Toward quantitative fluorescence measurements with multicolor flow cytometry

A procedure is presented for calibrating the output of a multicolor flow cytometer in units of antibodies bound per cell (ABC). The procedure involves two steps. First, each of the fluorescence channels of the flow cytometer is calibrated using Ultra Rainbow beads with assigned values of equivalent number of reference fluorophores (ERF). The objective of this step is to establish a linear relation between the fluorescence signal in a given fluorescence channel of multicolor flow cytometers and the value of ERF. The second step involves a biological standard such as a lymphocyte with a known number of antibody binding sites (e.g., CD4 binding sites). The biological standard is incubated with antibodies labeled with one type of fluorophores for a particular fluorescence channel and serves to translate the ERF scale to an ABC scale. A significant part of the two‐step calibration procedure involves the assignment of ERF values to the different populations of Ultra Rainbow beads. The assignment of ERF values quantifies the relative amount of embedded fluorophore mixture in each bead population. It is crucial to insure that the fluorescence signal in a given range of fluorescence emission wavelengths is related linearly to the assigned values of ERF. The biological standard has to posses a known number of binding sites for a given antibody. In addition, this antibody has to be amenable to labeling with different types of fluorophores associated with various fluorescence channels. The present work suggests that all of the requirements for a successful calibration of a multicolor flow cytometer in terms of ABC values can be fulfilled. The calibration procedure is based on firm scientific foundations so that it is easy to envision future improvements in accuracy and ease of implementation. Published 2007 Wiley‐Liss, Inc.

[1]  P. Carayon,et al.  Cytofluorometric quantification of cell-surface antigens by indirect immunofluorescence using monoclonal antibodies. , 1985, Journal of immunological methods.

[2]  A. K. Gaigalas,et al.  Quantitating Fluorescence Intensity From Fluorophore: Assignment of MESF Values , 2005, Journal of research of the National Institute of Standards and Technology.

[3]  D C Liang,et al.  Crystal Structure of Allophycocyanin from Red AlgaePorphyra yezoensis at 2.2-Å Resolution* , 1999, The Journal of Biological Chemistry.

[4]  M. Forman,et al.  Comparative analysis of flow cytometric techniques in assessment of ZAP-70 expression in relation to IgVH mutational status in chronic lymphocytic leukemia. , 2007, American journal of clinical pathology.

[5]  S. Steinbacher,et al.  Isolation, crystallization, crystal structure analysis and refinement of allophycocyanin from the cyanobacterium Spirulina platensis at 2.3 A resolution. , 1995, Journal of molecular biology.

[6]  Howard M. Shapiro,et al.  Practical Flow Cytometry , 1985 .

[7]  Emili Montserrat,et al.  ZAP-70 expression as a surrogate for immunoglobulin-variable-region mutations in chronic lymphocytic leukemia. , 2003, The New England journal of medicine.

[8]  J V Giorgi,et al.  Quantitation of CD38 activation antigen expression on CD8+ T cells in HIV-1 infection using CD4 expression on CD4+ T lymphocytes as a biological calibrator. , 1998, Cytometry.

[9]  Gerald E Marti,et al.  Comparison of fluorescein and phycoerythrin conjugates for quantifying CD20 expression on normal and leukemic B‐cells , 2006, Cytometry. Part B, Clinical cytometry.

[10]  R. Detels,et al.  Effects of HIV-1 Infection on Lymphocyte Phenotypes in Blood Versus Lymph Nodes , 2005, Journal of acquired immune deficiency syndromes.

[11]  J. Chermann,et al.  Surface CD4 density remains constant on lymphocytes of HIV-infected patients in the progression of disease. , 1991, Research in immunology.

[12]  C. Lambert,et al.  Enumeration of peripheral lymphocyte subsets using 6 vs. 4 color staining: A clinical evaluation of a new flowcytometer , 2006, Cytometry. Part B, Clinical cytometry.

[13]  Adolfas K Gaigalas,et al.  Discrepancy in measuring CD4 expression on T‐lymphocytes using fluorescein conjugates in comparison with unimolar CD4‐phycoerythrin conjugates , 2007, Cytometry. Part B, Clinical cytometry.

[14]  P. Norman,et al.  Immunobiology: The immune system in health and disease , 1995 .

[15]  Mario Roederer,et al.  Quality assurance for polychromatic flow cytometry , 2006, Nature Protocols.

[16]  R. Hoffman,et al.  Determination of CD4 antigen density on cells: role of antibody valency, avidity, clones, and conjugation. , 1998, Cytometry.

[17]  R. Hoffman,et al.  Resolution of dimly fluorescent particles: a practical measure of fluorescence sensitivity. , 1998, Cytometry.