Monitoring hippocampus electrical activity in vitro on an elastically deformable microelectrode array.

Interfacing electronics and recording electrophysiological activity in mechanically active biological tissues is challenging. This challenge extends to recording neural function of brain tissue in the setting of traumatic brain injury (TBI), which is caused by rapid (within hundreds of milliseconds) and large (greater than 5% strain) brain deformation. Interfacing electrodes must be biocompatible on multiple levels and should deform with the tissue to prevent additional mechanical damage. We describe an elastically stretchable microelectrode array (SMEA) that is capable of undergoing large, biaxial, 2-D stretch while remaining functional. The new SMEA consists of elastically stretchable thin metal films on a silicone membrane. It can stimulate and detect electrical activity from cultured brain tissue (hippocampal slices), before, during, and after large biaxial deformation. We have incorporated the SMEA into a well-characterized in vitro TBI research platform, which reproduces the biomechanics of TBI by stretching the SMEA and the adherent brain slice culture. Mechanical injury parameters, such as strain and strain rate, can be precisely controlled to generate specific levels of damage. The SMEA allowed for quantification of neuronal function both before and after injury, without breaking culture sterility or repositioning the electrodes for the injury event, thus enabling serial and long-term measurements. We report tests of the SMEA and an initial application to study the effect of mechanical stimuli on neuron function, which could be employed as a high-content, drug-screening platform for TBI.

[1]  Patrick A Tresco,et al.  Chronic response of adult rat brain tissue to implants anchored to the skull. , 2004, Biomaterials.

[2]  M Bove,et al.  An array of Pt-tip microelectrodes for extracellular monitoring of activity of brain slices. , 1999, Biosensors & bioelectronics.

[3]  A van Bergen,et al.  Long-term stimulation of mouse hippocampal slice culture on microelectrode array. , 2003, Brain research. Brain research protocols.

[4]  Lauren C. Frey,et al.  Epidemiology of Posttraumatic Epilepsy: A Critical Review , 2003, Epilepsia.

[5]  Makoto Taketani,et al.  Chronic multichannel recordings from organotypic hippocampal slice cultures: protection from excitotoxic effects of NMDA by non-competitive NMDA antagonists , 2002, Journal of Neuroscience Methods.

[6]  C. D. Benham,et al.  Capsazepine Protects against Neuronal Injury Caused by Oxygen Glucose Deprivation by Inhibiting Ih , 2003, The Journal of Neuroscience.

[7]  Ivan Soltesz,et al.  Long‐term hyperexcitability in the hippocampus after experimental head trauma , 2001, Annals of neurology.

[8]  L. Sundstrom,et al.  Temporal development of hippocampal cell death is dependent on tissue strain but not strain rate. , 2006, Journal of biomechanics.

[9]  R E Hampson,et al.  Ensemble Activity and Behavior—What's the Code? , 1995, Science.

[10]  Frans Spaepen,et al.  Interfaces and stresses in thin films , 2000 .

[11]  Z. Suo,et al.  Design and performance of thin metal film interconnects for skin-like electronic circuits , 2004, IEEE Electron Device Letters.

[12]  J. Povlishock,et al.  Presynaptic excitability changes following traumatic brain injury in the rat , 2000, Journal of neuroscience research.

[13]  John A Rogers,et al.  Controlled buckling of semiconductor nanoribbons for stretchable electronics , 2006, Nature nanotechnology.

[14]  K. Djupsund,et al.  Flexible polyimide microelectrode array for in vivo recordings and current source density analysis. , 2007, Biosensors & bioelectronics.

[15]  King H. Yang,et al.  Biomechanics of neurotrauma , 2001, Neurological research.

[16]  D. Kipke,et al.  Long-term neural recording characteristics of wire microelectrode arrays implanted in cerebral cortex. , 1999, Brain research. Brain research protocols.

[17]  Liang Guo,et al.  A lithographically-patterned, elastic multi-electrode array for surface stimulation of the spinal cord , 2008, Biomedical microdevices.

[18]  L. Sundstrom,et al.  Stretch‐induced injury in organotypic hippocampal slice cultures reproduces in vivo post‐traumatic neurodegeneration: role of glutamate receptors and voltage‐dependent calcium channels , 2007, Journal of neurochemistry.

[19]  M. Madou Fundamentals of microfabrication , 1997 .

[20]  Justin C. Williams,et al.  Flexible polyimide-based intracortical electrode arrays with bioactive capability , 2001, IEEE Transactions on Biomedical Engineering.

[21]  Charles W Hoge,et al.  Mild traumatic brain injury in U.S. Soldiers returning from Iraq. , 2008, The New England journal of medicine.

[22]  A. C. Greenwood,et al.  Physiological and Structural Evidence for Hippocampal Involvement in Persistent Seizure Susceptibility after Traumatic Brain Injury , 2001, The Journal of Neuroscience.

[23]  David J. Schretlen,et al.  A quantitative review of the effects of traumatic brain injury on cognitive functioning , 2003, International review of psychiatry.

