Two mechanical devices for prophylaxis of thromboembolism after total knee arthroplasty. A prospective, randomised study.

The optimal characteristics of pneumatic compression for mechanical prophylaxis of thromboembolism after total knee arthroplasty (TKA) are not known. Our study compared two methods of calf compression, with the hypothesis that the device which provided a larger increase in peak venous velocity would produce a lower rate of thromboembolism. We performed a prospective, randomised study on 423 patients (472 knees). Duplex ultrasonography was carried out by experienced technicians who were blinded to the device used. Overall, 206 patients (232 knees) used a rapid inflation, asymmetrical compression (RIAC) device and 217 (240 knees) a sequential circumferential compression device (SCD). The rate of venous thromboembolism was 6.9% with the RIAC device compared with 15% for the SCD device (p = 0.007). The incidence of thrombi with unilateral primary TKA was 8.4% for the RIAC compared with 16.8% for the SCD device (p = 0.03). In 47 patients with a bilateral TKA, the incidence of thrombi was 4% for the RIAC compared with 22.7% for the SCD device (p = 0.05 per knee). There was a low rate of mortality and pulmonary embolism when using mechanical prophylaxis for thromboembolism after TKA. Our findings show that the use of rapid inflation, asymmetrical calf compression gave a significantly lower rate of thromboembolism.

[1]  T. Sculco,et al.  Nonpharmacologic thromboembolic prophylaxis in total knee arthroplasty. , 2001, Clinical orthopaedics and related research.

[2]  C. Colwell,et al.  Prevention of venous thromboembolism. , 1994, Chest.

[3]  S. Yeo,et al.  Deep vein thrombosis after total knee replacement. , 2000, Annals of the Academy of Medicine, Singapore.

[4]  J. Danesh,et al.  Prevention of pulmonary embolism and deep vein thrombosis with low dose aspirin: Pulmonary Embolism Prevention (PEP) trial , 2000, The Lancet.

[5]  R. Kamm,et al.  The effects of external compression on venous blood flow and tissue deformation in the lower leg. , 1999, Journal of biomechanical engineering.

[6]  J. Gaughan,et al.  Inhibition of tissue factor pathway during intermittent pneumatic compression: A possible mechanism for antithrombotic effect. , 1999, Arteriosclerosis, thrombosis, and vascular biology.

[7]  T. Sculco,et al.  Thromboembolic disease prophylaxis in total knee arthroplasty using intraoperative heparin and postoperative pneumatic foot compression. , 1999, The Journal of arthroplasty.

[8]  S. Kelley,et al.  Efficacy of prophylaxis against thromboembolism with intermittent pneumatic compression after primary and revision total hip arthroplasty. , 1999, The Journal of bone and joint surgery. American volume.

[9]  J. Lonner Thromboembolic disease in total knee arthroplasty. , 1999, The American journal of knee surgery.

[10]  G. Westrich The role of mechanical and other adjuncts. , 1999, The American journal of knee surgery.

[11]  M. Peterson,et al.  Venous haemodynamics after total knee arthroplasty: evaluation of active dorsal to plantar flexion and several mechanical compression devices. , 1998, The Journal of bone and joint surgery. British volume.

[12]  W. Maloney,et al.  Deep venous thrombosis prophylaxis for knee replacement: warfarin and pneumatic compression. , 1998, American journal of orthopedics.

[13]  E. Kruithof,et al.  Effects of intermittent pneumatic compression on venous haemodynamics and fibrinolytic activity , 1997, Blood coagulation & fibrinolysis : an international journal in haemostasis and thrombosis.

[14]  M. Steinberg,et al.  Deep Venous Thrombosis after Total Joint Arthroplasty. The Role of Compression Ultrasonography and the Importance of the Experience of the Technician* , 1996, The Journal of bone and joint surgery. American volume.

[15]  T. Sculco,et al.  Prophylaxis against Deep Venous Thrombosis after Total Knee Arthroplasty. Pneumatic Plantar Compression and Aspirin Compared with Aspirin Alone* , 1996, The Journal of bone and joint surgery. American volume.

[16]  C. Colwell,et al.  Efficacy and Safety of Enoxaparin Versus Unfractionated Heparin for Prevention of Deep Venous Thrombosis After Elective Knee Arthroplasty , 1995, Clinical orthopaedics and related research.

[17]  C. Colwell,et al.  Postoperative surveillance for deep venous thrombosis with duplex ultrasonography after total knee arthroplasty. , 1994, The Journal of bone and joint surgery. American volume.

[18]  Radcliffe Infirmary,et al.  Collaborative overview of randomised trials of antiplatelet therapy - III: Reduction in venous thrombosis and pulmonary embolism by antiplatelet prophylaxis among surgical and medical patients , 1994, BMJ.

[19]  T. Sculco,et al.  Progression and Regression of Deep Vein Thrombosis After Total Knee Arthroplasty , 1991, Clinical orthopaedics and related research.

[20]  P. Lachiewicz,et al.  Aspirin prophylaxis and surveillance of pulmonary embolism and deep vein thrombosis in total hip arthroplasty. , 1990, The Journal of arthroplasty.

[21]  G. Scuderi**,et al.  Pneumatic sequential-compression boots compared with aspirin prophylaxis of deep-vein thrombosis after total knee arthroplasty. , 1990, The Journal of bone and joint surgery. American volume.

[22]  B. Ghelman,et al.  Deep-vein thrombosis following total knee replacement. An analysis of six hundred and thirty-eight arthroplasties. , 1984, The Journal of bone and joint surgery. American volume.

[23]  P. Jaques,et al.  Doppler ultrasonic screening prior to venography for deep venous thrombosis. , 1977, AJR. American journal of roentgenology.

[24]  J. Galante,et al.  Thromboembolic disease in patients undergoing total knee replacement. , 1976, The Journal of bone and joint surgery. American volume.