Robotic Hand–Assisted Training for Spinal Cord Injury Driven by Myoelectric Pattern Recognition: A Case Report

Abstract A 51-year-old man with an incomplete C6 spinal cord injury sustained 26 yrs ago attended twenty 2-hr visits over 10 wks for robot-assisted hand training driven by myoelectric pattern recognition. In each visit, his right hand was assisted to perform motions by an exoskeleton robot, while the robot was triggered by his own motion intentions. The hand robot was designed for this study, which can perform six kinds of motions, including hand closing/opening; thumb, index finger, and middle finger closing/opening; and middle, ring, and little fingers closing/opening. After the training, his grip force increased from 13.5 to 19.6 kg, his pinch force remained the same (5.0 kg), his score of Box and Block test increased from 32 to 39, and his score from the Graded Redefined Assessment of Strength, Sensibility, and Prehension test Part 4.B increased from 22 to 24. He accomplished the tasks in the Graded Redefined Assessment of Strength, Sensibility, and Prehension test Part 4.B 28.8% faster on average. The results demonstrate the feasibility and effectiveness of robot-assisted training driven by myoelectric pattern recognition after spinal cord injury.

[1]  Mamun Bin Ibne Reaz,et al.  Surface Electromyography Signal Processing and Classification Techniques , 2013, Sensors.

[2]  K. Y. Tong,et al.  An EMG-driven exoskeleton hand robotic training device on chronic stroke subjects: Task training system for stroke rehabilitation , 2011, 2011 IEEE International Conference on Rehabilitation Robotics.

[3]  Chih-Jen Lin,et al.  LIBSVM: A library for support vector machines , 2011, TIST.

[4]  B Hudgins,et al.  Myoelectric signal processing for control of powered limb prostheses. , 2006, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[5]  Ping Zhou,et al.  A Novel Myoelectric Pattern Recognition Strategy for Hand Function Restoration After Incomplete Cervical Spinal Cord Injury , 2013, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[6]  E. A. Susanto,et al.  The effects of post-stroke upper-limb training with an electromyography (EMG)-driven hand robot. , 2013, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[7]  M. Popovic,et al.  The Graded Redefined Assessment of Strength Sensibility and Prehension: reliability and validity. , 2012, Journal of neurotrauma.

[8]  Asha,et al.  A Hand Gesture Recognition Framework and Wearable Gesture Based Interaction Prototype for Mobile Devices , 2015 .

[9]  G de Groot,et al.  The strength of the hand. , 1970, Bulletin of prosthetics research.

[10]  C. Burgar,et al.  Quantification of force abnormalities during passive and active-assisted upper-limb reaching movements in post-stroke hemiparesis , 1999, IEEE Transactions on Biomedical Engineering.

[11]  Soo-Jin Lee,et al.  Current hand exoskeleton technologies for rehabilitation and assistive engineering , 2012 .

[12]  Ying Wu,et al.  Modeling the constraints of human hand motion , 2000, Proceedings Workshop on Human Motion.

[13]  Terry Caelli,et al.  A Syntactic Two-Component Encoding Model for the Trajectories of Human Actions , 2014, IEEE Journal of Biomedical and Health Informatics.

[14]  Carlo Menon,et al.  Surface EMG pattern recognition for real-time control of a wrist exoskeleton , 2010, Biomedical engineering online.

[15]  Le Li,et al.  Assistive Control System Using Continuous Myoelectric Signal in Robot-Aided Arm Training for Patients After Stroke , 2008, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[16]  Huosheng Hu,et al.  Myoelectric control systems - A survey , 2007, Biomed. Signal Process. Control..

[17]  V. Mathiowetz,et al.  Adult norms for the Box and Block Test of manual dexterity. , 1985, The American journal of occupational therapy : official publication of the American Occupational Therapy Association.

[18]  C. Burgar,et al.  Robot-assisted movement training compared with conventional therapy techniques for the rehabilitation of upper-limb motor function after stroke. , 2002, Archives of physical medicine and rehabilitation.

[19]  Grant D. Huang,et al.  An Economic Analysis of Robot-Assisted Therapy for Long-Term Upper-Limb Impairment After Stroke , 2011, Stroke.

[20]  Rahsaan J. Holley,et al.  Development and pilot testing of HEXORR: Hand EXOskeleton Rehabilitation Robot , 2010, Journal of NeuroEngineering and Rehabilitation.

[21]  Fuchun Sun,et al.  sEMG-Based Joint Force Control for an Upper-Limb Power-Assist Exoskeleton Robot , 2014, IEEE Journal of Biomedical and Health Informatics.

[22]  Rong Song,et al.  A Comparison Between Electromyography-Driven Robot and Passive Motion Device on Wrist Rehabilitation for Chronic Stroke , 2009, Neurorehabilitation and neural repair.

[23]  K. Tong,et al.  Effects of electromyography-driven robot-aided hand training with neuromuscular electrical stimulation on hand control performance after chronic stroke , 2015, Disability and rehabilitation. Assistive technology.