Background There are no satisfactory, noninvasive techniques currently available to visualize the cochlear implant (CI) electrode in a dynamic state as it is advanced inside the cochlea. Objective This study describes a radiologic technique that can be used in temporal bones to monitor the electrode position in real time and to visualize the basilar membrane. Methods A cochleostomy was performed in accordance with the normal procedure for cochlear implantation in seven fresh cadaveric temporal bones. A special x-ray tube (Microfocus; Focus, Wunstorf, Germany) with a spot size of 1 &mgr;m and fluoroscopy were used for continuous videotape imaging of the advancing electrode in the cochlea. Conventional electrodes (MED-EL 40+; MED-EL, Innsbruck, Austria) and prototypes of perimodiolar electrodes (MED-EL), with varying thicknesses and angles of insertion, were used for the study. Finally, contrast liquid (Ultravist; Berlex Imaging, Schering, Germany) was injected into the scala vestibuli through the stapes footplate. Results The advancing electrode carrier was clearly visible at ×20 magnification. With the perimodiolar electrodes, deep insertion was impossible if the guiding wire was too rigid, and retraction occurred if the wire was soft. The intact nature of the basilar membrane could be confirmed by the sequential filling of scala vestibuli and the scala tympani. Conclusion To our knowledge, this is the first noninvasive study demonstrating continuous visualization with high-resolution and x-ray magnification of CI electrode advancement inside the intact cochlea. Our technique can be used for the development of CI electrodes with optimal design characteristics, especially stiffness. Visualization of the basilar membrane will influence the insertion techniques when CIs are developed for patients with residual hearing.
[1]
K. Hüttenbrink,et al.
Erste Erfahrungen mit der hochgradigen direkten Röntgenvergrößerung in der Paläontologie
,
1989
.
[2]
K. Hüttenbrink,et al.
Eine neue Röntgen-Direktvergrößerungstechnik und ihre Einsatzmöglichkeiten in der HNO
,
1986
.
[3]
S. Wilkins,et al.
Phase-contrast radiography: a new x-ray technique for cochlear implant research
,
2000
.
[4]
N. Cohen,et al.
Electrode to modiolus proximity: a fluoroscopic and histologic analysis.
,
2000,
The American journal of otology.
[5]
A. Hodges,et al.
Novel Intracochlear Electrode Positioner: Effects on Electrode Position
,
2000,
The Annals of otology, rhinology & laryngology. Supplement.
[6]
J. Fayad,et al.
The Clarion electrode positioner: temporal bone studies.
,
2000,
The American journal of otology.
[7]
G M Clark,et al.
The Contour Electrode Array: Safety Study and Initial Patient Trials of a New Perimodiolar Design
,
2001,
Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology.
[8]
W Baumgartner,et al.
Intracochlear position of cochlear implant electrodes.
,
1999,
Acta oto-laryngologica.
[9]
J. Nedzelski,et al.
Depth and quality of electrode insertion: a radiologic and pitch scaling assessment of two cochlear implant systems.
,
1999,
The American journal of otology.