In vivo retinal imaging for fixational eye motion detection using a high-speed digital micromirror device (DMD)-based ophthalmoscope.

Retinal motion detection with an accuracy of 0.77 arcmin corresponding to 3.7 µm on the retina is demonstrated with a novel digital micromirror device based ophthalmoscope. By generating a confocal image as a reference, eye motion could be measured from consecutively measured subsampled frames. The subsampled frames provide 7.7 millisecond snapshots of the retina without motion artifacts between the image points of the subsampled frame, distributed over the full field of view. An ophthalmoscope pattern projection speed of 130 Hz enabled a motion detection bandwidth of 65 Hz. A model eye with a scanning mirror was built to test the performance of the motion detection algorithm. Furthermore, an in vivo motion trace was obtained from a healthy volunteer. The obtained eye motion trace clearly shows the three main types of fixational eye movements. Lastly, the obtained eye motion trace was used to correct for the eye motion in consecutively obtained subsampled frames to produce an averaged confocal image correct for motion artefacts.

[1]  E. B. Huey,et al.  Preliminary experiments in the physiology and psychology of reading , 1898 .

[2]  R. W. Ditchburn,et al.  Involuntary eye movements during fixation , 1953, The Journal of physiology.

[3]  A. Drysdale The visibility of retinal blood vessels , 1975, Vision Research.

[4]  R. Webb,et al.  Confocal scanning laser ophthalmoscope. , 1987, Applied optics.

[5]  Robert H. Webb,et al.  Scanning Laser Ophthalmoscope , 1981, IEEE Transactions on Biomedical Engineering.

[6]  Vassilios Sarafis,et al.  Resolution enhancement by subtraction of confocal signals taken at different pinhole sizes. , 2003, Micron.

[7]  Kenichi Saito,et al.  Closed-loop optical stabilization and digital image registration in adaptive optics scanning light ophthalmoscopy. , 2014, Biomedical optics express.

[8]  Austin Roorda,et al.  Retinal motion estimation in adaptive optics scanning laser ophthalmoscopy. , 2006, Optics express.

[9]  Larry J. Hornbeck,et al.  Digital Light Processing for high-brightness high-resolution applications , 1997, Electronic Imaging.

[10]  J. Findlay Frequency analysis of human involuntary eye movement , 1971, Kybernetik.

[11]  Phillip Bedggood,et al.  De-warping of images and improved eye tracking for the scanning laser ophthalmoscope , 2017, PloS one.

[12]  G. Timberlake,et al.  A Novel Method for Measuring Saccade Profiles Using the Scanning Laser Ophthalmoscope , 1996, Vision Research.

[13]  Austin Roorda,et al.  Design of an integrated hardware interface for AOSLO image capture and cone-targeted stimulus delivery , 2010, Optics express.

[14]  H D Crane,et al.  Accurate two-dimensional eye tracker using first and fourth Purkinje images. , 1973, Journal of the Optical Society of America.

[15]  H D Crane,et al.  Generation-V dual-Purkinje-image eyetracker. , 1985, Applied optics.

[16]  Ahmadreza Baghaie,et al.  An Automated Reference Frame Selection (ARFS) Algorithm for Cone Imaging with Adaptive Optics Scanning Light Ophthalmoscopy , 2017, Translational vision science & technology.

[17]  Sina Farsiu,et al.  Handheld simultaneous scanning laser ophthalmoscopy and optical coherence tomography system. , 2013, Biomedical optics express.

[18]  Marconi Barbosa,et al.  Joint iris boundary detection and fit: a real-time method for accurate pupil tracking , 2014, Biomedical optics express.

[19]  E DeHoog,et al.  Optimal parameters for retinal illumination and imaging in fundus cameras. , 2008, Applied optics.

[20]  Austin Roorda,et al.  High-speed, image-based eye tracking with a scanning laser ophthalmoscope , 2012, Biomedical optics express.

[21]  John Magill,et al.  Image stabilization for scanning laser ophthalmoscopy. , 2002, Optics express.

[22]  L. Riggs,et al.  The disappearance of steadily fixated visual test objects. , 1953, Journal of the Optical Society of America.

[23]  Austin Roorda,et al.  Real-time eye motion compensation for OCT imaging with tracking SLO , 2012, Biomedical optics express.

[24]  D. Hubel,et al.  The role of fixational eye movements in visual perception , 2004, Nature Reviews Neuroscience.

[25]  Johannes F de Boer,et al.  Digital micromirror device based ophthalmoscope with concentric circle scanning. , 2017, Biomedical optics express.

[26]  R. W. DITCHBURN,et al.  Vision with a Stabilized Retinal Image , 1952, Nature.

[27]  Harvey F. Silverman,et al.  A Class of Algorithms for Fast Digital Image Registration , 1972, IEEE Transactions on Computers.

[28]  D. Robinson,et al.  A METHOD OF MEASURING EYE MOVEMENT USING A SCLERAL SEARCH COIL IN A MAGNETIC FIELD. , 1963, IEEE transactions on bio-medical engineering.

[29]  Robert H. Webb,et al.  Fundus tracking with the scanning laser ophthalmoscope. , 1987, Applied optics.

[30]  T N CORNSWEET,et al.  New technique for the measurement of small eye movements. , 1958, Journal of the Optical Society of America.

[31]  Austin Roorda,et al.  Retinally stabilized cone-targeted stimulus delivery. , 2007, Optics express.

[32]  H. Collewijn,et al.  Instability of ocular torsion during fixation: Cyclovergence is more stable than cycloversion , 1994, Vision Research.

[33]  S. Martinez-Conde,et al.  Integrative Neuroscience Review Article Fixational Eye Movements and Binocular Vision , 2022 .

[34]  David Mas,et al.  Pupil detection and tracking for analysis of fixational eye micromovements , 2012 .

[35]  Johannes F de Boer,et al.  Parallel line scanning ophthalmoscope for retinal imaging. , 2015, Optics letters.

[36]  R. W. Ditchburn,et al.  Vision with controlled movements of the retinal image , 1959, The Journal of physiology.