement system for swimming rehabilitation , 2017, 2017 IEEE International Symposium on Medical Measurements and Applications (MeMeA).