Shear-mediated platelet activation in patients implanted with continuous flow LVADs: A preliminary study utilizing the platelet activity state (PAS) assay

Left ventricular assist devices (LVADs) have emerged as vital life-saving therapeutic systems for patients with advanced and end-stage heart failure (HF). Despite their efficacy, VAD systems remain limited by post-implantation thrombotic complications. Shear-mediated platelet activation is the major driver of such complications in these devices. Nowadays few platelet function assays are routinely utilized in assessing the degree of platelet activation in VAD implanted patients. No assays exist that specifically target shear-mediated platelet activation. The platelet activity state (PAS) is a novel assay that has been well validated in vitro, measuring thrombin release as a surrogate for shear-mediated platelet activation. To date limited data exist as to the utility of this assay in the clinical setting. In the present study we evaluated eight LVAD patients' platelet activation level using the PAS assay. Simultaneous measurements of conventional prothrombotic and hemolysis markers, - i.e. fibrinogen and lactate dehydrogenase (LDH) - were also performed. Trends as to alteration from baseline were studied. We observed that the PAS assay allowed detection of an abnormal level of platelet activation in one patient in our series who suffered from an overt thrombosis. Interestingly in the same patient no signal of major abnormality in fibrinogen or LDH was detected. Further for 7/8 patients who were free of thrombosis, no significant level of platelet activation was detected via PAS assay, while elevation in fibrinogen and LDH were observed. As such, from our observational series it appears that the PAS assay is a sensitive and specific indicator of shear-mediated platelet activation. Further patients' experience will help elucidate the role of this promising assay in the management of LVAD implanted patients.

[1]  Shmuel Einav,et al.  Device Thrombogenicity Emulation: A Novel Method for Optimizing Mechanical Circulatory Support Device Thromboresistance , 2012, PloS one.

[2]  J Jesty,et al.  A comparison of phospholipid and platelets in the activation of human factor VIII by thrombin and factor Xa, and in the activation of factor X. , 1988, Blood.

[3]  S. Russell,et al.  Clinical management of continuous-flow left ventricular assist devices in advanced heart failure. , 2010, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[4]  M. Slaughter,et al.  Novel Thrombosis Risk Index as Predictor of Left Ventricular Assist Device Thrombosis , 2013, ASAIO journal.

[5]  J. Jesty,et al.  Activation of platelets exposed to shear stress in the presence of smoke extracts of low-nicotine and zero-nicotine cigarettes: the protective effect of nicotine. , 2004, Nicotine & tobacco research : official journal of the Society for Research on Nicotine and Tobacco.

[6]  M. Slepian,et al.  Comparative efficacy of in vitro and in vivo metabolized aspirin in the DeBakey ventricular assist device , 2014, Journal of Thrombosis and Thrombolysis.

[7]  I. Gregoric Mechanical circulatory support in acute heart failure. , 2012, Texas Heart Institute journal.

[8]  Danny Bluestein,et al.  The Extent of Platelet Activation under Shear Depends on Platelet Count: Differential Expression of Anionic Phospholipid and Factor Va , 2006, Pathophysiology of Haemostasis and Thrombosis.

[9]  J Jesty,et al.  Acetylated prothrombin as a substrate in the measurement of the procoagulant activity of platelets: elimination of the feedback activation of platelets by thrombin. , 1999, Analytical biochemistry.

[10]  G. Ewald,et al.  Unexpected abrupt increase in left ventricular assist device thrombosis. , 2014, The New England journal of medicine.

[11]  Christoph Benk,et al.  Haemolysis in patients with ventricular assist devices: major differences between systems. , 2009, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[12]  Danny Bluestein,et al.  High-Shear Stress Sensitizes Platelets to Subsequent Low-Shear Conditions , 2010, Annals of Biomedical Engineering.

[13]  Robert L Kormos,et al.  Fifth INTERMACS annual report: risk factor analysis from more than 6,000 mechanical circulatory support patients. , 2013, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[14]  J. Kirklin,et al.  Mechanical Circulatory Device Thrombosis: A New Paradigm Linking Hypercoagulation and Hypofibrinolysis , 2008, ASAIO journal.