Adaptive model-predictive controller for magnetic resonance guided focused ultrasound therapy

Abstract Purpose: Minimising treatment time and protecting healthy tissues are conflicting goals that play major roles in making magnetic resonance image-guided focused ultrasound (MRgFUS) therapies clinically practical. We have developed and tested in vivo an adaptive model-predictive controller (AMPC) that reduces treatment time, ensures safety and efficacy, and provides flexibility in treatment set-up. Materials and methods: The controller realises time savings by modelling the heated treatment cell’s future temperatures and thermal dose accumulation in order to anticipate the optimal time to switch to the next cell. Selected tissues are safeguarded by a configurable temperature constraint. Simulations quantified the time savings realised by each controller feature as well as the trade-offs between competing safety and treatment time parameters. In vivo experiments in rabbit thighs established the controller’s effectiveness and reliability. Results: In all in vivo experiments the target thermal dose of at least 240 CEM43 was delivered everywhere in the treatment volume. The controller’s temperature safety limit reliably activated and constrained all protected tissues to <9 CEM43. Simulations demonstrated the path independence of the controller, and that a path which successively proceeds to the hottest untreated neighbouring cell leads to significant time savings, e.g. when compared to a concentric spiral path. Use of the AMPC produced a compounding time-saving effect; reducing the treatment cells’ heating times concurrently reduced heating of normal tissues, which eliminated cooling periods. Conclusions: Adaptive model-predictive control can automatically deliver safe, effective MRgFUS treatments while significantly reducing treatment times.

[1]  P. J. Hoopes,et al.  Basic principles of thermal dosimetry and thermal thresholds for tissue damage from hyperthermia , 2003, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[2]  Jean-François Geschwind,et al.  MRI guidance of focused ultrasound therapy of uterine fibroids: early results. , 2004, AJR. American journal of roentgenology.

[3]  K Hynynen,et al.  Temperature elevation at muscle-bone interface during scanned, focused ultrasound hyperthermia. , 1988, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[4]  G. Ehnholm,et al.  Volumetric HIFU ablation under 3D guidance of rapid MRI thermometry. , 2009, Medical physics.

[5]  K Hynynen,et al.  Focal spacing and near-field heating during pulsed high temperature ultrasound therapy. , 1993, Ultrasound in medicine & biology.

[6]  Urvi Vyas,et al.  Minimisation of HIFU pulse heating and interpulse cooling times , 2010, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[7]  Nick Todd,et al.  The effect of electronically steering a phased array ultrasound transducer on near-field tissue heating. , 2011, Medical physics.

[8]  W. Dewey,et al.  Thermal dose determination in cancer therapy. , 1984, International journal of radiation oncology, biology, physics.

[9]  H. H. Pennes Analysis of tissue and arterial blood temperatures in the resting human forearm. , 1948, Journal of applied physiology.

[10]  Chris J Diederich,et al.  Transurethral ultrasound applicators with dynamic multi-sector control for prostate thermal therapy: in vivo evaluation under MR guidance. , 2008, Medical physics.

[11]  F A Jolesz,et al.  MR imaging-guided focused ultrasound surgery of fibroadenomas in the breast: a feasibility study. , 2001, Radiology.

[12]  Nick Todd,et al.  The effects of spatial sampling choices on MR temperature measurements , 2011, Magnetic resonance in medicine.

[13]  K. Hynynen,et al.  Transcranial Magnetic Resonance Imaging– Guided Focused Ultrasound Surgery of Brain Tumors: Initial Findings in 3 Patients , 2010, Neurosurgery.

[14]  C. Diederich,et al.  Axial control of thermal coagulation using a multi-element interstitial ultrasound applicator with internal cooling , 2000, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[15]  Matthias David,et al.  Focused ultrasound treatment of uterine fibroid tumors: safety and feasibility of a noninvasive thermoablative technique. , 2003, American journal of obstetrics and gynecology.

[16]  Guy Vallancien,et al.  High-intensity focused ultrasound and localized prostate cancer: efficacy results from the European multicentric study. , 2003, Journal of endourology.

[17]  Aki Pulkkinen,et al.  The utility of sparse 2D fully electronically steerable focused ultrasound phased arrays for thermal surgery: a simulation study , 2011, Physics in medicine and biology.

[18]  P. VanBaren,et al.  Multipoint temperature control during hyperthermia treatments: theory and simulation , 1995, IEEE Transactions on Biomedical Engineering.

[19]  Rares Salomir,et al.  Automatic spatial and temporal temperature control for MR‐guided focused ultrasound using fast 3D MR thermometry and multispiral trajectory of the focal point , 2004, Magnetic resonance in medicine.

