Implementations of Maximum-Likelihood Position Estimation in a Four-PMT Scintillation Detector

Maximum-likelihood (ML) position estimation in small scintillation detectors often involves the use of a look-up table (LUT) to map event characterization vectors to the associated position estimates. As the number of possible characterization vectors determines the size of the LUT, the number of these vectors needs to be manageable. This implies that a critical component of an implementation of ML position estimation is the mapping of detector output signals to characterization vectors. The use of different photomultiplier tube (PMT) output mappings in ML estimation in a small camera with four round PMTs and a single 5 x 100 x 100 mm NaI(T1) crystal was investigated. The employed mappings of the four detector signals resulted in 20 (5 bits/PMT), 22 (8 bits each for Anger x and y; 6 bits for the sum signal), 24 (6 bits/PMT), and 28 (7 bits/PMT) bit event characterizations. Using present implementations of ML estimation, significant improvement in image quality results if a 24-bit characterization is used rather than 20 or 22. Improvement in image quality is not as marked when 28-bit characterization is used instead of 24, but measurable improvement is obtained.

[1]  Jyhcheng. Chen,et al.  Modular gamma cameras: Improvements in scatter rejection, and characterization and initial clinical application. , 1995 .

[2]  W. Chang,et al.  BAR-detector with extended field of view for a modular SPECT system , 1992, IEEE Conference on Nuclear Science Symposium and Medical Imaging.

[3]  Thomas D Milster,et al.  Design and Construction of a Modular Gamma Camera , 1987 .

[4]  Kenneth F. Koral,et al.  A Hybrid Maximum Likelihood Position Computer for Scintillation Cameras , 1987, IEEE Transactions on Nuclear Science.

[5]  L. S. Mar,et al.  Estimation and control of the mean response of photomultiplier tubes , 1989 .

[6]  J N Aarsvold,et al.  A Miniature Gamma Camera a , 1994, Annals of the New York Academy of Sciences.

[7]  J N Aarsvold,et al.  A miniature gamma camera. , 1994, Annals of the New York Academy of Sciences.

[8]  R. H. Seacat,et al.  Digital Position Estimation for the Modular Scintillation Camera , 1985, IEEE Transactions on Nuclear Science.

[9]  R. G. Simpson,et al.  A Modular Scintillation Camera for Use in Nuclear Medicine , 1984, IEEE Transactions on Nuclear Science.

[10]  Harrison H. Barrett,et al.  Likelihood window, energy window, and Bayesian window for scatter rejection in gamma cameras , 1993, 1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference.

[11]  H H Barrett,et al.  A full-field modular gamma camera. , 1990, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[12]  Hope Ann Marcotte Expectation maximization methods for processing SPECT images , 1993 .

[13]  Harrison H. Barrett,et al.  Modular Scintillation Cameras: A Progress Report , 1988, Medical Imaging.

[14]  Kenneth F. Koral,et al.  Recursive calculation of the two-dimensional maximum likelihood position estimate for a scintillation camera , 1990 .

[15]  Robert M. Gray,et al.  Maximum a Posteriori Estimation of Position in Scintillation Cameras , 1976, IEEE Transactions on Nuclear Science.

[16]  Luc Laperrière,et al.  Maximum likelihood positioning in the scintillation camera using depth of interaction , 1991, Conference Record of the 1991 IEEE Nuclear Science Symposium and Medical Imaging Conference.

[17]  J.A. Fessler,et al.  Robust maximum-likelihood position estimation in scintillation cameras , 1991, Conference Record of the 1991 IEEE Nuclear Science Symposium and Medical Imaging Conference.