Load frequency control of power systems with non-linearities

Load frequency control (LFC) for power systems with governor deadband (GDB) and generation rate constraint (GRC) non-linearities is discussed in this study, with the objective to add anti-windup schemes for any designed LFC controller, so that the stability and performance of the existing LFC controller can be retained when there are non-linearities. Effects of GDB and GRC on the performance of LFC controllers are first analysed via describing function method. Anti-windup schemes are then proposed to compensate the GDB and GRC non-linearities. For GDB, the error between the realistic and the ideal outputs of the generator is added to the output of LFC controller for rejection, and for GRC, the error between the realistic and the ideal outputs of the turbine is fed back to the observer of the LFC controller for estimation and elimination. Simulation results show that the compensation schemes are effective in overcoming the adverse effects of GDB and GRC.

[1]  周宏,et al.  Linear active disturbance rejection control for load frequency control of power systems , 2013 .

[2]  Felix F. Wu,et al.  Describing-function analysis of automatic generation control system with governor deadband , 1978 .

[3]  Haluk Gozde,et al.  Automatic generation control application with craziness based particle swarm optimization in a thermal power system , 2011 .

[4]  J. Nanda,et al.  Transactions on Power Apparatus and Systems , Vol . PAS-1 O 0 , No . 5 , May 1981 SAMPLED-DATA AUTOMATIC GENERATION CONTROL OF INTERCONNECTED REHEAT THERMAL SYSTEMS CONSIDERING GENERATION RATE CONSTRAINTS , 2006 .

[5]  Tain-Sou Tsay Load–frequency control of interconnected power system with governor backlash nonlinearities , 2011 .

[6]  C. Concordia,et al.  Efect of Speed-Governor Dead Band on Tie-Line Power and Frequency Control Performance , 1957, Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems.

[7]  Hassan Bevrani,et al.  Application of GA optimization for automatic generation control design in an interconnected power system , 2011 .

[8]  Ali Feliachi,et al.  Robust load frequency control using genetic algorithms and linear matrix inequalities , 2003 .

[9]  C. Taylor,et al.  Automatic Generation Control Analysis With Governor Deadband Effects , 1979, IEEE Transactions on Power Apparatus and Systems.

[10]  Aysen Demiroren,et al.  Automatic Generation Control by Using ANN Technique , 2001 .

[11]  M. K. El-Sherbiny,et al.  Efficient fuzzy logic load-frequency controller , 2002 .

[12]  S. Ganapathy,et al.  Decentralized Load-Frequency Control of Interconnected Power Systems with SMES Units and Governor Dead Band using Multi-Objective Evolutionary Algorithm , 2009 .

[13]  H. Shayeghi,et al.  Load frequency control strategies: A state-of-the-art survey for the researcher , 2009 .

[14]  Ibraheem,et al.  Recent philosophies of automatic generation control strategies in power systems , 2005, IEEE Transactions on Power Systems.

[15]  Wen Tan,et al.  Unified Tuning of PID Load Frequency Controller for Power Systems via IMC , 2010, IEEE Transactions on Power Systems.

[16]  Jingqing Han,et al.  From PID to Active Disturbance Rejection Control , 2009, IEEE Trans. Ind. Electron..

[17]  Zhiqiang Gao,et al.  Scaling and bandwidth-parameterization based controller tuning , 2003, Proceedings of the 2003 American Control Conference, 2003..

[18]  Rabindra Kumar Sahu,et al.  DE optimized parallel 2-DOF PID controller for load frequency control of power system with governor dead-band nonlinearity , 2013 .

[19]  Yao Zhang,et al.  A robust decentralized load frequency controller for interconnected power systems. , 2012, ISA transactions.

[20]  S. C. Tripathy,et al.  Optimisation of load-frequency control parameters for power systems with reheat steam turbines and governor deadband nonlinearity , 1982 .