Multiple Wavelength Optical Coherence Tomography Assessments for Enhanced Ex Vivo Intra-Cochlear Microstructural Visualization

The precise identification of intra-cochlear microstructures is an essential otorhinolaryngological requirement to diagnose the progression of cochlea related diseases. Thus, we demonstrated an experimental procedure to investigate the most optimal wavelength range, which can enhance the visualization of ex vivo intra-cochlear microstructures using multiple wavelengths (i.e., 860 nm, 1060 nm, and 1300 nm) based optical coherence tomography (OCT) systems. The high-resolution tomograms, volumetric, and quantitative evaluations obtained from Basilar membrane, organ of Corti, and scala vestibule regions revealed complementary comparisons between the aforementioned three distinct wavelengths based OCT systems. Compared to 860 nm and 1300 nm wavelengths, 1060 nm wavelength OCT was discovered to be an appropriate wavelength range verifying the simultaneously obtainable high-resolution and reasonable depth range visualization of intra-cochlear microstructures. Therefore, the implementation of 1060 nm OCT can minimize the necessity of two distinct OCT systems. Moreover, the results suggest that the performed qualitative and quantitative analysis procedure can be used as a powerful tool to explore further anatomical structures of the cochlea for future studies in otorhinolaryngology.

[1]  J. Fujimoto,et al.  Ultrahigh-resolution ophthalmic optical coherence tomography , 2001, Nature Medicine.

[2]  Tomohiro Kuroda,et al.  Estimation of the Degree of Endolymphatic Hydrops Using Optical Coherence Tomography , 2016 .

[3]  Tatsuya Yamasoba,et al.  Evaluation of the Internal Structure of Normal and Pathological Guinea Pig Cochleae Using Optical Coherence Tomography , 2013, Audiology and Neurotology.

[4]  Zhongping Chen,et al.  Imaging the Internal Structure of the Rat Cochlea Using Optical Coherence Tomography at 0.827 μm and 1.3 μm , 2004 .

[5]  Norihiko Nishizawa,et al.  Quantitative comparison of contrast and imaging depth of ultrahigh-resolution optical coherence tomography images in 800–1700 nm wavelength region , 2012, Biomedical optics express.

[6]  Panomsak Meemon,et al.  Gabor-based fusion technique for Optical Coherence Microscopy. , 2010, Optics express.

[7]  Jeehyun Kim,et al.  Dual-path handheld system for cornea and retina imaging using optical coherence tomography , 2017 .

[8]  R. Klein,et al.  Prevalence of hearing loss in older adults in Beaver Dam, Wisconsin. The Epidemiology of Hearing Loss Study. , 1998, American journal of epidemiology.

[9]  Luigi Ferrucci,et al.  Hearing loss and cognitive decline in older adults: questions and answers , 2014, Aging Clinical and Experimental Research.

[10]  Valery V. Tuchin,et al.  Advanced Biophotonics : Tissue Optical Sectioning , 2013 .

[11]  Norimasa Morita,et al.  Ménière's disease. , 2008, Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology.

[12]  J. Schuman,et al.  Optical coherence tomography. , 2000, Science.

[13]  John S. Oghalai,et al.  Swept source optical coherence tomography for in vivo imaging and vibrometry in the apex of the mouse cochlea , 2015 .

[14]  Ruchire Eranga Wijesinghe,et al.  Decalcification using ethylenediaminetetraacetic acid for clear microstructure imaging of cochlea through optical coherence tomography , 2016, Journal of biomedical optics.

[15]  R I Kitney,et al.  Investigation of acoustic noise on 15 MRI scanners from 0.2 T to 3 T , 2001, Journal of magnetic resonance imaging : JMRI.

[16]  J. Fujimoto,et al.  In vivo endoscopic optical biopsy with optical coherence tomography. , 1997, Science.

[17]  Zhongping Chen,et al.  Optical Coherence Tomography of the Cochlea in the Porcine Model , 2008, The Laryngoscope.

[18]  Jeehyun Kim,et al.  Optical Coherence Tomography for the Diagnosis and Evaluation of Human Otitis Media , 2015, Journal of Korean medical science.

[19]  Dirk Faber,et al.  Functional optical coherence tomography : spatially resolved measurements of optical properties , 2005 .

[20]  Peter Damberg,et al.  Experimental Fusion of Contrast Enhanced High-Field Magnetic Resonance Imaging and High-Resolution Micro-Computed Tomography in Imaging the Mouse Inner Ear , 2015, The open neuroimaging journal.

[21]  Barry Cense,et al.  Advances in optical coherence tomography imaging for dermatology. , 2004, The Journal of investigative dermatology.

