Critique of "ISO TS 13571 - 2002 - Life-threatening components of fire — Guidelines for the estimation of time available for escape using fire data"

API has released a document which provides a critique of ISO Technical Specification (TS) 13571-Life Threatening Components of Fire-Guidelines for the Estimation of Time Available for Escape Using Fire Data. The critique is timely because this " lower level " ISO Technical Specification will soon be balloted to become a full ISO Standard. In addition, there is an effort to adopt the document as an ASTM standard which would have larger implications for plastics in the U.S. The detailed critique, prepared by Dr. Marcelo Hirschler of GBH International, reviews different aspects of the document as it discusses how to assess the time available for escape from a fire and compare it with the time required for escape based on the generation of fire gases. The document has positive points regarding this concept; however, its treatment of incapacitating gases, such as HCl, from a fire is flawed. The ISO document could be used to develop limits on the use of plastics, including polyurethanes. Besides the common use of chlorine or bromine containing flame retardants in urethanes, there may be other irritant fire gases that could be identified and put into the equation to even further restrict the use of polyurethanes and other plastics. Possible limitations on polyurethanes could involve both rigid foam used as insulation or flexible foam in furnishings. This critique discusses the details of ISO TS 13571, the scientific basis of its concepts, its practical implications and flaws found in the rationale used to develop 13571.

[1]  Barbara C. Levin,et al.  Fire Hazard Comparison of Fire-Retarded and Non-Fire-Retarded Products , 1988 .

[2]  J. Amoore,et al.  Odor as an ald to chemical safety: Odor thresholds compared with threshold limit values and volatilities for 214 industrial chemicals in air and water dilution , 1983, Journal of applied toxicology : JAT.

[3]  S. C. Packham,et al.  Modeling of Toxicological Effects of Fire Gases: Iv. Intoxication of Rats By Carbon Monoxide in the Presence of an Irritant , 1985 .

[4]  E Braun,et al.  Role of Bench-Scale Test Data in Assessing Real-Scale Fire Toxicity (NIST TN 1284) , 1991 .

[5]  Mm Hirschler,et al.  The Toxicity of Hydrogen Chloride and of the Smoke Generated by Poly (Vinyl Chloride), Including Effects on Various Animal Species, and the Implications for Fire Safety , 1990 .

[6]  Arthur F. Grand,et al.  Modeling of Toxicological Effects of Fire Gases: VI. Further Studies on the Toxicity of Smoke Containing Hydrogen Chloride , 1987 .

[7]  Louise C. Speitel,et al.  Toxicity Assessment of Combustion Gases and Development of a Survival Model. , 1995 .

[8]  R. Peacock,et al.  Technical references guide for the HAZARD I fire hazard assessment method , 1989 .

[9]  L C Speitel Fractional effective dose model for post-crash aircraft survivability. , 1996, Toxicology.

[10]  Marcelo M. Hirschler,et al.  Irritancy of the smoke (non‐flaming mode) from materials used for coating wire and cable products, both in the presence and absence of halogens in their chemical composition , 1993 .

[11]  Tadahisa Jin,et al.  Visibility through fire smoke , 1978 .

[12]  T. Jin,et al.  Studies of Emotional Instability in Smoke from Fires , 1981 .

[13]  Arthur F. Grand,et al.  Effects of Combustion Gases On Escape Performance of the Baboon and the Rat , 1985 .