Dual energy CT-based characterization of x-ray attenuation properties of breast equivalent material plates

Breast density is more and more considered as an important risk factor for breast cancer and several quantitative breast density evaluation methods have been proposed. The reference material for simulation of the breast attenuation properties of glandular and adipose breast tissues is manufactured by a single provider. In order to characterize the attenuation properties of these materials, measurements in Hounsfield Units (HU) have been performed using a CT-scanner. Breastequivalent plates have been imaged in different configurations (plates in and orthogonal to image planes), providing consistent results (± 1.3 HU). Breast density equivalent plates of different nominal breast density equivalences and sizes were measured, demonstrating both a good homogeneity within the plates (± 1.8 HU) and a good consistency between plates of the same nominal breast density equivalence (± 1.5 HU). In addition, dual energy CT provided mono-energetic HU from which mono-energetic linear attenuation coefficients of water and glandular and adipose equivalent materials were computed. The values for these coefficients were found in good agreement with results from literature, respectively direct mono-energetic measurements of breast samples, and computation by combining published breast tissue atomic compositions and linear attenuation coefficient tables. In conclusion, CT was found effective for the verification of the breast equivalent material, and the homogeneity and consistency of the plates were found satisfactory. Furthermore, the most recent spectral CT technology allowed demonstrating a good agreement of the attenuation properties of breastequivalent material plates with state-of-the-art knowledge of real breast tissue attenuation.

[1]  Xinhua Li,et al.  Objective characterization of GE discovery CT750 HD scanner: gemstone spectral imaging mode. , 2011, Medical physics.

[2]  Consumer Protection,et al.  European guidelines for quality assurance in breast cancer screening and diagnosis. Fourth edition--summary document. , 2008, Annals of oncology : official journal of the European Society for Medical Oncology.

[3]  M. Poletti,et al.  X-ray scattering from human breast tissues and breast-equivalent materials. , 2002, Physics in medicine and biology.

[4]  Ralph Highnam,et al.  Volumetric Assessment of Breast Tissue Composition from FFDM Images , 2008, Digital Mammography / IWDM.

[5]  J. Harvey,et al.  Breast cancer—facts and figures , 2013 .

[6]  M. Yaffe,et al.  Validation of a method for measuring the volumetric breast density from digital mammograms , 2010, Physics in medicine and biology.

[7]  R Holland,et al.  European guidelines for quality assurance in breast cancer screening and diagnosis. Fourth edition--summary document. , 2008, Annals of Oncology.

[8]  M. E. Masterson,et al.  Epoxy-resin-based tissue substitutes. , 1977, Medical physics.

[9]  P. C. Johns,et al.  X-ray characterisation of normal and neoplastic breast tissues. , 1987, Physics in medicine and biology.

[10]  Jeff Wang,et al.  Improvements to Single Energy Absorptiometry Method for Digital Mammography to Quantify Breast Tissue Density , 2008, Digital Mammography / IWDM.

[11]  Eric J. Tkaczyk,et al.  Monochromatic CT image representation via fast switching dual kVp , 2009, Medical Imaging.

[12]  V. McCormack,et al.  Breast Density and Parenchymal Patterns as Markers of Breast Cancer Risk: A Meta-analysis , 2006, Cancer Epidemiology Biomarkers & Prevention.

[13]  Nico Karssemeijer,et al.  Robust breast composition measurement - Volpara™ , 2010 .

[14]  J. S. Laughlin,et al.  Absorbed radiation dose in mammography. , 1979, Radiology.

[15]  S. Cummings,et al.  Single x-ray absorptiometry method for the quantitative mammographic measure of fibroglandular tissue volume. , 2009, Medical physics.