A mathematical model on adjacent smoke filling involved sprinkler cooling to a smoke layer

Conventional two-zone model determines the smoke filling time in buildings without considering the cooling effect of sprinkler spray on the smoke layer. However, many buildings have been required to install the sprinkler systems by fire codes. So, the conventional zone model was not able to accurately predict the development of smoke layer height in a sprinklers involved fire. In order to improve the prediction, the current zone model is revised with a new mathematical model developed by taking the sprinkler cooling effect into account. The heat transfer between smoke layer and sprinklers spray was mathematically calculated. By using the mathematical model, the smoke filling time in an adjacent space under the sprinkler cooling effect are calculated. A set of experiments were carried out to validate the model. The smoke layer height was experimentally measured. Results show that the model predictions agree well with the experimental results. The smoke filling becomes slower due to the reduced volumetric smoke flow under sprinkler cooling. The variation of sprinkler operating pressure has little influence on the smoke filling since the cooling gets less effective as the operating pressure increases.

[1]  H. P. Morgan HEAT TRANSFER FROM A BUOYANT SMOKE LAYER BENEATH A CEILING TO A SPRINKLER SPRAY: A TENTATIVE THEORY , 1977 .

[2]  G. O. Hansell,et al.  Atrium buildings: Calculating smoke flows in atria for smoke-control , 1987 .

[3]  Kaiyuan Li,et al.  Experimental investigation on drag effect of sprinkler spray to adjacent horizontal natural smoke venting. , 2010, Journal of hazardous materials.

[4]  Dong Yang,et al.  A Mathematical Model for Cooling Effect of Sprinkler on Smoke Layer , 2009 .

[5]  Takeyoshi Tanaka,et al.  Smoke Control in Large Scale Spaces , 1985 .

[6]  Wan Ki Chow,et al.  Experimental Studies on Sprinkler Water Spray—Smoke Layer Interaction , 1994 .

[7]  H. P. Morgan,et al.  Heat transfer from a buoyant smoke layer beneath a ceiling to a sprinkler spray. 2—an experiment , 1979 .

[8]  Takashi Kashiwagi,et al.  Fire safety science : proceedings of the Fourth international symposium , 1994 .

[9]  Kaiyuan Li,et al.  A Mathematical Model on Interaction of Smoke Layer with Sprinkler Spray , 2009 .

[10]  Kee-Chiang Chung,et al.  A Simplified Model for Smoke Filling Time Calculation with Sprinkler Effects , 2005 .

[11]  Toshio Yamana,et al.  Smoke control in large scale spaces. Part 1: Analytic theories for simple smoke control problems.:(Part 1 : Analytic Theories For Simple Smoke Control Problems) , 1985 .

[12]  D. J. Rasbash,et al.  Mechanisms of extinction of liquid fires with water sprays , 1960 .

[13]  Frederick W. Mowrer,et al.  Enclosure smoke filling revisited , 1999 .

[14]  Wan Ki Chow On the use of time constants for specifying the smoke filling process in atrium halls , 1997 .

[15]  J. L. Lee,et al.  Suppression Of Rack-storage Fires By Water , 1994 .