Performance analysis of a modified zeotropic mixture (R290/R600) refrigeration cycle with internal subcooler for freezer applications

Abstract This study presents a modified vapor compression refrigeration cycle (MVRC) using zeotropic mixture R290/R600 for freezers. In the MVRC, an internal subcooler with additional bypass tube is introduced to enhance the overall system performance. Energetic and exergetic analysis methods are introduced to theoretically evaluate the system operating performance, and compared with the performance of the traditional vapor compression refrigeration cycle (TVRC). The results show that the MVRC yields higher refrigeration coefficient of performance (COP), volumetric cooling capacity and exergy efficiency than the TVRC. Under the given condition, the COP, volumetric cooling capacity and exergy efficiency of MVRC could be improved by up to an average of 8.9%, 12.4% and 10.4%. Moreover, COP and exergy efficiency of MVRC increases with the rising bypass coefficient of the refrigerant. The performance characteristics of the proposed novel cycle demonstrate the potential advantages for application in freezer systems.

[1]  B. Palm Hydrocarbons as refrigerants in small heat pump and refrigeration systems – A review , 2008 .

[2]  Mehmet Yilmaz,et al.  Performance analysis of a vapor compression heat pump using zeotropic refrigerant mixtures , 2003 .

[3]  S. Klein,et al.  NIST Standard Reference Database 23: NIST Thermodynamic and Transport Properties of Refrigerants and Refrigerant Mixtures-REFPROP, Version 6.0 | NIST , 1998 .

[4]  H. Kursad Ersoy,et al.  Performance improvement of the vapour compression refrigeration cycle by a two‐phase constant area ejector , 2009 .

[5]  S. Jayaraj,et al.  Environment friendly alternatives to halogenated refrigerants—A review , 2009 .

[6]  Ching-Yen Ho,et al.  Evaporation heat transfer and pressure drop characteristics of R-290 (propane), R-600 (butane), and a mixture of R-290/R-600 in the three-lines serpentine small-tube bank , 2005 .

[7]  James M. Calm,et al.  The next generation of refrigerants – Historical review, considerations, and outlook , 2008 .

[8]  M. Elakdhar,et al.  Analysis of a Compression/Ejection Cycle for Domestic Refrigeration , 2007 .

[9]  Li Zhao,et al.  Experimental investigation on pinch points and maximum temperature differences in a horizontal tube-in-tube evaporator using zeotropic refrigerants , 2012 .

[10]  Hyun Joon Chung,et al.  Performance optimization of a Lorenz–Meutzner cycle charged with hydrocarbon mixtures for a domestic refrigerator-freezer , 2012 .

[11]  Bukola Olalekan Bolaji,et al.  Ozone depletion and global warming: Case for the use of natural refrigerant – a review , 2013 .

[12]  M. Wen,et al.  Condensation heat transfer and pressure drop characteristics of R-290 (propane), R-600 (butane), and a mixture of R-290/R-600 in the serpentine small-tube bank , 2006 .

[13]  Jianlin Yu,et al.  Theoretical investigation on an ejector–expansion refrigeration cycle using zeotropic mixture R290/R600a for applications in domestic refrigerator/freezers , 2015 .

[14]  Weiwu Ma,et al.  Experimental study on household refrigerator with diffuser pipe , 2011 .

[15]  Xing Jin,et al.  A new evaluation method for zeotropic refrigerant mixtures based on the variance of the temperature difference between the refrigerant and heat transfer fluid , 2011 .

[16]  E. Granryd Hydrocarbons as refrigerants — an overview , 2001 .

[17]  Jahar Sarkar,et al.  Optimization of a transcritical CO2 heat pump cycle for simultaneous cooling and heating applications , 2004 .

[18]  S. Wongwises,et al.  Experimental study of hydrocarbon mixtures to replace HFC-134a in a domestic refrigerator , 2005 .

[19]  Zhijing Liu,et al.  Simulation and Test Results of Hydrocarbon Mixtures in a Modified-Lorenz-Meutzner Cycle Domestic Refrigerator , 1995 .

[20]  M. Fatouh,et al.  Experimental evaluation of a domestic refrigerator working with LPG , 2006 .

[21]  Li Zhao,et al.  Experimental research on the influence of system parameters on the composition shift for zeotropic mixture (isobutane/pentane) in a system occurring phase change , 2016 .

[22]  Yiping Dai,et al.  Exergy analysis, parametric analysis and optimization for a novel combined power and ejector refrigeration cycle , 2009 .

[23]  Jianlin Yu,et al.  Performance evaluation on an internal auto-cascade refrigeration cycle with mixture refrigerant R290/R600a , 2015 .

[24]  Omar Abdelaziz,et al.  Advances in household appliances- A review , 2011 .

[25]  Mingyan Zhang,et al.  Compression-injection hybrid refrigeration cycles in household refrigerators , 2010 .

[26]  Hyun Joon Chung,et al.  Performance optimization of dual-loop cycles using R-600a and hydrocarbon mixtures designed for a domestic refrigerator-freezer , 2012 .

[27]  José Fernández-Seara,et al.  Theoretical analysis of a CO2–NH3 cascade refrigeration system for cooling applications at low temperatures , 2009 .

[28]  Juan M. Belman-Flores,et al.  Enhancements in domestic refrigeration, approaching a sustainable refrigerator – A review , 2015 .

[29]  Leelananda Rajapaksha,et al.  Influence of special attributes of zeotropic refrigerant mixtures on design and operation of vapour compression refrigeration and heat pump systems , 2007 .