Wireless and batteryless blood pressure sensor

A low-power invasive blood pressure transducer has been designed. It is based on a structure of four high resistive strain gauges in a full Wheatstone bridge configuration. For obtaining the required sensitivity, the gauge was allocated performing a careful mechanical simulation of the membrane behaviour. The electronic conditioning circuit and the ADC were optimized to compensate the noise introduced by the high resistive gauges. A batteryless RFID tag designed to incorporate and to supply the sensor was fabricated and measured. It power supplies the sensor at a distance longer than 50 cm from a standard reader, while the reported ranges —to the best of our knowledge— are shorter than 10 cm. This wireless and batteryless sensor is especially suitable for surgery rooms and intensive care units.

[1]  R. Berenguer,et al.  Design Criteria for Full Passive Long Range UHF RFID Sensor for Human Body Temperature Monitoring , 2007, 2007 IEEE International Conference on RFID.

[2]  I. Velez,et al.  Power and energy optimization of the digital core of a Gen2 long range full passive RFID sensor tag , 2008, 2008 IEEE International Conference on RFID.

[3]  Yang Xiao,et al.  Security and privacy in RFID and applications in telemedicine , 2006, IEEE Commun. Mag..

[4]  James E. Maisel Optimization of the Wheatstone Bridge Sensitivity , 1977, IEEE Transactions on Instrumentation and Measurement.

[5]  Gabor C. Temes,et al.  Circuit techniques for reducing the effects of op-amp imperfections: autozeroing, correlated double sampling, and chopper stabilization , 1996, Proc. IEEE.

[6]  Kensall D. Wise,et al.  An IC piezoresistive pressure sensor for biomedical instrumentation , 1971 .

[7]  Samuel C. Yang,et al.  Leveraging RFID in hospitals: Patient life cycle and mobility perspectives , 2007, IEEE Communications Magazine.

[8]  Jeffrey L. Hilbert RF-MEMS for Wireless Communications , 2008, IEEE Communications Magazine.

[9]  Sudipto Chakraborty,et al.  Fully Wireless Implantable Cardiovascular Pressure Monitor Integrated with a Medical Stent , 2010, IEEE Transactions on Biomedical Engineering.

[10]  J. Bryzek,et al.  Integrating microelectromechanical systems with integrated circuits , 2004, IEEE Instrumentation & Measurement Magazine.

[11]  Roc Berenguer,et al.  Full Passive UHF Tag With a Temperature Sensor Suitable for Human Body Temperature Monitoring , 2010, IEEE Transactions on Circuits and Systems II: Express Briefs.

[12]  D.J. Young,et al.  Wireless Batteryless Implantable Blood Pressure Monitoring Microsystem for Small Laboratory Animals , 2010, IEEE Sensors Journal.

[13]  Beth L. Pruitt,et al.  Review: Semiconductor Piezoresistance for Microsystems , 2009, Proceedings of the IEEE.

[14]  Robert H. Walden,et al.  Analog-to-digital converter survey and analysis , 1999, IEEE J. Sel. Areas Commun..

[15]  Agustín Leobardo Herrera-May,et al.  Electromechanical analysis of a piezoresistive pressure microsensor for low-pressure biomedical applications , 2009 .

[16]  D.J. Young,et al.  A Wireless and Batteryless 10-Bit Implantable Blood Pressure Sensing Microsystem With Adaptive RF Powering for Real-Time Laboratory Mice Monitoring , 2009, IEEE Journal of Solid-State Circuits.

[17]  Dorin Panescu,et al.  MEMS in medicine and biology. , 2006, IEEE engineering in medicine and biology magazine : the quarterly magazine of the Engineering in Medicine & Biology Society.

[18]  Walt Kester,et al.  The data conversion handbook , 2005 .