[20]  F A Jolesz,et al.  Usefulness of MR imaging-derived thermometry and dosimetry in determining the threshold for tissue damage induced by thermal surgery in rabbits. , 2000, Radiology.

[21]  W. Gedroyc,et al.  New Clinical Applications of Magnetic Resonance-Guided Focused Ultrasound , 2006, Topics in magnetic resonance imaging : TMRI.

[22]  J A de Zwart,et al.  Local hyperthermia with MR‐guided focused ultrasound: Spiral trajectory of the focal point optimized for temperature uniformity in the target region , 2000, Journal of magnetic resonance imaging : JMRI.

[23]  Jeong-Won Lee,et al.  A faster nonsurgical solution very large fibroid tumors yielded to a new ablation strategy. , 2011, American journal of obstetrics and gynecology.

[24]  K Hynynen,et al.  The effect of various physical parameters on the size and shape of necrosed tissue volume during ultrasound surgery. , 1994, The Journal of the Acoustical Society of America.

[25]  Bruno Quesson,et al.  Improved Volumetric MR-HIFU Ablation by Robust Binary Feedback Control , 2010, IEEE Transactions on Biomedical Engineering.

[26]  K Hynynen,et al.  Control system for an MRI compatible intracavitary ultrasound array for thermal treatment of prostate disease. , 2001, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[27]  M. A. van den Bosch,et al.  MR-Guided High-Intensity Focused Ultrasound Ablation of Breast Cancer with a Dedicated Breast Platform , 2013, CardioVascular and Interventional Radiology.

[28]  Nick Todd,et al.  Reconstruction of fully three‐dimensional high spatial and temporal resolution MR temperature maps for retrospective applications , 2012, Magnetic resonance in medicine.

[29]  K Hynynen,et al.  The feasibility of MRI feedback control for intracavitary phased array hyperthermia treatments. , 1998, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[30]  Nick Todd,et al.  HIFU treatment time reduction through heating approach optimisation , 2012, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[31]  F A Jolesz,et al.  Determination of the optimal delay between sonications during focused ultrasound surgery in rabbits by using MR imaging to monitor thermal buildup in vivo. , 1999, Radiology.

[32]  Kullervo Hynynen,et al.  MRI evaluation of thermal ablation of tumors with focused ultrasound , 1998, Journal of magnetic resonance imaging : JMRI.

[33]  F A Jolesz,et al.  Thermal dosimetry of a focused ultrasound beam in vivo by magnetic resonance imaging. , 1999, Medical physics.

[34]  Jeffery H. Wootton,et al.  Catheter-based ultrasound devices and MR thermal monitoring for conformal prostate thermal therapy , 2008, 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[35]  Max Wintermark,et al.  A pilot study of focused ultrasound thalamotomy for essential tremor. , 2013, The New England journal of medicine.

[36]  Takamichi Murakami,et al.  A case of hepatocellular carcinoma treated by MR-guided focused ultrasound ablation with respiratory gating. , 2006, Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine.

[37]  D. Christensen,et al.  Ultrasound beam simulations in inhomogeneous tissue geometries using the hybrid angular spectrum method , 2012, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[38]  Rares Salomir,et al.  Feasibility of MR‐guided focused ultrasound with real‐time temperature mapping and continuous sonication for ablation of VX2 carcinoma in rabbit thigh , 2003, Magnetic resonance in medicine.

[39]  Sharon Thomsen,et al.  Magnetic resonance-guided focused ultrasound surgery of breast cancer: reliability and effectiveness. , 2006, Journal of the American College of Surgeons.

[40]  Jaya Prakash,et al.  Toward real‐time availability of 3D temperature maps created with temporally constrained reconstruction , 2014, Magnetic resonance in medicine.

[41]  K Hynynen,et al.  Ultrasound surgery using multiple sonications--treatment time considerations. , 1996, Ultrasound in medicine & biology.

[42]  F. Fry,et al.  Transkull transmission of an intense focused ultrasonic beam. , 1977, Ultrasound in medicine & biology.

[43]  Dhiraj Arora,et al.  Control of thermal therapies with moving power deposition field. , 2006, Physics in medicine and biology.

[44]  Bruno Quesson,et al.  Volumetric HIFU ablation under 3D guidance of rapid MRI thermometry. , 2009, Medical physics.

[45]  Santosh Devasia,et al.  Exact temperature tracking for hyperthermia: a model-based approach , 2000, IEEE Trans. Control. Syst. Technol..

[46]  Francis A. Duck,et al.  Physical properties of tissue : a comprehensive reference book , 1990 .