Interventricular delay interval optimization in cardiac resynchronization therapy guided by echocardiography versus guided by electrocardiographic QRS interval width.

Present devices for cardiac resynchronization therapy offer the possibility of tailoring the hemodynamic effect of biventricular pacing by optimization of the interventricular delay (VV) beyond atrioventricular (AV)-interval optimization. It was not yet defined whether a QRS width-based strategy may be a helpful tool for echocardiography for device programming. The aim of the study was to investigate the relation between VV-interval optimization guided by echocardiography and guided by QRS interval width. One hundred six patients with a cardiac resynchronization therapy device for > or =3 months were enrolled. All patients underwent echocardiographic AV and VV delay optimization. The AV interval was optimized according to the E wave-A wave (EA) interval and left ventricular filling time. At the optimal AV delay, VV optimization was performed by measuring the aortic velocity time integral at 5 different settings: simultaneous right and left ventricle output, left ventricle pre-excitation (left ventricle + 40 and 80 ms, respectively), and right ventricle pre-excitation (right ventricle + 40 and 80 ms, respectively). A 12-lead electrocardiogram was recorded and QRS duration was measured in the lead with the greatest QRS width. The electrocardiographic (ECG)-optimized VV interval was defined according to the narrowest achievable QRS interval among 5 VV intervals. The echocardiographic-optimized VV interval was left ventricle + 40 ms in 28 patients, left ventricle + 80 ms in 15 patients, simultaneous in 46 patients, right ventricle + 40 ms in 14 patients, and right ventricle + 80 ms in 3 patients. Significant concordance (kappa = 0.69, p <0.001) was found between the echocardiographic- and ECG-optimized VV interval. In conclusion, significant concordance appeared to exist during biventricular pacing between VV programming based on the shortest QRS interval at 12-lead ECG pacing and echocardiographic-guided VV-interval optimization. A combined ECG- and echocardiographic approach could be a less time-consuming solution in performing this operation.

[1]  T. D. de Backer,et al.  Tailored echocardiographic interventricular delay programming further optimizes left ventricular performance after cardiac resynchronization therapy. , 2005, Heart rhythm.

[2]  Milton Packer,et al.  Cardiac resynchronization in chronic heart failure. , 2002, The New England journal of medicine.

[3]  H. Halperin,et al.  Systolic Improvement and Mechanical Resynchronization Does Not Require Electrical Synchrony in the Dilated Failing Heart With Left Bundle-Branch Block , 2002, Circulation.

[4]  Christophe Leclercq,et al.  Cardiac resynchronization therapy: Part 1--issues before device implantation. , 2005, Journal of the American College of Cardiology.

[5]  J. Mayet,et al.  Selection and optimisation of biventricular pacing: the role of echocardiography , 2004, Heart.

[6]  J. Cleland,et al.  Clinical trials update from the European Society of Cardiology Congress 2007: 3CPO, ALOFT, PROSPECT and statins for heart failure , 2007, European journal of heart failure.

[7]  Christophe Leclercq,et al.  Cardiac resynchronization therapy: Part 2--issues during and after device implantation and unresolved questions. , 2005, Journal of the American College of Cardiology.

[8]  L. Padeletti,et al.  Temporal variation in optimal atrioventricular and interventricular delay during cardiac resynchronization therapy. , 2006, Journal of cardiac failure.

[9]  Arma,et al.  EFFECTS OF MULTISITE BIVENTRICULAR PACING IN PATIENTS WITH HEART FAILURE AND INTRAVENTRICULAR CONDUCTION DELAY , 2001 .

[10]  B. Kristensen,et al.  Sequential Versus Simultaneous Biventricular Resynchronization for Severe Heart Failure: Evaluation by Tissue Doppler Imaging , 2002, Circulation.

[11]  E. Leray,et al.  Clinical and electrocardiographic predictors of a positive response to cardiac resynchronization therapy in advanced heart failure. , 2005 .

[12]  Paolo Rizzon,et al.  Ventricular asynchrony predicts a better outcome in patients with chronic heart failure receiving cardiac resynchronization therapy. , 2005, Journal of the American College of Cardiology.

[13]  J. McMurray,et al.  Selecting patients for cardiac resynchronization therapy: electrical or mechanical dyssynchrony? , 2006, European heart journal.

[14]  J. Daubert,et al.  Effects of multisite biventricular pacing in patients with heart failure and intraventricular conduction delay. , 2001, The New England journal of medicine.

[15]  Catherine Klersy,et al.  Interventricular and intraventricular dyssynchrony are common in heart failure patients, regardless of QRS duration. , 2004, European heart journal.

[16]  Gregory S. Nelson,et al.  Left Ventricular or Biventricular Pacing Improves Cardiac Function at Diminished Energy Cost in Patients With Dilated Cardiomyopathy and Left Bundle-Branch Block , 2000, Circulation.

[17]  Giuseppe Boriani,et al.  Randomized comparison of simultaneous biventricular stimulation versus optimized interventricular delay in cardiac resynchronization therapy. The Resynchronization for the HemodYnamic Treatment for Heart Failure Management II implantable cardioverter defibrillator (RHYTHM II ICD) study. , 2006, American heart journal.

[18]  D. Chaleil,et al.  Echocardiographic Assessment of the Interventricular Delay of Activation and Correlation to the QRS Width in Dilated Cardiomyopathy , 2001, Pacing and clinical electrophysiology : PACE.

[19]  Angelo Branzi,et al.  Cardiac Resynchronization Therapy: Variations in Echo‐Guided Optimized Atrioventricular and Interventricular Delays During Follow‐Up , 2007, Echocardiography.

[20]  John Ludbrook,et al.  Statistical Techniques For Comparing Measurers And Methods Of Measurement: A Critical Review , 2002, Clinical and experimental pharmacology & physiology.

[21]  A. Tajik,et al.  Mechanism of hemodynamic improvement by dual-chamber pacing for severe left ventricular dysfunction: an acute Doppler and catheterization hemodynamic study. , 1995, Journal of the American College of Cardiology.

[22]  Jeroen J. Bax,et al.  Left ventricular dyssynchrony predicts response and prognosis after cardiac resynchronization therapy. , 2004, Journal of the American College of Cardiology.

[23]  Cheuk-Man Yu,et al.  Understanding Nonresponders of Cardiac Resynchronization Therapy—Current and Future Perspectives , 2005, Journal of cardiovascular electrophysiology.

[24]  J. Daubert,et al.  Electrocardiographic predictive factors of long-term clinical improvement with multisite biventricular pacing in advanced heart failure. , 1999, The American journal of cardiology.

[25]  W. Braham,et al.  Cardiac Resynchronization in Chronic Heart Failure , 2002 .

[26]  A. Lazarus,et al.  Sequential Biventricular Pacing: , 2004, Pacing and clinical electrophysiology : PACE.

[27]  Jeroen J. Bax,et al.  Clinical versus echocardiographic parameters to assess response to cardiac resynchronization therapy. , 2006, The American journal of cardiology.