[24]  G. Xiong,et al.  Mechanisms underlying the inability to induce area CA1 LTP in the mouse after traumatic brain injury , 2006, Hippocampus.

[25]  Jerald D. Kralik,et al.  Techniques for long-term multisite neuronal ensemble recordings in behaving animals. , 2001, Methods.

[26]  Yonggang Huang,et al.  Stretchable and Foldable Silicon Integrated Circuits , 2008, Science.

[27]  J. Csicsvari,et al.  Organization of cell assemblies in the hippocampus , 2003, Nature.

[28]  M. Ericson,et al.  Vertically aligned carbon nanofiber arrays record electrophysiological signals from hippocampal slices. , 2007, Nano letters.

[29]  Jose C. Principe,et al.  Evolving into epilepsy: Multiscale electrophysiological analysis and imaging in an animal model , 2006, Experimental Neurology.

[30]  W. Singer,et al.  Dynamic predictions: Oscillations and synchrony in top–down processing , 2001, Nature Reviews Neuroscience.

[31]  D. Bertrand,et al.  A three-dimensional multi-electrode array for multi-site stimulation and recording in acute brain slices , 2002, Journal of Neuroscience Methods.

[32]  D F Meaney,et al.  In vitro central nervous system models of mechanically induced trauma: a review. , 1998, Journal of neurotrauma.

[33]  Ivan Soltesz,et al.  Post-Traumatic Hyperexcitability Is Not Caused by Impaired Buffering of Extracellular Potassium , 2003, The Journal of Neuroscience.

[34]  U. Egert,et al.  A novel organotypic long-term culture of the rat hippocampus on substrate-integrated multielectrode arrays. , 1998, Brain research. Brain research protocols.

[35]  G. Doetsch,et al.  Patterns in the brain Neuronal population coding in the somatosensory system , 2000, Physiology & Behavior.

[36]  D. J. Warren,et al.  High-resolution two-dimensional spatial mapping of cat striate cortex using a 100-microelectrode array , 2001, Neuroscience.

[37]  L. Satin,et al.  Potentiation of GABA(A) currents after mechanical injury of cortical neurons. , 2004, Journal of neurotrauma.

[38]  J. Hildebrand,et al.  Multi-unit recordings reveal context-dependent modulation of synchrony in odor-specific neural ensembles , 2000, Nature Neuroscience.

[39]  T. Tamai Electrical Properties of Conductive Elastomer as Electrical Contact Material , 1982 .

[40]  W Goldsmith,et al.  Biomechanics and neuropathology of adult and paediatric head injury , 2002, British journal of neurosurgery.

[41]  Z. Suo,et al.  Stretchability of thin metal films on elastomer substrates , 2004 .

[42]  L. Sundstrom,et al.  A tissue level tolerance criterion for living brain developed with an in vitro model of traumatic mechanical loading. , 2003, Stapp car crash journal.

[43]  Michael Pecht,et al.  Fundamental reliability issues associated with a commercial particle-in-elastomer interconnection system , 2001 .

[44]  S. Margulies,et al.  Dynamic mechanical stretch of organotypic brain slice cultures induces differential genomic expression: relationship to mechanical parameters. , 2000, Journal of biomechanical engineering.

[45]  Jon A. Mukand,et al.  Neuronal ensemble control of prosthetic devices by a human with tetraplegia , 2006, Nature.

[46]  J. Povlishock,et al.  A new model for rapid stretch-induced injury of cells in culture: characterization of the model using astrocytes. , 1995, Journal of neurotrauma.

[47]  Ricardo Gattass,et al.  Electrophysiological Imaging of Functional Architecture in the Cortical Middle Temporal Visual Area of Cebus apella Monkey , 2003, The Journal of Neuroscience.

[48]  Z. Suo,et al.  Stretchable gold conductors on elastomeric substrates , 2003 .

[49]  D. W. Pashley A study of the deformation and fracture of single-crystal gold films of high strength inside an electron microscope , 1960, Proceedings of the Royal Society of London. Series A. Mathematical and Physical Sciences.

[50]  U. Egert,et al.  A thin film microelectrode array for monitoring extracellular neuronal activity in vitro. , 1994, Biosensors & bioelectronics.

[51]  J. Taube,et al.  Mechanisms of long-term potentiation: a current-source density analysis , 1988, The Journal of neuroscience : the official journal of the Society for Neuroscience.

[52]  L. Sundstrom,et al.  An in vitro model of traumatic brain injury utilising two-dimensional stretch of organotypic hippocampal slice cultures , 2006, Journal of Neuroscience Methods.

[53]  B. Morrison,et al.  Region-specific tolerance criteria for the living brain. , 2007, Stapp car crash journal.

[54]  John M. Beggs,et al.  Neuronal Avalanches in Neocortical Circuits , 2003, The Journal of Neuroscience.

[55]  P. Ho,et al.  FRACTURE OF METAL-POLYMER LINE STRUCTURES. I: SEMIFLEXIBLE POLYIMIDE , 1994 .

[56]  G. Buzsáki Large-scale recording of neuronal ensembles , 2004, Nature Neuroscience.