Determination of the optimum heat rejection pressure in transcritical cycles working with R744/R290 mixture

Abstract The simulation and experimental investigations have been carried out to research the relationships between optimum heat rejection pressure and related operating parameters for a transcritical system using R744/R290 mixture as a refrigerant. The system is characterised by two expansion valves in series in order to conveniently control the heat rejection pressure. A cycle simulation code has been developed, and the simulation results reveal that for a transcritical cycle working with R744/R290 mixture in which the R744 mass fraction is greater than 0.78, there is an optimal heat rejection pressure, under which a maximum system coefficient of performance (COP) can be reached. Furthermore, the researches in this work show that the optimal heat rejection pressure mainly depends on the mass fraction, the outlet refrigerant temperature of the gas cooler, the evaporation temperature whereas the superheat degree and the performance of the given compressor have weak effects on the optimum heat rejection pressure. Based on the orthogonal experimental simulation data, a correlation of the optimal heat rejection pressure with respect to mainly involved parameters is obtained under the specific conditions. The experimental data of optimal heat rejection pressure are in a relatively good agreement with the simulation results.

[1]  Jostein Pettersen,et al.  Fundamental process and system design issues in CO2 vapor compression systems , 2004 .

[2]  Reinhard Radermacher,et al.  Comparison of R-290 and two HFC blends for walk-in refrigeration systems , 2007 .

[3]  Piotr A. Domanski,et al.  Comparitive analysis of an automotive air conditioning systems operating with CO2 and R134a , 2002 .

[4]  Hanqing Wang,et al.  Performance comparison of air source heat pump with R407C and R22 under frosting and defrosting , 2008 .

[5]  J. Corberán,et al.  Review of standards for the use of hydrocarbon refrigerants in A/C, heat pump and refrigeration equipment ☆ , 2008 .

[6]  Friedrich Kauf,et al.  Determination of the optimum high pressure for transcritical CO2-refrigeration cycles , 1999 .

[7]  Jahar Sarkar,et al.  Assessment of blends of CO2 with butane and isobutane as working fluids for heat pump applications , 2009 .

[9]  J. Pettersen,et al.  A new, efficient and environmentally benign system for car air-conditioning , 1993 .

[10]  G Lorentzen,et al.  The use of natural refrigerants: a complete solution to the CFC/HCFC predicament , 1995 .

[11]  Ruzhu Wang,et al.  Perspectives for natural working fluids in China , 2006 .

[12]  Stelios D. Georgiou,et al.  Orthogonal designs for computer experiments , 2011 .

[13]  Xiaowei Fan,et al.  Performance assessment of heat pumps using HFC125/HCs mixtures , 2012 .

[14]  D. B. Jabaraj,et al.  Experimental investigation of HFC407C/HC290/HC600a mixture in a window air conditioner , 2006 .

[15]  Wang Qin,et al.  Experimental studies on a mixture of HFC-32/125/161 as an alternative refrigerant to HCFC-22 in the presence of polyol ester , 2010 .

[16]  Robert J. Moffat,et al.  Describing the Uncertainties in Experimental Results , 1988 .

[17]  R. Radermacher,et al.  Methods for comparing the performance of pure and mixed refrigerants in the vapour compression cycle , 1987 .

[18]  Shengming Liao,et al.  A correlation of optimal heat rejection pressures in transcritical carbon dioxide cycles , 2000 .

[19]  Bu-Xuan Wang,et al.  Experimental investigation of condensation heat transfer and pressure drop of R22, R410A and R407C in mini-tubes , 2012 .

[20]  Min-Soo Kim,et al.  Cooling performance of several CO2/propane mixtures and glide matching with secondary heat transfer fluid , 2008 .

[21]  Jahar Sarkar,et al.  Natural refrigerant-based subcritical and transcritical cycles for high temperature heating , 2007 .