Computational modelling of bone cement polymerization: Temperature and residual stresses

The two major concerns associated with the use of bone cement are the generation of residual stresses and possible thermal necrosis of surrounding bone. An accurate modelling of these two factors could be a helpful tool to improve cemented hip designs. Therefore, a computational methodology based on previous published works is presented in this paper combining a kinetic and an energy balance equation. New assumptions are that both the elasticity modulus and the thermal expansion coefficient depend on the bone cement polymerization fraction. This model allows to estimate the thermal distribution in the cement which is later used to predict the stress-locking effect, and to also estimate the cement residual stresses. In order to validate the model, computational results are compared with experiments performed on an idealized cemented femoral implant. It will be shown that the use of the standard finite element approach cannot predict the exact temporal evolution of the temperature nor the residual stresses, underestimating and overestimating their value, respectively. However, this standard approach can estimate the peak and long-term values of temperature and residual stresses within acceptable limits of measured values. Therefore, this approach is adequate to evaluate residual stresses for the mechanical design of cemented implants. In conclusion, new numerical techniques should be proposed in order to achieve accurate simulations of the problem involved in cemented hip replacements.

[1]  N. Nuño,et al.  Modelling debonded stem-cement interface for hip implants: effect of residual stresses. , 2002, Clinical biomechanics.

[2]  M. Doblaré,et al.  A comparative FEA of the debonding process in different concepts of cemented hip implants. , 2006, Medical engineering & physics.

[3]  C. Vallo,et al.  Properties of acrylic bone cements formulated with Bis-GMA. , 2005, Journal of biomedical materials research. Part B, Applied biomaterials.

[4]  P. Prendergast,et al.  Cement mantle fatigue failure in total hip replacement: experimental and computational testing. , 2007, Journal of biomechanics.

[5]  B. van Rietbergen,et al.  Thermal analysis of bone cement polymerisation at the cement-bone interface. , 2004, Journal of biomechanics.

[6]  N. Nuño,et al.  Residual stresses at the stem-cement interface of an idealized cemented hip stem. , 2002, Journal of biomechanics.

[7]  L. Nicolais,et al.  Isothermal and non-isothermal polymerization of a new bone cement , 1998, Journal of materials science. Materials in medicine.

[8]  Claes Johnson,et al.  Finite element methods for linear hyperbolic problems , 1984 .

[9]  R Huiskes,et al.  Some fundamental aspects of human joint replacement. Analyses of stresses and heat conduction in bone-prosthesis structures. , 1980, Acta orthopaedica Scandinavica. Supplementum.

[10]  K E Tanner,et al.  Comparison between the polymerization behavior of a new bone cement and a commercial one: modeling and in vitro analysis , 1998, Journal of materials science. Materials in medicine.

[11]  C. Verdi,et al.  Numerical simulation of thermal bone necrosis during cementation of femoral prostheses , 1991, Journal of mathematical biology.

[12]  T. Hughes Multiscale phenomena: Green's functions, the Dirichlet-to-Neumann formulation, subgrid scale models, bubbles and the origins of stabilized methods , 1995 .

[13]  Jeremy L Gilbert Complexity in modeling of residual stresses and strains during polymerization of bone cement: effects of conversion, constraint, heat transfer, and viscoelastic property changes. , 2006, Journal of biomedical materials research. Part A.

[14]  A R Ingraffea,et al.  Mechanical characteristics of the stem‐cement interface , 1991, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[15]  Thomas J. R. Hughes,et al.  A space-time formulation for multiscale phenomena , 1996 .

[16]  A. T. Berman,et al.  The temperature problem at the bone-acrylic cement interface of the total hip replacement. , 1976, Clinical orthopaedics and related research.

[17]  J. Mason,et al.  Thermal characterization of PMMA-based bone cement curing , 2004, Journal of materials science. Materials in medicine.

[18]  N. Nuño,et al.  Measurement of transient and residual stresses during polymerization of bone cement for cemented hip implants. , 2008, Journal of biomechanics.

[19]  Ying Wang,et al.  The effects of curing history on residual stresses in bone cement during hip arthroplasty. , 2004, Journal of biomedical materials research. Part B, Applied biomaterials.

[20]  P. Prendergast,et al.  Residual stress due to curing can initiate damage in porous bone cement: experimental and theoretical evidence. , 2002, Journal of biomechanics.

[21]  A. M. Ahmed,et al.  Transient and residual stresses and displacements in self-curing bone cement - Part II: thermoelastic analysis of the stem fixation system. , 1982, Journal of biomechanical engineering.

[22]  M. Popa,et al.  New radiopaque acrylic bone cement. II. Acrylic bone cement with bromine-containing monomer , 2008, Journal of materials science. Materials in medicine.

[23]  V. Nassehi,et al.  Multiscale finite element modeling of diffusion-reaction equation using bubble functions with bilinear and triangular elements , 2007 .

[24]  N. Nuño,et al.  Static coefficient of friction between stainless steel and PMMA used in cemented hip and knee implants. , 2006, Clinical biomechanics.

[25]  L. Nicolais,et al.  In-situ polymerization behaviour of bone cements , 1997, Journal of materials science. Materials in medicine.

[26]  A. M. Ahmed,et al.  Thermal modeling of polymerizing polymethylmethacrylate, considering temperature-dependent heat generation. , 1992, Journal of biomechanical engineering.

[27]  S. Ferguson,et al.  Porosity reduction in bone cement at the cement-stem interface. , 1996, The Journal of bone and joint surgery. British volume.

[28]  A. McCaskie,et al.  The dynamic volume changes of polymerising polymethyl methacrylate bone cement. , 2002, Acta orthopaedica Scandinavica.

[29]  A. M. Ahmed,et al.  Transient and residual stresses and displacements in self-curing bone cement - Part I: characterization of relevant volumetric behavior of bone cement. , 1982, Journal of biomechanical engineering.

[30]  A. Taylor,et al.  Quantitative measurement of the stresses induced during polymerisation of bone cement. , 2004, Biomaterials.

[31]  G. Lewis,et al.  Properties of acrylic bone cement: state of the art review. , 1997, Journal of biomedical materials research.

[32]  C. Vallo Theoretical prediction and experimental determination of the effect of mold characteristics on temperature and monomer conversion fraction profiles during polymerization of a PMMA-based bone cement. , 2002, Journal of biomedical materials research.

[33]  R. Kusy Characterization of self-curing acrylic bone cements. , 1978, Journal of biomedical materials research.