Visual corona tests have been broadly applied for identifying the critical corona points of diverse high-voltage devices, although other approaches based on partial discharge or radio interference voltage measurements are also widely applied to detect corona activity. Nevertheless, these two techniques must be applied in screened laboratories, which are scarce and expensive, require sophisticated instrumentation, and typically do not allow location of the discharge points. This paper describes the detection of the visual corona and location of the critical corona points of a sphere-plane gap configurations under different pressure conditions ranging from 100 to 20 kPa, covering the pressures typically found in aeronautic environments. The corona detection is made with a low-cost CMOS imaging sensor from both the visible and ultraviolet (UV) spectrum, which allows detection of the discharge points and their locations, thus significantly reducing the complexity and costs of the instrumentation required while preserving the sensitivity and accuracy of the measurements. The approach proposed in this paper can be applied in aerospace applications to prevent the arc tracking phenomenon, which can lead to catastrophic consequences since there is not a clear protection solution, due to the low levels of leakage current involved in the pre-arc phenomenon.

[1]  Jon Raffe Willmott,et al.  Thermal Imaging Metrology with a Smartphone Sensor , 2018, Sensors.

[2]  Jordi-Roger Riba,et al.  Voltage Correction Factors for Air-Insulated Transmission Lines Operating in High-Altitude Regions to Limit Corona Activity: A Review , 2018, Energies.

[3]  M. Tabrizchi,et al.  Corona discharge ion mobility spectrometry at reduced pressures , 2004 .

[4]  A. Lichtenberg,et al.  Principles of Plasma Discharges and Materials Processing , 1994 .

[5]  Influence of pressure and humidity on the amplitude — Phase distribution of AC corona pulse , 2013, 2013 Annual Report Conference on Electrical Insulation and Dielectric Phenomena.

[6]  Zhong-Xin Li,et al.  Numerical calculation of the corona onset voltage for bundle conductors for HVDC transmission line , 2011 .

[7]  Jordi-Roger Riba,et al.  Simplification and cost reduction of visual corona tests , 2018 .

[8]  V. Herrero,et al.  Large effects of small pressure changes in the kinetics of low pressure glow discharges , 2011 .

[9]  Hai Long Pang,et al.  Corona Discharge and Electrostatic Precipitation in Carbon Dioxide Under Reduced Pressure Simulating Mars Atmosphere , 2005, IEEE Transactions on Industry Applications.

[10]  Xiang Cui,et al.  Influence of AC voltage on the positive DC corona current pulses in a wire-cylinder gap , 2016 .

[11]  F. Valensi,et al.  Energy losses from an arc tracking in aeronautic cables in DC circuits , 2013, IEEE Transactions on Dielectrics and Electrical Insulation.

[12]  E. Kyriakides,et al.  Partial discharge modeling: An advanced capacitive model of void , 2019, IEEE Transactions on Dielectrics and Electrical Insulation.

[13]  Martine Lienard,et al.  Characterization of the High-Frequency Conducted Electromagnetic Noise Generated by an Arc Tracking Between DC wires , 2016, IEEE Transactions on Electromagnetic Compatibility.

[14]  Jordi-Roger Riba,et al.  Comparative Study of AC and Positive and Negative DC Visual Corona for Sphere-Plane Gaps in Atmospheric Air , 2018, Energies.

[15]  J. M. K. MacAlpine,et al.  Comparison of methods for determining corona inception voltages of transmission line conductors , 2013 .

[16]  Mario Manana,et al.  Comparison between IEEE and CIGRE Thermal Behaviour Standards and Measured Temperature on a 132-kV Overhead Power Line , 2015 .

[17]  L. Babich,et al.  Generalized Paschen’s Law for Overvoltage Conditions , 2016, IEEE Transactions on Plasma Science.

[18]  B. T. Phung,et al.  Application of UHF Sensors in Power System Equipment for Partial Discharge Detection: A Review , 2019, Sensors.

[19]  L. Capineri,et al.  Partial discharge testing of solder fillets on PCBs in a partial vacuum: new experimental results , 2003 .

[20]  M. Kunicki,et al.  Radiation in the Optical and UHF Range Emitted by Partial Discharges , 2019, Energies.

[21]  Ivan J. S. Lopes,et al.  Experimental investigation of corona onset in contaminated polymer surfaces , 2015, IEEE Transactions on Dielectrics and Electrical Insulation.

[22]  D. Wotzka,et al.  Analysis of the spectrum of electromagnetic radiation generated by electrical discharges , 2019, IET Science, Measurement & Technology.

[23]  Xiang Cui,et al.  Analysis of Corona Onset Electric Field Considering the Effect of Space Charges , 2011, IEEE Transactions on Magnetics.

[24]  J. Davidson,et al.  Model of the Negative DC Corona Plasma: Comparison to the Positive DC Corona Plasma , 2003 .

[25]  G. Stone,et al.  Investigation of Corona Partial Discharge Characteristics Under Variable Frequency and Air Pressure , 2018, 2018 IEEE Electrical Insulation Conference (EIC).

[26]  E. Živanović Analysis of low-pressure DC breakdown in air , 2017, 2017 IEEE 30th International Conference on Microelectronics (MIEL).

[27]  Benjamin S. White,et al.  Ultraviolet Imaging with Low Cost Smartphone Sensors: Development and Application of a Raspberry Pi-Based UV Camera , 2016, Sensors.

[28]  Barry C. Brusso,et al.  History of Aircraft Wiring Arc-Fault Protection [History] , 2017, IEEE Industry Applications Magazine.

[29]  Xinxin Wang,et al.  Effect of distribution of electric field on low-pressure gas breakdown , 2017 .

[30]  P. Degauque,et al.  Measurement and analysis of arc tracking characteristics in the high frequency band , 2016, 2016 IEEE AUTOTESTCON.

[31]  Jinliang He,et al.  Onset conditions for positive direct current corona discharges in air under the action of photoionization , 2011 .

[32]  Alfio V Parisi,et al.  A review on the ability of smartphones to detect ultraviolet (UV) radiation and their potential to be used in UV research and for public education purposes. , 2019, The Science of the total environment.

[33]  Bian Xingming,et al.  The role of low air pressure in the variation of negative corona‐generated space charge in a rod to plane electrode , 2017, High Voltage.

[34]  J. Verboncoeur,et al.  Gas breakdown and its scaling law in microgaps with multiple concentric cathode protrusions , 2019, Applied Physics Letters.

[35]  Xingliang Jiang,et al.  Influence of air pressure and humidity on positive direct current corona discharge performances of the conductor in a corona cage , 2014 .

[36]  Ian Cotton,et al.  Impact of low pressure aerospace environment on machine winding insulation , 2010, 2010 IEEE International Symposium on Electrical Insulation.

[38]  P. Sťahel,et al.  Wide-pressure-range coplanar dielectric barrier discharge: Operational characterisation of a versatile plasma source , 2017 .

[39]  O. Lesaint,et al.  Deviations from the Paschen's law at short gap distances from 100 nm to 10 μm in air and nitrogen , 2014 .

[40]  I. Cotton,et al.  Higher voltage aircraft power systems , 2008, IEEE Aerospace and Electronic Systems Magazine.

[41]  W. Sima,et al.  Properties of Corona Discharge under Positive DC Voltage at Low Atmospheric Pressure , 2006, 2006 IEEE Conference on Electrical Insulation and Dielectric Phenomena.

[42]  Mohamed Emad Farrag,et al.  Electrical Treeing in Power Cable Insulation under Harmonics Superimposed on Unfiltered HVDC Voltages , 2019, Energies.