Characterization of a hybrid diffuse correlation spectroscopy and time-resolved near-infrared spectroscopy system for real-time monitoring of cerebral blood flow and oxygenation

The combination of near-infrared spectroscopy (NIRS) and diffuse correlation spectroscopy (DCS) offers the ability to provide real-time monitoring of cerebral oxygenation, blood flow and oxygen consumption. However, measuring these parameters accurately requires depth-sensitive techniques that can remove the effects of signal contamination from extracerebral tissues. Towards this goal, we developed and characterized a hybrid DCS/time-resolved (TR)-NIRS system. Both systems acquire data at three source-detector distances (SDD: 7, 20 and 30 mm) to provide depth sensitivity. The TR-NIRS system uses three pulsed lasers (760, 810, and 830 nm) to quantify tissue optical properties, and DCS uses one continuous-wave, long coherence length (>5 m) laser (785 nm) for blood flow monitoring. The stability of the TR-NIRS system was characterized by continuously measuring the instrument response function (IRF) for four hours, and a warmup period of two hours was required to reduce the coefficient of variation of the extracted optical properties to < 2%. The errors in the measured optical properties were <10% at SDDs of 20 and 30 mm; however, the error at 7 mm was greater due to the effects of the IRF. The number of DCS detectors at each SDD and the minimum count-rate (20 kHz per detector resulting in <10% uncertainty in the extracted blood flow index) were optimized using a homogenous phantom. The depth sensitivity was assessed using a two-layer phantom, with the flow rate in the bottom layer altered to mimic cerebral blood flow.

[1]  Ting-Yim Lee,et al.  Comparison of time-resolved and continuous-wave near-infrared techniques for measuring cerebral blood flow in piglets. , 2010, Journal of biomedical optics.

[2]  Britton Chance,et al.  Accuracy limits in the determination of absolute optical properties using time-resolved NIR spectroscopy. , 2001 .

[3]  Ting-Yim Lee,et al.  Calibration of diffuse correlation spectroscopy with a time-resolved near-infrared technique to yield absolute cerebral blood flow measurements: errata , 2012, Biomedical optics express.

[4]  David A Boas,et al.  Sensitivity of near-infrared spectroscopy and diffuse correlation spectroscopy to brain hemodynamics: simulations and experimental findings during hypercapnia , 2014, Neurophotonics.

[5]  G. Maret,et al.  Diffusing-wave spectroscopy from head-like tissue phantoms: influence of a non-scattering layer. , 2006, Optics express.

[6]  D. Boas,et al.  Spatially varying dynamical properties of turbid media probed with diffusing temporal light correlation , 1997 .

[7]  D. Boas,et al.  Double-layer estimation of intra- and extracerebral hemoglobin concentration with a time-resolved system. , 2008, Journal of biomedical optics.

[8]  Louis Gagnon,et al.  Investigation of diffuse correlation spectroscopy in multi-layered media including the human head. , 2008, Optics express.

[9]  M. Diop,et al.  Improving the depth sensitivity of time-resolved measurements by extracting the distribution of times-of-flight , 2013, Biomedical optics express.

[10]  Laura B. Morrison,et al.  Quantifying cerebral blood flow in an adult pig ischemia model by a depth-resolved dynamic contrast-enhanced optical method , 2014, NeuroImage.

[11]  A. Yodh,et al.  In vivo cerebrovascular measurement combining diffuse near-infrared absorption and correlation spectroscopies. , 2001, Physics in medicine and biology.

[12]  J. Detre,et al.  Diffuse optical measurement of blood flow, blood oxygenation, and metabolism in a human brain during sensorimotor cortex activation. , 2004, Optics letters.

[13]  Kenneth M. Tichauer,et al.  Time-resolved near-infrared technique for bedside monitoring of absolute cerebral blood flow , 2010, BiOS.

[14]  Mamadou Diop,et al.  Quantifying the cerebral metabolic rate of oxygen by combining diffuse correlation spectroscopy and time-resolved near-infrared spectroscopy , 2013, Journal of biomedical optics.

[15]  Kijoon Lee,et al.  Diffuse correlation spectroscopy with a fast Fourier transform-based software autocorrelator , 2012, Journal of biomedical optics.

[16]  G. Dietsche,et al.  Fiber-based multispeckle detection for time-resolved diffusing-wave spectroscopy: characterization and application to blood flow detection in deep tissue. , 2007, Applied optics.

[17]  M. Patterson,et al.  Improved solutions of the steady-state and the time-resolved diffusion equations for reflectance from a semi-infinite turbid medium. , 1997, Journal of the Optical Society of America. A, Optics, image science, and vision.

[18]  A. Villringer,et al.  Time-resolved multidistance near-infrared spectroscopy of the adult head: intracerebral and extracerebral absorption changes from moments of distribution of times of flight of photons. , 2004, Applied optics.

[19]  A. Villringer,et al.  Determining changes in NIR absorption using a layered model of the human head , 2001, Physics in medicine and biology.