The size distribution of droplets in the exhaled breath of healthy human subjects.
暂无分享,去创建一个
Droplets carried in exhaled breath may carry microorganisms capable of transmitting disease over both short and long distances. The size distribution of such droplets will influence the type of organisms that may be carried as well as strategies for controlling airborne infection. The aim of this study was to characterize the size distribution of droplets exhaled by healthy individuals. Exhaled droplets from human subjects performing four respiratory actions (mouth breathing, nose breathing, coughing, talking) were measured by both an optical particle counter (OPC) and an analytical transmission electron microscope (AEM). The OPC indicated a preponderance of particles less than 1 mu, although larger particles were also found. Measurements with the AEM confirmed the existence of larger sized droplets in the exhaled breath. In general, coughing produced the largest droplet concentrations and nose breathing the least, although considerable intersubject variability was observed.
[1] Vernon Knight,et al. VIRUSES AS AGENTS OF AIRBORNE CONTAGION , 1980, Annals of the New York Academy of Sciences.
[2] J. F. Stampfer,et al. Particle concentration in exhaled breath. , 1987, American Industrial Hygiene Association journal.
[3] J. L. Potter,et al. HUMAN PULMONARY SECRETIONS IN HEALTH AND DISEASE , 1963, Annals of the New York Academy of Sciences.
[4] J. Duguid,et al. The size and the duration of air-carriage of respiratory droplets and droplet-nuclei , 1946, Epidemiology and Infection.