[22]  Theo van Walsum,et al.  Quantification of fibrous cap thickness in intracoronary optical coherence tomography with a contour segmentation method based on dynamic programming , 2015, International Journal of Computer Assisted Radiology and Surgery.

[23]  Jeehyun Kim,et al.  Optical sensing method to analyze germination rate of Capsicum annum seeds treated with growth-promoting chemical compounds using optical coherence tomography , 2017, Journal of biomedical optics.

[24]  A. Fercher,et al.  Polarization–Sensitive Optical Coherence Tomography of Dental Structures , 1999, Caries Research.

[25]  Yann Nguyen,et al.  Damage to inner ear structure during cochlear implantation: Correlation between insertion force and radio-histological findings in temporal bone specimens , 2017, Hearing Research.

[26]  Kaiyin Zhang,et al.  A contrastive analysis of laser heating between the human and guinea pig cochlea by numerical simulations , 2016, Biomedical engineering online.

[27]  Yehoash Raphael,et al.  Structure and innervation of the cochlea , 2003, Brain Research Bulletin.

[28]  Zhao Ren,et al.  High-speed, high-resolution Fourier-domain optical coherence tomography system for retinal imaging in the 1060 nm wavelength region. , 2008, Optics letters.

[29]  Jeehyun Kim,et al.  In vivo imaging of middle-ear and inner-ear microstructures of a mouse guided by SD-OCT combined with a surgical microscope. , 2014, Optics express.

[30]  L. Tanoue Computed Tomography — An Increasing Source of Radiation Exposure , 2009 .

[31]  S. Yun,et al.  In vivo optical frequency domain imaging of human retina and choroid. , 2006, Optics express.

[32]  J. Fujimoto,et al.  Optical biopsy and imaging using optical coherence tomography , 1995, Nature Medicine.

[33]  Sharon G. Kujawa,et al.  Cochlear synaptopathy in acquired sensorineural hearing loss: Manifestations and mechanisms , 2017, Hearing Research.

[34]  Janani S. Iyer,et al.  Micro-optical coherence tomography of the mammalian cochlea , 2016, Scientific Reports.

[35]  Nikos Paragios,et al.  Handbook of Mathematical Models in Computer Vision , 2005 .

[36]  Audrey K. Ellerbee,et al.  Noninvasive in vivo imaging reveals differences between tectorial membrane and basilar membrane traveling waves in the mouse cochlea , 2015, Proceedings of the National Academy of Sciences.

[37]  Jeehyun Kim,et al.  Industrial resin inspection for display production using automated fluid-inspection based on multimodal optical detection techniques , 2017 .

[38]  J. Eggermont,et al.  The neuroscience of tinnitus , 2004, Trends in Neurosciences.

[39]  Pil Un Kim,et al.  Optical Inspection and Morphological Analysis of Diospyros kaki Plant Leaves for the Detection of Circular Leaf Spot Disease , 2016, Sensors.

[40]  Jui-che Tsai,et al.  Dental Optical Coherence Tomography , 2013, Sensors.

[41]  Bart Nicolai,et al.  Optical coherence tomography visualizes microstructure of apple peel , 2013 .

[42]  A. Fercher,et al.  In vivo human retinal imaging by Fourier domain optical coherence tomography. , 2002, Journal of biomedical optics.

[43]  Zhongping Chen,et al.  Imaging the internal structure of the guinea pig cochlea using optical coherence tomography at 1310 nm , 2001, SPIE BiOS.

[44]  Boris Hermann,et al.  Mapping choroidal and retinal thickness variation in type 2 diabetes using three-dimensional 1060-nm optical coherence tomography. , 2011, Investigative ophthalmology & visual science.

[45]  Boris Povazay,et al.  Multispectral in vivo three-dimensional optical coherence tomography of human skin. , 2010, Journal of biomedical optics.

[46]  Pil Un Kim,et al.  Fast Industrial Inspection of Optical Thin Film Using Optical Coherence Tomography , 2016, Sensors.

[47]  Jeehyun Kim,et al.  Bio-Photonic Detection and Quantitative Evaluation Method for the Progression of Dental Caries Using Optical Frequency-Domain Imaging Method , 2016, Sensors.

[48]  Jeehyun Kim,et al.  In vivo 3D imaging of the human tympanic membrane using a wide-field diagonal-scanning optical coherence tomography probe. , 2017, Applied optics.

[49]  Emma Brunskill,et al.  Global and regional hearing impairment prevalence: an analysis of 42 studies in 29 countries. , 2013, European journal of public health.

[50]  Bradley W Kesser,et al.  The Child with Hearing Loss. , 2015, Otolaryngologic clinics of North America.

[51]  Benjamin J Vakoc,et al.  Three-dimensional microscopy of the tumor microenvironment in vivo using optical frequency domain imaging , 2009, Nature Medicine.