Analysis of the measurement precision of arterial lumen and wall areas using high‐resolution MRI

High‐resolution MRI may be used to monitor the progression of human carotid atherosclerosis by measuring the lumen and wall area changes over time. The purpose of this study was to analyze the precision of quantitative measurements of lumen and wall areas. Two independent MR scans near the carotid bifurcation were conducted on eight patients within 2 weeks. The error of lumen area measurement was 6.2%, 9.2%, and 9.7% for T1, proton density, and T2‐weighted images, respectively, and the error of wall area measurement was 10.8%, 10.9%, and 12.0%. The precision of area measurement correlates strongly with image quality. Magn Reson Med 44:968–972, 2000. © 2000 Wiley‐Liss, Inc.

[1]  C Yuan,et al.  Closed contour edge detection of blood vessel lumen and outer wall boundaries in black-blood MR images. , 1999, Magnetic resonance imaging.

[2]  E A Fisher,et al.  Noninvasive In vivo high-resolution magnetic resonance imaging of atherosclerotic lesions in genetically engineered mice. , 1998, Circulation.

[3]  J R Brookeman,et al.  Noninvasive quantitative evaluation of atherosclerosis using MRI and image analysis. , 1993, Arteriosclerosis and thrombosis : a journal of vascular biology.

[4]  C Yuan,et al.  Phased‐Array Magnetic Resonance Imaging of the Carotid Artery Bifurcation: Preliminary Results in Healthy Volunteers and a Patient with Aherosclerotic Disease , 1995, Journal of magnetic resonance imaging : JMRI.

[5]  C Yuan,et al.  Surface coil phased arrays for high‐resolution imaging of the carotid arteries , 1996, Journal of magnetic resonance imaging : JMRI.

[6]  C Yuan,et al.  Measurement of atherosclerotic carotid plaque size in vivo using high resolution magnetic resonance imaging. , 1998, Circulation.

[7]  W D Wagner,et al.  A definition of advanced types of atherosclerotic lesions and a histological classification of atherosclerosis. A report from the Committee on Vascular Lesions of the Council on Arteriosclerosis, American Heart Association. , 1995, Arteriosclerosis, thrombosis, and vascular biology.

[8]  In Vivo MR Evaluation of Atherosclerosis in Human Carotid Artery with Use of Phased-Array Coils , 1996 .

[9]  H Quan,et al.  Assessing reproducibility by the within-subject coefficient of variation with random effects models. , 1996, Biometrics.

[10]  T. J. Breen,et al.  Biostatistical Analysis (2nd ed.). , 1986 .

[11]  A. Simon,et al.  Distribution of ultrasonographically-assessed dimensions of common carotid arteries in healthy adults of both sexes. , 2000, Atherosclerosis.

[12]  M B Merickel,et al.  Assessment of the reliability of the determination of carotid artery lumen sizes by quantitative image processing of magnetic resonance angiograms and images. , 1995, Magnetic resonance imaging.

[13]  R R Edelman,et al.  Extracranial carotid arteries: evaluation with "black blood" MR angiography. , 1990, Radiology.

[14]  J W Murakami,et al.  Intensity correction of phased‐array surface coil images , 1996, Magnetic resonance in medicine.

[15]  L. Lin,et al.  A concordance correlation coefficient to evaluate reproducibility. , 1989, Biometrics.