Transmission of Pathogenic Bacterial Organisms in the Anesthesia Work Area

Background:The current prevalence of hospital-acquired infections and evolving amplification of bacterial resistance are major public health concerns. A heightened awareness of intraoperative transmission of potentially pathogenic bacterial organisms may lead to implementation of effective preventative measures. Methods:Sixty-one operative suites were randomly selected for analysis. Sterile intravenous stopcock sets and two sites on the anesthesia machine were decontaminated and cultured aseptically at baseline and at case completion. The primary outcome was the presence of a positive culture on the previously sterile patient stopcock set. Secondary outcomes were the number of colonies per surface area sampled on the anesthesia machine, species identification, and antibiotic susceptibility of isolated organisms. Results:Bacterial contamination of the anesthesia work area increased significantly at the case conclusion, with a mean difference of 115 colonies per surface area sampled (95% confidence interval [CI], 62–169; P < 0.001). Transmission of bacterial organisms, including vancomycin-resistant enterococcus, to intravenous stopcock sets occurred in 32% (95% CI, 20.6–44.9%) of cases. Highly contaminated work areas increased the odds of stopcock contamination by 4.7 (95% CI, 1.42–15.42; P = 0.011). Contaminated intravenous tubing was associated with a trend toward increased nosocomial infection rates (odds ratio, 3.08; 95% CI, 0.56–17.5; P = 0.11) and with an increase in mortality (95% CI odds ratio, 1.11–∞; P = 0.0395). Conclusions:Potentially pathogenic, multidrug-resistant bacterial organisms are transmitted during the practice of general anesthesia to both the anesthesia work area and intravenous stopcock sets. Implementation of infection control measures in this area may help to reduce both the evolving problem of increasing bacterial resistance and the development of life-threatening infectious complications.

[1]  M. Beach,et al.  Insulin infusion improves neutrophil function in diabetic cardiac surgery patients. , 1999, Anesthesia and analgesia.

[2]  M. Gourdeau,et al.  A microbiological study of the contamination of the syringes used in anaesthesia practice , 1988, Canadian journal of anaesthesia = Journal canadien d'anesthesie.

[3]  J. L. Iribarren,et al.  The micro-organism responsible for central venous catheter related bloodstream infection depends on catheter site , 2006, Intensive Care Medicine.

[4]  E. Jaurrieta,et al.  Hub colonization as the initial step in an outbreak of catheter-related sepsis due to coagulase negative staphylococci during parenteral nutrition. , 1984, JPEN. Journal of parenteral and enteral nutrition.

[5]  L. Gentry,et al.  Reducing the Incidence of Nosocomial Pneumonia in Cardiovascular Surgery Patients , 2003, Quality management in health care.

[6]  D. Gould Nurses' hands as vectors of hospital-acquired infection: a review. , 1991, Journal of advanced nursing.

[7]  L. Vidaur,et al.  Colonization of the medial lumen is a risk factor for catheter-related bloodstream infection , 2006, Intensive Care Medicine.

[8]  D. Nafziger,et al.  Microbial growth on the anesthesia machine. , 2002, AANA journal.

[9]  M. Hayden Insights into the epidemiology and control of infection with vancomycin-resistant enterococci. , 2000, Clinical infectious diseases : an official publication of the Infectious Diseases Society of America.

[10]  J. Kaufman,et al.  Clinical experience with the multiple lumen central venous catheter. , 1986, JPEN. Journal of parenteral and enteral nutrition.

[11]  Roberta B Carey,et al.  Invasive methicillin-resistant Staphylococcus aureus infections in the United States. , 2007, JAMA.

[12]  R. Lütticken,et al.  Distribution of multi-resistant Gram-negative versus Gram-positive bacteria in the hospital inanimate environment. , 2004, The Journal of hospital infection.

[13]  R. Girard,et al.  [Surveillance of nosocomial infections related to anesthesia. A multicenter study]. , 2000, Annales francaises d'anesthesie et de reanimation.

[14]  J. Hajjar,et al.  Risque infectieux nosocomial en anesthésie. Recommandations générales , 1998 .

