Real-time MR navigation and localization of an intravascular catheter with ferromagnetic components

ObjectTo develop an intravascular catheter with ferromagnetic components that is navigated with MR gradient forces and imaged with dedicated MR sequences in real time.Materials and methodsThe orientation of a device with ferromagnetic components can be controlled by gradient forces. In this work, a 3D input device for interactive real-time control of the force gradient was combined with a dedicated real-time MR pulse sequence. The pulse sequence offered acquisition of FLASH images, force gradient and localization of the ferromagnetic tip with three projections. The technique for localization is a combination of off-set resonance excitation and gradient rephasing. According to the position of the ferromagnetic components from the projections, the imaging slice is automatically aligned with the ferromagnetic component. The navigation methods and localization techniques were assessed in phantom and animal studies.ResultsAt a reaction time of 24 ms and a frame rate of one image per second, the orientation of a ferromagnetic catheter could be navigated in a complex vascular phantom. The magnetic force generated by a gradient of 28 mT/m could reach up to 100±20 μN. The localization of the ferromagnetic tip could be performed with an uncertainty of 1 mm in phantom studies and 4 mm in animal studies.ConclusionThe use of a deflectable catheter with a ferromagnetic tip to target the blood vessels and localize the position of device provides a novel method to use the MR system to image the anatomy and steer an interventional device which helps to increase the precision and speed of endovascular procedures.

[1]  R. Seibel,et al.  Interventional MRI: update , 1997, European Radiology.

[2]  S. Martel,et al.  Automatic navigation of an untethered device in the artery of a living animal using a conventional clinical magnetic resonance imaging system , 2007 .

[3]  Wolfhard Semmler,et al.  Dynamic coil selection for real‐time imaging in interventional MRI , 2006, Magnetic resonance in medicine.

[4]  Michel E. Mawad,et al.  Guglielmi detachable coil embolization of acute intracranial aneurysm , 1997 .

[5]  Gilles Beaudoin,et al.  In Vivo MR-Tracking Based on Magnetic Signature Selective Excitation , 2008, IEEE Transactions on Medical Imaging.

[6]  Sylvain Martel,et al.  Adapting the clinical MRI software environment for real‐time navigation of an endovascular untethered ferromagnetic bead for future endovascular interventions , 2008, Magnetic resonance in medicine.

[7]  Gabriel Acevedo-Bolton,et al.  MR imaging during endovascular procedures: An evaluation of the potential for catheter heating , 2009, Magnetic resonance in medicine.

[8]  G. Duckwiler,et al.  Guglielmi detachable coil embolization of acute intracranial aneurysm: perioperative anatomical and clinical outcome in 403 patients. , 1997, Journal of neurosurgery.

[9]  Wolfhard Semmler,et al.  An expandable catheter loop coil for intravascular MRI in larger blood vessels , 2010, Magnetic resonance in medicine.

[10]  R. Higashida,et al.  Causes and management of aneurysmal hemorrhage occurring during embolization with Guglielmi detachable coils. , 1998, Journal of neurosurgery.

[11]  Xiaoping Hu,et al.  Off‐resonance saturation as a means of generating contrast with superparamagnetic nanoparticles , 2006, Magnetic resonance in medicine.

[12]  John M Pauly,et al.  Positive contrast magnetic resonance imaging of cells labeled with magnetic nanoparticles , 2005, Magnetic resonance in medicine.

[13]  Wei Liu,et al.  Susceptibility gradient mapping (SGM): A new postprocessing method for positive contrast generation applied to superparamagnetic iron oxide particle (SPIO)‐labeled cells , 2008, Magnetic resonance in medicine.

[14]  Sylvain Martel,et al.  Method of propulsion of a ferromagnetic core in the cardiovascular system through magnetic gradients generated by an MRI system , 2006, IEEE Transactions on Biomedical Engineering.

[15]  A. Cavalcanti,et al.  Nanorobotics control design: a collective behavior approach for medicine , 2005, IEEE Transactions on NanoBioscience.

[16]  Matthias Stuber,et al.  Positive contrast visualization of iron oxide‐labeled stem cells using inversion‐recovery with ON‐resonant water suppression (IRON) , 2007, Magnetic resonance in medicine.

[17]  Wolfhard Semmler,et al.  Active catheter tracking using parallel MRI and real‐time image reconstruction , 2006, Magnetic resonance in medicine.

[18]  Sylvain Martel,et al.  Preliminary investigation of the feasibility of magnetic propulsion for future microdevices in blood vessels. , 2005, Bio-medical materials and engineering.

[19]  Sylvain Martel,et al.  Real-Time MRI-Based Control of a Ferromagnetic Core for Endovascular Navigation , 2008, IEEE Transactions on Biomedical Engineering.

[20]  Max A Viergever,et al.  Passive tracking exploiting local signal conservation: The white marker phenomenon , 2003, Magnetic resonance in medicine.

[21]  Kim Butts,et al.  Reduction of blurring in view angle tilting MRI , 2005, Magnetic resonance in medicine.

[22]  John M Pauly,et al.  SEMAC: Slice encoding for metal artifact correction in MRI , 2009, Magnetic resonance in medicine.

[23]  Wolfhard Semmler,et al.  MR‐guided intravascular procedures: Real‐time parameter control and automated slice positioning with active tracking coils , 2004, Journal of magnetic resonance imaging : JMRI.

[24]  R L Arenson,et al.  Remote control of catheter tip deflection: An opportunity for interventional MRI , 2002, Magnetic resonance in medicine.

[25]  Jonathan S. Lewin,et al.  A brief review of hardware for catheter tracking in magnetic resonance imaging , 2001, Magnetic Resonance Materials in Physics, Biology and Medicine.

[26]  Deniz Bilecen,et al.  MR-guided endovascular interventions: a comprehensive review on techniques and applications , 2008, European Radiology.