Two-dimensional paper networks: programmable fluidic disconnects for multi-step processes in shaped paper.

Most laboratory assays take advantage of multi-step protocols to achieve high performance, but conventional paper-based tests (e.g., lateral flow tests) are generally limited to assays that can be carried out in a single fluidic step. We have developed two-dimensional paper networks (2DPNs) that use materials from lateral flow tests but reconfigure them to enable programming of multi-step reagent delivery sequences. The 2DPN uses multiple converging fluid inlets to control the arrival time of each fluid to a detection zone or reaction zone, and it requires a method to disconnect each fluid source in a corresponding timed sequence. Here, we present a method that allows programmed disconnection of fluid sources required for multi-step delivery. A 2DPN with legs of different lengths is inserted into a shared buffer well, and the dropping fluid surface disconnects each leg at in a programmable sequence. This approach could enable multi-step laboratory assays to be converted into simple point-of-care devices that have high performance yet remain easy to use.

[1]  George M Whitesides,et al.  Integration of paper-based microfluidic devices with commercial electrochemical readers. , 2010, Lab on a chip.

[2]  Richard Lucas,et al.  Ueber das Zeitgesetz des kapillaren Aufstiegs von Flüssigkeiten , 1918 .

[3]  Orawon Chailapakul,et al.  Electrochemical detection for paper-based microfluidics. , 2009, Analytical chemistry.

[4]  G. Whitesides,et al.  Thread as a matrix for biomedical assays. , 2010, ACS applied materials & interfaces.

[5]  Orawon Chailapakul,et al.  Use of multiple colorimetric indicators for paper-based microfluidic devices. , 2010, Analytica chimica acta.

[6]  D. A. Barry,et al.  A class of exact solutions for Richards' equation , 1993 .

[7]  W. Dungchai,et al.  Lab-on-paper with dual electrochemical/colorimetric detection for simultaneous determination of gold and iron. , 2010, Analytical chemistry.

[8]  S. S. Sibbett,et al.  Multiplex lateral-flow test strips fabricated by two-dimensional shaping. , 2009, ACS applied materials & interfaces.

[9]  G. Whitesides,et al.  Simple telemedicine for developing regions: camera phones and paper-based microfluidic devices for real-time, off-site diagnosis. , 2008, Analytical chemistry.

[10]  Wei Shen,et al.  Thread as a versatile material for low-cost microfluidic diagnostics. , 2010, ACS applied materials & interfaces.

[11]  G. Whitesides,et al.  Three-dimensional microfluidic devices fabricated in layered paper and tape , 2008, Proceedings of the National Academy of Sciences.

[12]  Wei Shen,et al.  Quantitative biomarker assay with microfluidic paper-based analytical devices , 2010, Analytical and bioanalytical chemistry.

[13]  B. Lin,et al.  Fabrication and characterization of paper-based microfluidics prepared in nitrocellulose membrane by wax printing. , 2010, Analytical chemistry.

[14]  S. Aguirre,et al.  Paper-based bioassays using gold nanoparticle colorimetric probes. , 2008, Analytical chemistry.

[15]  Paul Yager,et al.  Transport in two-dimensional paper networks , 2011, Microfluidics and nanofluidics.

[16]  Zhihong Nie,et al.  Programmable diagnostic devices made from paper and tape. , 2010, Lab on a chip.

[17]  S. T. Phillips,et al.  Fluidic timers for time-dependent, point-of-care assays on paper. , 2010, Analytical chemistry.

[18]  P. Yager,et al.  Controlled reagent transport in disposable 2D paper networks. , 2010, Lab on a chip.

[19]  Paul Yager,et al.  Chemical signal amplification in two-dimensional paper networks. , 2010, Sensors and actuators. B, Chemical.

[20]  D. A. Barry,et al.  Comment on "An analytic solution of capillary rise restrained by gravity" by N. Fries and M. Dreyer. , 2009, Journal of Colloid and Interface Science.

[21]  Wei Wang,et al.  Tree-shaped paper strip for semiquantitative colorimetric detection of protein with self-calibration. , 2010, Journal of chromatography. A.

[22]  Wei Shen,et al.  Fabrication of paper-based microfluidic sensors by printing. , 2010, Colloids and surfaces. B, Biointerfaces.

[23]  G. Whitesides,et al.  Diagnostics for the developing world: microfluidic paper-based analytical devices. , 2010, Analytical chemistry.

[24]  Paul Yager,et al.  Enhanced sensitivity of lateral flow tests using a two-dimensional paper network format. , 2011, Analytical chemistry.

[25]  J. L. Delaney,et al.  Electrogenerated chemiluminescence detection in paper-based microfluidic sensors. , 2011, Analytical chemistry.

[26]  N. Fries,et al.  An analytic solution of capillary rise restrained by gravity. , 2008, Journal of colloid and interface science.

[27]  Daniel Citterio,et al.  Inkjet-printed paperfluidic immuno-chemical sensing device , 2010, Analytical and bioanalytical chemistry.

[28]  George M Whitesides,et al.  Electrochemical sensing in paper-based microfluidic devices. , 2010, Lab on a chip.

[29]  E. W. Washburn The Dynamics of Capillary Flow , 1921 .

[30]  A. Gobbi,et al.  Electrochemical detection in a paper-based separation device. , 2010, Analytical chemistry.

[31]  Peter Kauffman,et al.  Microfluidics without pumps: reinventing the T-sensor and H-filter in paper networks. , 2010, Lab on a chip.

[32]  Paul Yager,et al.  Visualization and measurement of flow in two-dimensional paper networks. , 2010, Lab on a chip.

[33]  Xu Li,et al.  Flow control concepts for thread-based microfluidic devices. , 2011, Biomicrofluidics.

[34]  Elain FuStephen Transport in two-dimensional paper networks , 2011 .

[35]  Robert Pelton,et al.  Bioactive paper provides a low-cost platform for diagnostics , 2009, TrAC Trends in Analytical Chemistry.

[36]  S. T. Phillips,et al.  Metering the capillary-driven flow of fluids in paper-based microfluidic devices. , 2010, Analytical chemistry.