Fetal abdominal contour extraction and measurement in ultrasound images.

A novel method is developed for the fetal abdominal contour extraction and measurement in ultrasound images. Fetal abdominal circumference (AC) is one of the standardized measurements in the antepartum ultrasound monitoring. Among several standardized measurements, AC is best correlated with fetal growth but is also the most difficult to be accurately measured. To overcome the difficulties in the abdominal contour extraction, the proposed method is a four-step procedure that integrates several image segmentation techniques. The proposed method is able to make the best use of the strength of different segmentation algorithms, while avoiding their deficiencies. An enhanced instantaneous coefficient of variation (ICOV) edge detector is first developed to detect edges of the abdominal contour and alleviate the effects of most speckle noise. Then, the Fuzzy C-Means clustering is employed to distinguish salient edges attributable to the abdominal contour from weak edges due to the other texture. Subsequently, the iterative Hough transform is applied to determine an elliptical contour and obtain an initial estimation of the AC. Finally, the gradient vector field (GVF) snake adapts the initial ellipse to the real edges of the abdominal contour. Quantitative validation of the proposed method on synthetic images under different imaging conditions achieves satisfactory segmentation accuracy (98.78%+/-0.16%). Experiments on 150 clinical images are carried out in three aspects: comparisons between inter-observer and inter-run variation, the fitness analysis between the automatically detected ellipse and the manual delineation, and the accuracy comparisons between automatic measurements and manual measurements in estimation of fetal weight (EFW). Experimental results show that the proposed method can provide consistent and accurate measurements. The reductions of the mean absolute difference and the standard deviation of EFW based on automatic measurements are about 1.2% and 2.1%, respectively, which indicate its potential in clinical antepartum monitoring application.

[1]  S T Moore,et al.  Robust pupil center detection using a curvature algorithm. , 1999, Computer methods and programs in biomedicine.

[2]  N. Dudley A systematic review of the ultrasound estimation of fetal weight , 2005, Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology.

[3]  Zhi-Qiang Liu,et al.  A robust, real-time ellipse detector , 2005, Pattern Recognit..

[4]  Philippe Marthon,et al.  An optimal multiedge detector for SAR image segmentation , 1998, IEEE Trans. Geosci. Remote. Sens..

[5]  John F. Canny,et al.  A Computational Approach to Edge Detection , 1986, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[6]  John W. Clark,et al.  Nonlinear multiscale wavelet diffusion for speckle suppression and edge enhancement in ultrasound images , 2006, IEEE Transactions on Medical Imaging.

[7]  Piero Tortoli,et al.  Intraluminal ultrasound intensity distribution and backscattered Doppler power. , 2004, Ultrasound in medicine & biology.

[8]  Scott T. Acton,et al.  Speckle reducing anisotropic diffusion , 2002, IEEE Trans. Image Process..

[9]  J. Alison Noble,et al.  Ultrasound image segmentation: a survey , 2006, IEEE Transactions on Medical Imaging.

[10]  C. Lamberti,et al.  Maximum likelihood segmentation of ultrasound images with Rayleigh distribution , 2005, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[11]  Jerry L. Prince,et al.  Snakes, shapes, and gradient vector flow , 1998, IEEE Trans. Image Process..

[12]  Solange Akselrod,et al.  Automatic Endocardial-Boundary Detection in Low Mechanical-Index Contrast Echocardiography , 2006, IEEE Transactions on Biomedical Engineering.

[13]  Demetri Terzopoulos,et al.  Snakes: Active contour models , 2004, International Journal of Computer Vision.

[14]  Robert Rohling,et al.  Methods for segmenting curved needles in ultrasound images , 2006, Medical Image Anal..

[15]  James C. Bezdek,et al.  A Convergence Theorem for the Fuzzy ISODATA Clustering Algorithms , 1980, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[16]  Josef Kittler,et al.  Detecting partially occluded ellipses using the Hough transform , 1989, Image Vis. Comput..

[17]  Yonina C. Eldar,et al.  A probabilistic Hough transform , 1991, Pattern Recognit..

[18]  Milan Sonka,et al.  Ovarian ultrasound image analysis: follicle segmentation , 1998, IEEE Transactions on Medical Imaging.

[19]  Erkki Oja,et al.  A new curve detection method: Randomized Hough transform (RHT) , 1990, Pattern Recognit. Lett..

[20]  Robert Rohling,et al.  Ultrasound image segmentation using spectral clustering. , 2005, Ultrasound in medicine & biology.

[21]  S. Campbell,et al.  ULTRASONIC MEASUREMENT OF FETAL ABDOMEN CIRCUMFERENCE IN THE ESTIMATION OF FETAL WEIGHT , 1975, British journal of obstetrics and gynaecology.

[22]  W D Richard,et al.  Automated texture-based segmentation of ultrasound images of the prostate. , 1996, Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society.

[23]  Yongmin Kim,et al.  Edge-guided boundary delineation in prostate ultrasound images , 2000, IEEE Transactions on Medical Imaging.

[24]  Robert M. Haralick,et al.  Zero Crossing Of Second Directional Derivative Edge Operator , 1982, Other Conferences.

[25]  S Akselrod,et al.  A two-dimensional extension of minimum cross entropy thresholding for the segmentation of ultrasound images. , 1996, Ultrasound in medicine & biology.

[26]  Yee-Hong Yang,et al.  Multiresolution texture segmentation with application to diagnostic ultrasound images , 1993, IEEE Trans. Medical Imaging.

[27]  Scott T. Acton,et al.  Edge detection in ultrasound imagery using the instantaneous coefficient of variation , 2004, IEEE Transactions on Image Processing.

[28]  Ruey-Feng Chang,et al.  3-D snake for US in margin evaluation for malignant breast tumor excision using mammotome , 2003, IEEE Transactions on Information Technology in Biomedicine.

[29]  Jinglu Tan,et al.  Automated fetal head detection and measurement in ultrasound images by iterative randomized Hough transform. , 2005, Ultrasound in medicine & biology.

[30]  F. P. Hadlock,et al.  Sonographic estimation of fetal weight. The value of femur length in addition to head and abdomen measurements. , 1984, Radiology.