[15]  Z. Zuo,et al.  Bacterial Colonization of Epidural Catheters Used for Short-term Postoperative Analgesia: Microbiological Examination and Risk Factor Analysis , 2008, Anesthesiology.

[16]  N. Levy,et al.  Hand washing , 2004, Dental assistant.

[17]  Y Ohe,et al.  [Bacterial contamination of anesthesiologists' hands and the efficacy of handwashing]. , 1996, Masui. The Japanese journal of anesthesiology.

[18]  A. Saubermann,et al.  The Anesthesia Machine and Circle System Are Not Likely to be Sources of Bacterial Contamination , 1977, Anesthesiology.

[19]  D. Graham,et al.  Infectious complications among patients receiving home intravenous therapy with peripheral, central, or peripherally placed central venous catheters. , 1991, The American journal of medicine.

[20]  E. Nemergut,et al.  The Anesthesiologist's Role in the Prevention of Surgical Site Infections , 2006, Anesthesiology.

[21]  D. E. Saye Recurring and antimicrobial-resistant infections:considering the potential role of biofilms in clinical practice. , 2007, Ostomy/wound management.

[22]  M. Askarian,et al.  Survey on adoption of measures to prevent nosocomial infection by anaesthesia personnel. , 2002, Eastern Mediterranean health journal = La revue de sante de la Mediterranee orientale = al-Majallah al-sihhiyah li-sharq al-mutawassit.

[23]  L. Bland,et al.  Bloodstream infections associated with a needleless intravenous infusion system in patients receiving home infusion therapy. , 1995, JAMA.

[24]  Post-dural puncture bacterial meningitis. , 2006, Anesthesiology.

[25]  National Nosocomial Infections Surveillance (NNIS) System Report, data summary from January 1992 through June 2004, issued October 2004. , 2004, American journal of infection control.

[26]  D. Ottaviani,et al.  Catheter-related Bacteremia and Multidrug-resistant Acinetobacter lwoffii , 2007, Emerging infectious diseases.

[27]  A. Chan,et al.  Control and management of hospital indoor air quality. , 2006, Medical science monitor : international medical journal of experimental and clinical research.

[28]  S. Saint,et al.  Rates of infection for single-lumen versus multilumen central venous catheters: A meta-analysis , 2003, Critical care medicine.

[29]  S. Saint,et al.  The Clinical and Economic Consequences of Nosocomial Central Venous Catheter-Related Infection: Are Antimicrobial Catheters Useful? , 2000, Infection Control &#x0026; Hospital Epidemiology.

[30]  Dan M. Kluger,et al.  The risk of bloodstream infection in adults with different intravascular devices: a systematic review of 200 published prospective studies. , 2006, Mayo Clinic proceedings.

[31]  S. Saint,et al.  Cost-effectiveness of antiseptic-impregnated central venous catheters for the prevention of catheter-related bloodstream infection. , 1999, JAMA.

[32]  A. Casey,et al.  A prospective clinical trial to evaluate the microbial barrier of a needleless connector. , 2007, The Journal of hospital infection.

[33]  A. Ogawa,et al.  Prevention of catheter-related infections using a closed hub system in patients with pulmonary arterial hypertension. , 2007, Circulation journal : official journal of the Japanese Circulation Society.

[34]  D. Pittet,et al.  Compliance with hand disinfection and its impact on hospital-acquired infections. , 2001, The Journal of hospital infection.

[35]  R. D. McCormick,et al.  Guidelines for the prevention of intravascular catheter-related infections. The Hospital Infection Control Practices Advisory Committee, Center for Disease Control and Prevention, U.S. , 2002, Pediatrics.

[36]  J. Hajjar,et al.  Surveillance des infections nosocomiales liées à l'anesthésie. Étude multicentrique , 2000 .

[37]  E. Nováková,et al.  The role of non-critical health-care tools in the transmission of nosocomial infections. , 2005, Bratislavske lekarske listy.

[38]  M. W. Wood,et al.  Bacterial contamination of stethoscopes with antimicrobial diaphragm covers. , 2006, American journal of infection control.