Estimating metabolic equivalents for activities in daily life using acceleration and heart rate in wearable devices

BackgroundHerein, an algorithm that can be used in wearable health monitoring devices to estimate metabolic equivalents (METs) based on physical activity intensity data, particularly for certain activities in daily life that make MET estimation difficult.ResultsEnergy expenditure data were obtained from 42 volunteers using indirect calorimetry, triaxial accelerations and heart rates. The proposed algorithm used the percentage of heart rate reserve (%HRR) and the acceleration signal from the wearable device to divide the data into a middle-intensity group and a high-intensity group (HIG). The two groups were defined in terms of estimated METs. Evaluation results revealed that the classification accuracy for both groups was higher than 91%. To further facilitate MET estimation, five multiple-regression models using different features were evaluated via leave-one-out cross-validation. Using this approach, all models showed significant improvements in mean absolute percentage error (MAPE) of METs in the HIG, which included stair ascent, and the maximum reduction in MAPE for HIG was 24% compared to the previous model (HJA-750), which demonstrated a 70.7% improvement ratio. The most suitable model for our purpose that utilized heart rate and filtered synthetic acceleration was selected and its estimation error trend was confirmed.ConclusionFor HIG, the MAPE recalculated by the most suitable model was 10.5%. The improvement ratio was 71.6% as compared to the previous model (HJA-750C). This result was almost identical to that obtained from leave-one-out cross-validation. This proposed algorithm revealed an improvement in estimation accuracy for activities in daily life; in particular, the results included estimated values associated with stair ascent, which has been a difficult activity to evaluate so far.

[1]  Ronald M. Summers,et al.  Predicting Polyp Location on Optical Colonoscopy From CT Colonography by Minimal-Energy Curve Modeling of the Colonoscope Path , 2012, IEEE Transactions on Biomedical Engineering.

[2]  Yong Lian,et al.  A 300-mV 220-nW Event-Driven ADC With Real-Time QRS Detection for Wearable ECG Sensors , 2014, IEEE Transactions on Biomedical Circuits and Systems.

[3]  Y. Oshima,et al.  Classifying household and locomotive activities using a triaxial accelerometer. , 2010, Gait & posture.

[4]  Basabi Bhaumik,et al.  An ultra low power ECG signal processor design for cardiovascular disease detection , 2015, 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[5]  Mitja Lustrek,et al.  Energy expenditure estimation with wearable accelerometers , 2012, 2012 IEEE International Symposium on Circuits and Systems.

[6]  Y. Oshima,et al.  Real-time estimation of daily physical activity intensity by a triaxial accelerometer and a gravity-removal classification algorithm. , 2011, The British journal of nutrition.

[7]  E. Bocchi,et al.  The Relationship Between Heart Rate Reserve and Oxygen Uptake Reserve in Heart Failure Patients on Optimized and Non-Optimized Beta-Blocker Therapy , 2008, Clinics.

[8]  D. Bassett,et al.  Accuracy of the Actiheart for the assessment of energy expenditure in adults , 2008, European Journal of Clinical Nutrition.

[9]  Matjaz Gams,et al.  Context-based ensemble method for human energy expenditure estimation , 2015, Appl. Soft Comput..

[10]  Jeen-Shing Wang,et al.  A Wearable Sensor Module With a Neural-Network-Based Activity Classification Algorithm for Daily Energy Expenditure Estimation , 2012, IEEE Transactions on Information Technology in Biomedicine.

[11]  S. Blair,et al.  A comparative evaluation of three accelerometry-based physical activity monitors. , 2000, Medicine and science in sports and exercise.

[12]  Shintaro Izumi,et al.  Physical activity group classification algorithm using triaxial acceleration and heart rate , 2015, 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[13]  P. Deurenberg,et al.  A critical evaluation of heart rate monitoring to assess energy expenditure in individuals. , 1993, The American journal of clinical nutrition.

[14]  Mitja Lustrek,et al.  Estimating Energy Expenditure With Multiple Models Using Different Wearable Sensors , 2016, IEEE Journal of Biomedical and Health Informatics.

[15]  Charles E Matthew,et al.  Calibration of accelerometer output for adults. , 2005, Medicine and science in sports and exercise.

[16]  Robert X. Gao,et al.  Multisensor Data Fusion for Physical Activity Assessment , 2012, IEEE Transactions on Biomedical Engineering.

[17]  D A Boone,et al.  Step activity monitor: long-term, continuous recording of ambulatory function. , 1999, Journal of rehabilitation research and development.

[18]  Ning Wang,et al.  Energy expenditure estimation during normal ambulation using triaxial accelerometry and barometric pressure , 2012, Physiological measurement.

[19]  Kazunobu Okazaki,et al.  A new device to estimate VO2 during incline walking by accelerometry and barometry. , 2009, Medicine and science in sports and exercise.

[20]  David Minnen,et al.  Recognizing Soldier Activities in the Field , 2007, BSN.

[21]  Tae-Seong Kim,et al.  A Triaxial Accelerometer-Based Physical-Activity Recognition via Augmented-Signal Features and a Hierarchical Recognizer , 2010, IEEE Transactions on Information Technology in Biomedicine.

[22]  J. B. Weir New methods for calculating metabolic rate with special reference to protein metabolism , 1949, The Journal of physiology.

[23]  B E Ainsworth,et al.  Validity of four motion sensors in measuring moderate intensity physical activity. , 2000, Medicine and science in sports and exercise.

[24]  Mathieu Lemay,et al.  Physical activity profiling: Activity-specific step counting and energy expenditure models using 3D wrist acceleration , 2015, 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[25]  A M Nevill,et al.  Training Induced Changes in Maximum Heart Rate , 2007, International journal of sports medicine.

[26]  Ravi Narasimhan,et al.  Wireless patch sensor for remote monitoring of heart rate, respiration, activity, and falls , 2013, 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[27]  Sergio Cerutti,et al.  Energy expenditure estimation using triaxial accelerometry and barometric pressure measurement , 2010, 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology.

[28]  Jeff A. Bilmes,et al.  Rao-Blackwellized Particle Filters for Recognizing Activities and Spatial Context from Wearable Sensors , 2006, ISER.

[29]  Scott E Crouter,et al.  A novel method for using accelerometer data to predict energy expenditure. , 2006, Journal of applied physiology.

[30]  Hiroshi Nakajima,et al.  Normally Off ECG SoC With Non-Volatile MCU and Noise Tolerant Heartbeat Detector , 2015, IEEE Transactions on Biomedical Circuits and Systems.

[31]  Hikaru Inooka,et al.  Automatic classification of ambulatory movements and evaluation of energy consumptions utilizing accelerometers and a barometer , 2005 .

[32]  Katie Gant,et al.  Long-term recording of electromyographic activity from multiple muscles to monitor physical activity of participants with or without a neurological disorder , 2017, Biomedizinische Technik. Biomedical engineering.