Dissipative Roof Diaphragm for the Seismic Retrofit of Listed Masonry Churches

ABSTRACT In the seismic retrofit of the existing masonry buildings, dissipative and deformable roof diaphragms could offer an efficient solution in cases where both the adoption of steel ties or stiff diaphragms would be ineffective. An innovative deformable, dissipative and lightweight roof diaphragm for the seismic retrofit of masonry churches is proposed. Such a diaphragm prevents the overturning of the side walls whilst allowing the onset of a controlled rocking mechanism. The specific diaphragm elasto-plastic response caps the seismic actions transferred by the roof diaphragm to the seismic resistant walls, in contrast to a rigid and a stiffened diaphragm. This effect is meant to mitigate the overload of the head walls, thus preventing their collapse or the need for their strengthening, which could require interventions invasive of the historical structure. The feasibility of the proposed retrofit strategy is assessed through the experimental characterization of a prototype diaphragm sub-assembly and non-linear dynamic analyses of the global response of two retrofitted reference buildings.

[1]  Can Celalettin Simsir,et al.  Influence of Diaphragm Flexibility on the Out -of -Plane Dynamic Response of Unreinforced Masonry Walls , 2004 .

[2]  Alberto Meda,et al.  RC structural wall with unbonded tendons strengthened with high-performance fiber-reinforced concrete , 2015 .

[3]  Ezio Giuriani,et al.  Experimental response of a large scale transverse-arch subjected to horizontal cyclic loading , 2013 .

[4]  Andre Filiatrault,et al.  Distributed Yielding Concept for Improved Seismic Collapse Performance of Rigid Wall-Flexible Diaphragm Buildings , 2016 .

[5]  Stephen Pessiki,et al.  Seismic behavior and design of unbonded post-tensioned precast concrete frames , 1999 .

[6]  Ezio Giuriani,et al.  Coperture scatolari antisismiche , 2011 .

[7]  Gianmarco De Felice,et al.  Out‐of‐plane seismic behaviour of rocking masonry walls , 2012 .

[8]  Giuseppe Brandonisio,et al.  Closed form solution for predicting the horizontal capacity of masonry portal frames through limit analysis and comparison with experimental test results , 2015 .

[9]  Kenneth J. Elwood,et al.  Out-of-Plane Dynamic Stability of Unreinforced Masonry Walls in One-Way Bending: Shake Table Testing , 2016 .

[10]  Ezio Giuriani,et al.  Thin-folded Shell for the Renewal of Existing Wooden Roofs , 2016 .

[11]  C. Arya Eurocode 6: Design of masonry structures , 2009 .

[12]  G. Housner The behavior of inverted pendulum structures during earthquakes , 1963 .

[13]  Ezio Giuriani,et al.  EXAMPLE OF THE BENEFITS OF A DISSIPATIVE ROOF DIAPHRAGM IN THE SEISMIC RESPONSE OF MASONRY BUILDINGS , 2014 .

[14]  C. Şimşir,et al.  OUT-OF-PLANE DYNAMIC RESPONSE OF UNREINFORCED MASONRY BEARING WALLS ATTACHED TO FLEXIBLE DIAPHRAGMS , 2002 .

[15]  A. Mandara,et al.  Energy dissipation devices in seismic upgrading of monumental buildings , 2003 .

[16]  José I. Restrepo,et al.  Seismic performance of self-centering structural walls incorporating energy dissipators , 2007 .

[17]  Maurizio Indirli,et al.  Shape Memory Alloy Devices for the Structural Improvement of Masonry Heritage Structures , 2008 .

[18]  Ezio Giuriani,et al.  Seismic Vulnerability for Churches in Association with Transverse Arch Rocking , 2009 .

[19]  Guido Magenes,et al.  Shaking Table Test of a Strengthened Full-Scale Stone Masonry Building with Flexible Diaphragms , 2014 .

[20]  Dina D'Ayala,et al.  Development and testing of dissipative anchor devices for the seismic protection of heritage buildings , 2009 .

[21]  Polona Weiss,et al.  Seismic Upgrading of Old Brick-Masonry Urban Houses: Tying of Walls with Steel Ties , 1996 .

[22]  Sri Sritharan,et al.  Preliminary results and conclusions from the PRESSS five-story precast concrete test Building , 1999 .

[23]  Ezio Giuriani,et al.  Lightweight extrados restraining elements for the anti-seismic retrofit of single leaf vaults , 2017 .

[24]  E. Giuriani,et al.  Experiences from the Northern Italy 2004 earthquake: vulnerability assessment and strengthening of historic churches , 2010 .

[25]  Elena Mele,et al.  A simplified procedure for assessing the seismic capacity of masonry arches , 2004 .

[26]  Ezio Giuriani,et al.  Wooden Roof Box Structure for the Anti-Seismic Strengthening of Historic Buildings , 2008 .

[27]  G. Magenes,et al.  EVALUATION OF OUT-OF-PLANE STABILITY OF UNREINFORCED MASONRY WALLS SUBJECTED TO SEISMIC EXCITATION , 2003 .

[28]  Michael C. Griffith,et al.  Influence of Diaphragm Flexibility on Seismic Response of Unreinforced Masonry Buildings , 2017 .